Improvement and standardization of disinfection in hospital theatre with ultraviolet-C technology

被引:12
作者
Bosco, R. [1 ]
Cevenini, G. [2 ]
Gambelli, S. [3 ]
Nante, N. [4 ]
Messina, G. [4 ,5 ]
机构
[1] Univ Siena, Post Grad Sch Publ Hlth, Dept Mol & Dev Med, Siena, Italy
[2] Univ Siena, Dept Med Biotechnol, Siena, Italy
[3] Rugani Hosp Monteriggioni, Siena, Italy
[4] Univ Siena, Dept Mol & Dev Med, Siena, Italy
[5] Via Aldo Moro 2, I-53100 Siena, Italy
关键词
UVC; Hospital disinfection; Infection prevention; OPERATING-ROOM; LIGHT; DECONTAMINATION; INFECTION; UV;
D O I
10.1016/j.jhin.2022.07.006
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: The level of disinfection between operating sessions is important to prevent cross-contamination risk in operating theatres. Aim: To assess the difference in microbial contamination between different disinfection levels, before (T0) and after (T1) application of a UVC device (UVC-D). Methods: A cross-sectional study was conducted between December 2019 and August 2020 in a clinic. Three disinfection levels - no disinfection after surgery, after in-between cleaning, and after terminal cleaning - were compared to assess the reduction of microbial presence at T0 and T1 according to the use of UVC-D for 3-5 min per bedside. A total of 260 Petri dishes, divided into a preliminary phase followed by a probabilistic model-driven experiment, were used in three operating theatres, and colony-forming units (cfu) were counted. The Mann-Whitney test was performed in the preliminary phase to establish UVC exposure time. Using the probabilistic model, descriptive statistics and percentage and log10 reduction were calculated. The multivariate analysis of variance (MANOVA) for repeated measures was performed to verify the 95% statistical difference between T0 and T1, combined with the disinfection levels and different operating theatres. Findings: The Mann-Whitney test showed no cfu difference between 3 and 5 min of UVC exposure time; the MANOVA test showed no significant difference between disinfection levels in T0 - T1 cfu reduction with a mean cfu reduction of 72% (95% confidence interval: 61.7-84.9) regardless of the disinfection level applied previously. Conclusion: UVC-D has improved environmental disinfection in all initial conditions. Together with the classic sanitizing procedures already present, it improves and standardizes the level of environmental hygiene. (c) 2022 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:19 / 25
页数:7
相关论文
共 31 条
[1]   Comparison of UVC light and chemicals for disinfection of surfaces in hospital isolation units [J].
Andersen, B. M. ;
Banrud, H. ;
Boe, E. ;
Bjordal, O. ;
Drangsholt, F. .
INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2006, 27 (07) :729-734
[2]   Effectiveness of targeted enhanced terminal room disinfection on hospital-wide acquisition and infection with multidrug-resistant organisms and Clostridium difficile: a secondary analysis of a multicentre cluster randomised controlled trial with crossover design (BETR Disinfection) [J].
Anderson, Deverick J. ;
Moehring, Rebekah W. ;
Weber, David J. ;
Lewis, Sarah S. ;
Chen, Luke F. ;
Schwab, J. Conrad ;
Becherer, Paul ;
Blocker, Michael ;
Triplett, Patricia F. ;
Knelson, Lauren P. ;
Lokhnygina, Yuliya ;
Rutala, William A. ;
Sexton, Daniel J. .
LANCET INFECTIOUS DISEASES, 2018, 18 (08) :845-853
[3]  
[Anonymous], 2003, 146981 ISO EN
[4]  
[Anonymous], 2021, 17141 UNI EN
[5]   Comparative evaluation of operating room terminal cleaning by two methods: Focused multivector ultraviolet (FMUV) versus manual-chemical disinfection [J].
Armellino, Donna ;
Goldstein, Kristine ;
Thomas, Linti ;
Walsh, Thomas J. ;
Petraitis, Vidmantas .
AMERICAN JOURNAL OF INFECTION CONTROL, 2020, 48 (02) :147-152
[6]   First UK trial of Xenex PX-UV, an automated ultraviolet room decontamination device in a clinical haematology and bone marrow transplantation unit [J].
Beal, A. ;
Mahida, N. ;
Staniforth, K. ;
Vaughan, N. ;
Clarke, M. ;
Boswell, T. .
JOURNAL OF HOSPITAL INFECTION, 2016, 93 (02) :164-168
[7]   Evaluation of an Ultraviolet C (UVC) Light-Emitting Device for Disinfection of High Touch Surfaces in Hospital Critical Areas [J].
Casini, Beatrice ;
Tuvo, Benedetta ;
Cristina, Maria Luisa ;
Spagnolo, Anna Maria ;
Totaro, Michele ;
Baggiani, Angelo ;
Privitera, Gaetano Pierpaolo .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2019, 16 (19)
[8]   Influence of pulsed-xenon ultraviolet light-based environmental disinfection on surgical site infections [J].
Catalanotti, Angela ;
Abbe, Dudley ;
Simmons, Sarah ;
Stibich, Mark .
AMERICAN JOURNAL OF INFECTION CONTROL, 2016, 44 (06) :E99-E101
[9]   Evaluation of a pulsed xenon ultraviolet light device for reduction of pathogens with biofilm-forming ability and impact on environmental bioburden in clinical laboratories [J].
Chen, Li-hua ;
Li, Yu ;
Qi, Yong ;
Wang, Shan-ni ;
Gao, Chang-qing ;
Wu, Yong .
PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2020, 29
[10]   Reduction of Particles in the Operating Room Using Ultraviolet Air Disinfection and Recirculation Units [J].
Curtis, Gannon L. ;
Faour, Mhamad ;
Jawad, Michael ;
Klika, Alison K. ;
Barsoum, Wael K. ;
Higuera, Carlos A. .