Lossy JPEG compression: easy to compress, hard to compare

被引:21
作者
Fidler, A
Likar, B
Skaleric, U
机构
[1] Univ Ljubljana, Fac Med, Dept Restorat Dent & Endodont, SI-1000 Ljubljana, Slovenia
[2] Univ Ljubljana, Fac Elect Engn, Ljubljana, Slovenia
[3] Univ Ljubljana, Fac Med, Dept Oral Med & Periodontol, SI-1000 Ljubljana, Slovenia
关键词
radiography; dental; digital; data compression;
D O I
10.1259/dmfr/52842661
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To review the literature on lossy compression in dental radiography and to discuss the importance and suitability of the methodology used for evaluation of image compression. Methods: A search of Medline (from 1966 to October 2004) was undertaken with the search expression "(Radiography, dental) and compression". Inclusion criterion was that the reference should be evaluating the effect of lossy image compression on diagnostic accuracy. For all included studies, information ill relation to mode of image acquisition, image content.. image compression, image display, and method of image evaluation was extracted. Results: 12 out of 32 papers were included in the review. The design of these 12 studies was found to vary considerably. Parameters used to express the degree of information loss (DIL) were either or both compression ratio (CR) and compression level (CL). The highest acceptable CR reported in the studies ranged from 3.6% to 15.4%. Furthermore, different CR values were proposed even for the same diagnostic task, for example, for caries diagnosis CR ranged from 6.2% to 11.1%. Conclusion: Lossy image compression can be used in clinical radiology if it does not conflict with national law. However, the acceptable DIL is difficult to express and standardize. CR is probably not suitable to express DIL, because it is image content dependent. CL is also probably not suitable to express DIL because of the lack of compression software standardization.
引用
收藏
页码:67 / 73
页数:7
相关论文
共 40 条
  • [1] [Anonymous], SOC INFORM DISPLAY D
  • [2] [Anonymous], 2000, 1SC ISOIEC JTC
  • [3] Digitisation and display of intra-oral films
    Attaelmanan, A
    Borg, E
    Grondahl, HG
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2000, 29 (02) : 97 - 102
  • [4] Influence of the digital image display monitor on observer performance
    Cederberg, RA
    Frederiksen, NL
    Benson, BW
    Shulman, JD
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 1999, 28 (04) : 203 - 207
  • [5] A novel image quality index using Moran I statistics
    Chen, TJ
    Chuang, KS
    Wu, J
    Chen, SC
    Hwang, IM
    Jan, ML
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (08) : N131 - N137
  • [6] Impact of lossy compression on diagnostic accuracy of radiographs for periapical lesions
    Eraso, FE
    Analoui, M
    Watson, AB
    Rebeschini, R
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2002, 93 (05): : 621 - 625
  • [7] Irreversible compression of medical images
    Erickson, BJ
    [J]. JOURNAL OF DIGITAL IMAGING, 2002, 15 (01) : 5 - 14
  • [8] Evaluation of irreversible compression of digitized posterior-anterior chest radiographs
    Erickson, BJ
    Manduca, A
    Persons, KR
    Earnest, F
    Hartman, TE
    Harms, GF
    Brown, LR
    [J]. JOURNAL OF DIGITAL IMAGING, 1997, 10 (03) : 97 - 102
  • [9] Wavelet compression of medical images
    Erickson, BJ
    Manduca, A
    Palisson, P
    Persons, KR
    Earnest, F
    Savcenko, V
    Hangiandreou, NJ
    [J]. RADIOLOGY, 1998, 206 (03) : 599 - 607
  • [10] *FDA CTR DEV RAD H, 2000, GUID SUBM PREM NOT M