Speciation analysis of chromium in water samples through sequential combination of dispersive magnetic solid phase extraction using mesoporous amino-functionalized Fe3O4/SiO2 nanoparticles and cloud point extraction

被引:82
作者
Diniz, Kristiany Moreira [1 ]
Teixeira Tarley, Cesar Ricardo [1 ,2 ]
机构
[1] Univ Estadual Londrina, Dept Quim, BR-86051990 Londrina, PR, Brazil
[2] Univ Estadual Campinas UNICAMP, Inst Nacl Ciencia & Tecnol INCT Bioanalit, Inst Quim, Dept Quim Analit, BR-13083970 Campinas, SP, Brazil
关键词
Flame atomic absorption spectrometry; Cr(III)/Cr(VI); Water samples; Factorial design; Preconcentration; ATOMIC-ABSORPTION-SPECTROMETRY; DUAL MINI-COLUMNS; HEAVY-METAL IONS; SPECTROPHOTOMETRIC DETERMINATION; ONLINE PRECONCENTRATION; POLY(METHACRYLIC ACID); CR(III); SYSTEM; CR(VI); SILICA;
D O I
10.1016/j.microc.2015.06.011
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The present paper describes the sequential combination of dispersive magnetic solid phase extraction (DMSPE) with cloud point extraction (CPE) as a new nonchromatographic approach for preconcentration/redox speciation of chromium with FAAS detection. The method is based on sequential preconcentradon of Cr(VI) at pH 5.0 onto mesoporous amino-functionalized Fe3O4/SiO2 nanoparticles followed by cloud point extraction of Cr(III) as metallic complex with 4-(2-thiazolylazo)resorcinol (TAR). The variables that play an important role on the performance of both preconcentration methods were thoroughly optimized by means of factorial design. Under optimized condition, an aliquot of 45.0 mL of sample was preconcentrated onto 25 mg of magnetic nanoparticles during 1 min following the elution with 0.5 mL of 2.5 mot HCl. The supernatant containing Cr(III) was then subjected to CPE procedure, which was accomplished by using thermostatic bath at 90 degrees C during 45 min, 5.8 x 10(-4) mol L-1 TAR and 0.3% (v/v) Triton X-114. The method provided preconcentration factors of 16 and 12 times yielding limits of detection (LOD) and quantification (LOQ) of 1.1 and 3.6 mu g L-1 for Cr(VI) and 3.2 and 10.5 mu g L-1 for Cr(III), respectively. A high tolerance toward potentially interfering ions (cations and anions) and humic acid was observed for the method. Precision (n = 10) of the procedure determined as relative standard deviation (RSD) were, 5.8 and 3.7% for Cr(III) using solutions at 15.0 and 165.0 mu g L-1 and 5.5 and 3.0% for Cr(VI) using solutions at 15.0 and 75.0 mu g L-1 concentrations, respectively. The applicability of method was attested by analysis of water samples yielding good recovery values (91.4-103.5%). The accuracy of method was also checked for biological samples using a certified reference material DORM-3 (Fish Protein Certified Reference Material for Trace Metals). (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:185 / 195
页数:11
相关论文
共 47 条
  • [1] Selective extraction and preconcentration of chromium using Moringa oleifera husks as biosorbent and flame atomic absorption spectrometry
    Alves, Vanessa N.
    Coelho, Nivia M. M.
    [J]. MICROCHEMICAL JOURNAL, 2013, 109 : 16 - 22
  • [2] [Anonymous], 2010, DESIGN ANAL EXPT
  • [3] Sol-gel synthesis and structural characterization of niobium-silicon mixed-oxide nanocomposites
    Aronne, Antonio
    Marenna, Elisa
    Califano, Valeria
    Fanelli, Esther
    Pernice, Pasquale
    Trifuoggi, Marco
    Vergara, Alessandro
    [J]. JOURNAL OF SOL-GEL SCIENCE AND TECHNOLOGY, 2007, 43 (02) : 193 - 204
  • [4] Functionalized silica for heavy metal ions adsorption
    Bois, L
    Bonhommé, A
    Ribes, A
    Pais, B
    Raffin, G
    Tessier, F
    [J]. COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2003, 221 (1-3) : 221 - 230
  • [5] Synthesis, characterization and application of a novel mercapto- and amine-bifunctionalized silica for speciation/sorption of inorganic arsenic prior to inductively coupled plasma mass spectrometric determination
    Boyaci, Ezel
    Cagir, Ali
    Shahwan, Talal
    Eroglu, Ahmet E.
    [J]. TALANTA, 2011, 85 (03) : 1517 - 1525
  • [6] Sequential eluent injection technique as a new approach for the on-line enrichment and speciation of Cr(III) and Cr(VI) species on a single column with FAAS detection
    Chamjangali, M. Arab
    Goudarzi, N.
    Mirheidari, M.
    Bahramian, B.
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2011, 192 (02) : 813 - 821
  • [7] Study of cross-linked poly(methacrylic acid) and polyvinylimidazole as selective adsorbents for on-line preconcentration and redox speciation of chromium with flame atomic absorption spectrometry determination
    Corazza, Marcela Zanetti
    Ribeiro, Emerson Schwingel
    Segatelli, Mariana Gava
    Teixeira Tarley, Cesar Ricardo
    [J]. MICROCHEMICAL JOURNAL, 2014, 117 : 18 - 26
  • [8] From microporous to mesoporous molecular sieve materials and their use in catalysis
    Corma, A
    [J]. CHEMICAL REVIEWS, 1997, 97 (06) : 2373 - 2419
  • [9] Hybrid composites made of multiwalled carbon nanotubes functionalized with Fe3O4 nanoparticles for tissue engineering applications
    Cunha, C.
    Panseri, S.
    Iannazzo, D.
    Piperno, A.
    Pistone, A.
    Fazio, M.
    Russo, A.
    Marcacci, M.
    Galvagno, S.
    [J]. NANOTECHNOLOGY, 2012, 23 (46)
  • [10] Spectrophotometric determination of chromium in steel with 4-(2-thiazolylazo)-resorcinol (TAR) using microwave radiation
    de Carvalho, LS
    Costa, ACS
    Ferreira, SLC
    Teixeira, LSG
    [J]. JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2004, 15 (01) : 153 - 157