Performance of a DOI-encoding small animal PET system with monolithic scintillators

被引:10
作者
Carles, M. [1 ]
Lerche, Ch. W. [2 ]
Sanchez, F. [1 ]
Orero, A. [1 ]
Moliner, L. [1 ]
Soriano, A. [1 ]
Benlloch, J. M. [1 ]
机构
[1] Univ Politecn Valencia, Ctr Mixto CSIC, IEMAT, Inst Instrumentac Imagen Mol I3M, Valencia 46020, Spain
[2] Philips Res Europe, Dept Xray Imaging Syst, D-52066 Aachen, Germany
关键词
DOI; PET; Spatial resolution; Continuous scintillators; DEPTH; CRYSTALS; CAMERA;
D O I
10.1016/j.nima.2011.11.021
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
PET systems designed for specific applications require high resolution and sensitivity instrumentation. In dedicated system design smaller ring diameters and deeper crystals are widely used in order to increase the system sensitivity. However, this design increases the parallax error, which degrades the spatial image resolution gradually from the center to the edge of the field-of-view (FOV). Our group has designed a depth of interaction(DOI)-encoding small animal PET system based on monolithic crystals. In this work we investigate the restoration of radial resolution for transaxially off-center sources using the DOI information provided by our system. For this purpose we have designed a support for point like sources adapted to our system geometry that allows a spatial compression and resolution response study. For different point source radial positions along vertical and horizontal axes of a FOV transaxial plane we compare the results obtained by three methods: without DOI information, with the DOI provided by our system and with the assumption that all the gamma-rays interact at half depth of the crystal thickness. Results show an improvement of the mean resolution of 10% with the half thickness assumption and a 16% achieved using the DOI provided by the system. Furthermore, a 10% restoration of the resolution uniformity is obtained using the half depth assumption and an 1.8% restoration using measured DOI. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:317 / 321
页数:5
相关论文
共 10 条
[1]   Scanner calibration of a small animal PET camera based on continuous LSO crystals and flat panel PSPMTs [J].
Benlloch, J. M. ;
Carrilero, V. ;
Gonzalez, A. J. ;
Catret, J. ;
Lerche, Ch. W. ;
Abellan, D. ;
de Quiros, F. Garcia ;
Gimenez, M. ;
Modia, J. ;
Sanchez, F. ;
Pavon, N. ;
Ros, A. ;
Martinez, J. ;
Sebastia, A. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 571 (1-2) :26-29
[2]   Position correction with depth of interaction information for a small animal PET system [J].
Carles, M. ;
Lerche, Ch. W. ;
Sanchez, F. ;
Mora, F. ;
Benlloch, J. M. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 :S176-S180
[3]  
Donkhale P.A., 2006, IEEE T NUCL SCI, VNS-53, P2666
[4]   Depth of interaction detection for γ-ray imaging [J].
Lerche, Ch. W. ;
Doering, M. ;
Ros, A. ;
Herrero, V. ;
Gadea, R. ;
Aliaga, R. J. ;
Colom, R. ;
Mateo, F. ;
Monzo, J. M. ;
Ferrando, N. ;
Toledo, J. F. ;
Martinez, J. D. ;
Sebastia, A. ;
Sanchez, F. ;
Benlloch, J. M. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 600 (03) :624-634
[5]   Depth of γ-ray interaction within continuous crystals from the width of its scintillation light-distribution [J].
Lerche, CW ;
Benlloch, JM ;
Sánchez, F ;
Pavón, N ;
Escat, B ;
Gimenez, EN ;
Fernández, M ;
Torres, I ;
Giménez, M ;
Sebastià, A ;
Martínez, J .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (03) :560-572
[6]   Parallax correction in PET using depth of interaction information [J].
MacDonald, LR ;
Dahlbom, M .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (04) :2232-2237
[7]   A practical block detector for a depth-encoding PET camera [J].
Rogers, JG ;
Moisan, C ;
Hoskinson, EM ;
Andreaco, MS ;
Williams, CW ;
Nutt, R .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (06) :3240-3248
[8]  
Schmand M., 1998, IEEE T NUCL SCI, VNS-45, P934
[9]  
SHEEP LA, 1982, IEEE T MED IMAGING, V1, P113
[10]   Simple charge division readouts for imaging scintillator arrays using a multi-channel PMT [J].
Siegel, S ;
Silverman, RW ;
Shao, YP ;
Cherry, SR .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) :1634-1641