The frequency closed-loop control strategy of islanded power systems

被引:12
|
作者
Lin, Xiangning [1 ]
Weng, Hanli [1 ]
Zou, Qing [1 ]
Liu, Pei [1 ]
机构
[1] Huazhong Univ Sci & Technol, Elect Power Secur & High Efficiency Lab, Hubei Wuhanl 430074, Peoples R China
基金
中国国家自然科学基金;
关键词
emergency pick-up step; fine-adjusting step; proportional-integral-differential (PID) closed-loop control; rough-adjusting step; under-frequency loading shedding (UFLS);
D O I
10.1109/TPWRS.2008.920044
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A novel power system frequency control strategy is designed in this paper, which is mainly used to improve the stability of the islanding power system. Detecting the change of circuit breaker status, it is feasible to identify the serious accidents, for instance, a generator outage or disconnection from main grids, and so on. The balanceable power before disturbance and the capacity of the removed power can be used to calculate the power deficiency. Then, appropriate load can be shed adaptively. In the subsequent regulating process, adapting to the various stages of frequency variation, the concepts of rough-adjusting step and fine-adjusting step are proposed to obtain a balance between shedding loads quickly and refining the load shed in every step. The concept of proportional-integral-differential (PID) is introduced to design a closed-loop control strategy to trace frequency variation, with which a balance between restraining the sharp drop of frequency effectively and releasing the reserved system capacity thoroughly can be obtained. Moreover, the frequency recovery curve can be optimized and the dead zone of control during the frequency rising stage can be avoided. Compared with the conventional under-frequency loading shedding (UFLS) schemes, the effectiveness of the control strategy presented has been verified by EMTDC simulation tests.
引用
收藏
页码:796 / 803
页数:8
相关论文
共 50 条
  • [21] A closed-loop control for the power source of the ozonizer
    Hu, CS
    Wang, LQ
    Huang, YS
    Zhang, ZC
    PESC 04: 2004 IEEE 35TH ANNUAL POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-6, CONFERENCE PROCEEDINGS, 2004, : 3984 - 3987
  • [22] Robustness of closed-loop glucose control systems
    Wycilok, Artur
    Mieja, Jaroslaw
    ARCHIVES OF CONTROL SCIENCES, 2023, 33 (03) : 681 - 705
  • [23] Closed-Loop and Robust Control of Quantum Systems
    Chen, Chunlin
    Wang, Lin-Cheng
    Wang, Yuanlong
    SCIENTIFIC WORLD JOURNAL, 2013,
  • [24] A CLOSED-LOOP STRATEGY OF ACTIVE DIFFERENTIAL CLUTCH CONTROL
    Ivanovic, Vladimir
    Deur, Josko
    Hancock, Matthew
    Assadian, Francis
    PROCEEDINGS OF THE ASME DYNAMIC SYSTEMS AND CONTROL CONFERENCE 2009, PTS A AND B, 2010, : 1523 - 1530
  • [25] CLOSED-LOOP CONTROL OF STEPPING MOTOR SYSTEMS
    CLARKSON, PJ
    ACARNLEY, PP
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1988, 24 (04) : 685 - 691
  • [26] CLOSED-LOOP CONTROL FOR ANESTHESIA BREATHING SYSTEMS
    WESTENSKOW, DR
    WALLROTH, CF
    JOURNAL OF CLINICAL MONITORING, 1990, 6 (03): : 249 - 256
  • [27] Frequency-domain closed-loop identification of multivariable systems for feedback control
    Li, W
    Lee, JH
    AICHE JOURNAL, 1996, 42 (10) : 2813 - 2827
  • [28] Closed-loop optimal control strategy for cancer chemotheraphy
    Ramkumar, Barathram
    Naidu, D. Subbaram
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINERING CONGRESS AND EXPOSITION 2007, VOL 9, PTS A-C: MECHANICAL SYSTEMS AND CONTROL, 2008, : 223 - 231
  • [29] FREQUENCY RESPONSE OF CLOSED-LOOP CONTROL SYSTEMS FOR THYRISTOR PULSE CONVERTERS.
    Maznev, A.S.
    Arkhipov, K.A.
    Soviet Electrical Engineering (English Translation of Elektrotekhnika), 1977, 48 (03): : 9 - 12
  • [30] Frequency-domain closed-loop identification of multivariable systems for feedback control
    Auburn Univ, Auburn, United States
    AIChE J, 10 (2813-2827):