Performance analysis of a low-temperature waste heat-driven adsorption desalination prototype

被引:87
作者
Thu, Kyaw [1 ]
Yanagi, Hideharu [2 ]
Saha, Bidyut Baran [3 ,4 ]
Ng, Kim Choon [2 ]
机构
[1] King Abdullah Univ Sci & Technol, Water Desalinat & Reuse Ctr, Thuwal 239556900, Saudi Arabia
[2] Natl Univ Singapore, Dept Mech Engn, Singapore 117576, Singapore
[3] Kyushu Univ, Interdisciplinary Grad Sch Engn Sci, Kasuga, Fukuoka 8168580, Japan
[4] Kyushu Univ, Int Inst Carbon Neutral Energy Res WPI I2CNER, Nishi Ku, Fukuoka 8190395, Japan
关键词
Adsorption; Desalination; Heat recovery; Waste heat utilization; ION-EXCHANGE; SYSTEM; CYCLE;
D O I
10.1016/j.ijheatmasstransfer.2013.06.053
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper discusses the performance analysis of an advanced adsorption desalination (AD) cycle with an internal heat recovery between the condenser and the evaporator. The AD cycle employs the adsorption-desorption principles to convert sea or brackish water into high-grade potable water with total dissolved solids (TDS) less than 10 ppm (mg/L) utilizing low-temperature heat source. The salient features of the AD cycle are the utilization of low temperature waste heat (typically 55 degrees C to 85 degrees C) with the employment of an environment-friendly silica gel/water pair and the low maintenance as it has no major moving parts other than the pumps and valves. For improved performance of the AD pilot plant, the internal heat recovery scheme between the condenser and evaporator has been implemented with a run-about water circuit between them. The efficacy of the scheme is analyzed in terms of key performance indicators such as the specific daily water production (SDWP) and the performance ratio (PR). Extensive experiments were performed for assorted heat source temperatures ranging from 70 degrees C to 50 degrees C. From the experiments, the SDWP of the AD cycle with the proposed heat recovery scheme is found to be 15 m(3) of water per ton of silica gel that is almost twice that of the yield obtained by a conventional AD cycle for the same operation conditions. Another important finding of AD desalination plant is that the advanced AD cycle could still be operational with an inlet heat source temperature of 50 degrees C and yet achieving a SDWP of 4.3 m(3) - a feat that never seen by any heat-driven cycles. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:662 / 669
页数:8
相关论文
共 49 条
[1]   Theoretical analysis of a water desalination system using low grade solar heat [J].
Al-Kharabsheh, S ;
Goswami, DY .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2004, 126 (02) :774-780
[2]   Analysis of an innovative water desalination system using low-grade solar heat [J].
Al-Kharabsheh, S ;
Goswami, DY .
DESALINATION, 2003, 156 (1-3) :323-332
[3]   Multi-effect distillation plants: state of the art [J].
Al-Shammiri, M ;
Safar, M .
DESALINATION, 1999, 126 (1-3) :45-59
[4]  
Alois Paul, GLOBAL WATER CRISIS
[5]   A study of a new thermal vapor compression multi-effect stack (TVC/MES) low temperature distillation system [J].
Aly, SE .
DESALINATION, 1995, 103 (03) :257-263
[6]  
[Anonymous], 2008, 2 UN WORLD WATER DEV
[7]  
[Anonymous], DES WAT PUR TECHN RO
[8]   Development and optimization of ME-TVC desalination system [J].
Bin Amer, A. O. .
DESALINATION, 2009, 249 (03) :1315-1331
[9]  
Bob J., ELECTRODIALYSIS ED E
[10]  
BOLTO BA, 1984, REACT POLYM, V2, P5, DOI 10.1016/0167-6989(84)90003-5