Dielectric microwave resonators in TE011 cavities for electron paramagnetic resonance spectroscopy

被引:35
作者
Mett, Richard R. [1 ,2 ]
Sidabras, Jason W. [1 ]
Golovina, Iryna S. [3 ]
Hyde, James S. [1 ]
机构
[1] Med Coll Wisconsin, Dept Biophys, Milwaukee, WI 53226 USA
[2] Milwaukee Sch Engn, Milwaukee, WI 53202 USA
[3] NASU, Inst Semicond Phys, UA-03028 Kiev, Ukraine
基金
美国国家卫生研究院;
关键词
D O I
10.1063/1.2976033
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The coupled system of the microwave cylindrical TE011 cavity and the TE01 delta dielectric modes has been analyzed in order to determine the maximum achievable resonator efficiency parameter of a dielectric inserted into a cavity, and whether this value can exceed that of a dedicated TE01 delta mode dielectric resonator. The frequency, Q value, and resonator efficiency parameter Lambda for each mode of the coupled system were calculated as the size of the dielectric was varied. Other output parameters include the relative field magnitudes and phases. Two modes are found: one with fields in the dielectric parallel to the fields in the cavity center and the other with antiparallel fields. Results closely match those from a computer program that solves Maxwell's equations by finite element methods. Depending on the relative natural resonance frequencies of the cavity and dielectric, one mode has a higher Q value and correspondingly lower Lambda than the other. The mode with the higher Q value is preferentially excited by a coupling iris or loop in or near the cavity wall. However, depending on the frequency separation between modes, either can be excited in this way. A relatively narrow optimum is found for the size of the insert that produces maximum signal for both modes simultaneously. It occurs when the self-resonance frequencies of the two resonators are nearly equal. The maximum signal is almost the same as that of the dedicated TE01 delta mode dielectric resonator alone, Lambda congruent to 40 G/W-1/2 at X-band for a KTaO3 crystal. The cavity is analogous to the second stage of a two-stage coupler. In general, there is no electron paramagnetic resonance (EPR) signal benefit by use of a second stage. However, there is a benefit of convenience. A properly designed sample-mounted resonator inserted into a cavity can give EPR signals as large as what one would expect from the dielectric resonator alone. (C) 2008 American Institute of Physics. [DOI: 10.1063/1.2976033]
引用
收藏
页数:8
相关论文
共 23 条
[1]   EFFECT OF PRESSURE ON STATIC DIELECTRIC CONSTANT OF KTAO3 [J].
ABEL, WR .
PHYSICAL REVIEW B, 1971, 4 (08) :2696-&
[2]   Cavities with axially uniform fields for use in electron paramagnetic resonance. II. Free space generalization [J].
Anderson, JR ;
Mett, RR ;
Hyde, JS .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (08) :3027-3037
[3]   ELECTRON-SPIN-RESONANCE AND ENDOR APPLICATIONS OF LOOP GAP RESONATORS WITH DISTRIBUTED CIRCUIT COUPLING [J].
ANDERSON, JR ;
VENTERS, RA ;
BOWMAN, MK ;
TRUE, AE ;
HOFFMAN, BM .
JOURNAL OF MAGNETIC RESONANCE, 1985, 65 (01) :165-168
[4]   Transparent miniature dielectric resonator for electron paramagnetic resonance experiments [J].
Blank, A ;
Stavitski, E ;
Levanon, H ;
Gubaydullin, F .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (05) :2853-2859
[5]   A VERSATILE LOOP GAP RESONATOR PROBE FOR LOW-TEMPERATURE ELECTRON SPIN-ECHO STUDIES [J].
BRITT, RD ;
KLEIN, MP .
JOURNAL OF MAGNETIC RESONANCE, 1987, 74 (03) :535-540
[6]   Novel loop-gap probe head for time-resolved electron paramagnetic resonance at 9.5 GHz [J].
Elger, G ;
Torring, JT ;
Mobius, K .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (10) :3637-3641
[7]   THE LOOP-GAP RESONATOR - A NEW MICROWAVE LUMPED CIRCUIT ELECTRON-SPIN-RESONANCE SAMPLE STRUCTURE [J].
FRONCISZ, W ;
HYDE, JS .
JOURNAL OF MAGNETIC RESONANCE, 1982, 47 (03) :515-521
[8]   Optimization of ferroelectric resonators for enhanced EPR sensitivity [J].
Geifman, I ;
Golovina, I .
CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2005, 26B (01) :46-55
[9]   The use of ferroelectric material for increasing the sensitivity of EPR spectrometers [J].
Geifman, IN ;
Golovina, IS ;
Kofman, VI ;
Zusmanov, ER .
FERROELECTRICS, 1999, 234 (1-4) :81-88
[10]  
Hyde J. S., 1989, ADV EPR APPL BIOL BI, P277