Reoperation for ascending aorta false aneurysm using deep hypothermia and circulatory arrest

被引:11
作者
El Oumeiri, Bachar [1 ]
Louagie, Yves [2 ]
Buche, Michel [2 ]
机构
[1] Univ Erasme, ULB Hop, Dept Cardiac Surg, Brussels, Belgium
[2] Catholic Univ Louvain, Clin Univ UCL Mont Godinne, Dept Cardiovasc & Thorac Surg, Yvoir, Belgium
关键词
Aorta; False aneurysm; Dissection; Hypothermic circulatory arrest; THORACIC AORTA; SURGICAL-TREATMENT; CARDIAC-SURGERY; PSEUDOANEURYSM; STRATEGY; CHEST; ARCH;
D O I
10.1510/icvts.2010.262378
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: Ascending aorta false aneurysms after cardiac surgery are uncommon. Resternotomy is hazardous and may result in massive and uncontrollable hemorrhage if the false aneurysm is entered. Here we report our experience with the use of deep hypothermia and circulatory arrest to avoid this risk. Methods: From March 2000 to December 2007, seven patients (mean age 50 years) were reoperated for an ascending aorta false aneurysm. Three patients had undergone an aortic valve replacement (n=2) or an aortic valve repair (n=1). Three had undergone an ascending aorta replacement with a valved conduit (n=2) or an aortic valve repair (n=1) for type A dissection. One had undergone a coronary artery bypass grafting. Mean delay to reoperation was 133 months (range 22-324 months). Two patients had positive blood cultures (Staphylococcus species). Cardiopulmonary bypass was established by extramediastinal access. Patients were cooled to 18 degrees C. Results: Resternotomy was performed uneventfully under total circulatory arrest in all patients. Four patients underwent an ascending aorta replacement with a valved conduit (n=2) or a dacron conduit (n=2) associated with a mitral valve replacement in one patient. Direct suture was performed in two patients and in one patient the aorta was repaired using a saphenous vein patch. There was one hospital death. Mean follow-up was 53 months (range 14-90 months). Conclusion: Resternotomy under circulatory arrest and deep hypothermia is a safe technique well-adapted to patients with an ascending aorta false aneurysm. (C) 2011 Published by European Association for Cardio-Thoracic Surgery. All rights reserved.
引用
收藏
页码:605 / 608
页数:4
相关论文
共 15 条
[1]   Tuberculous pseudoaneurysms of the aortic arch [J].
Aebert, H ;
Birnbaum, DE .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 125 (02) :411-412
[2]   Surgical treatment of pseudoaneurysm of the thoracic aorta [J].
Atik, Fernando A. ;
Navia, Jose L. ;
Svensson, Lars G. ;
Vega, Pablo Ruda ;
Feng, Jingyuan ;
Brizzio, Mariano E. ;
Gillinov, A. Marc ;
Pettersson, B. Gosta ;
Blackstone, Eugene H. ;
Lytle, Bruce W. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2006, 132 (02) :379-U83
[3]   Reoperation for giant false aneurysm of the thoracic aorta: How to reenter the chest? [J].
Bachet, Jean ;
Pirotte, Manuel ;
Laborde, Francois ;
Guilmet, Daniel .
ANNALS OF THORACIC SURGERY, 2007, 83 (05) :1610-1614
[4]   TREATMENT OF POSTOPERATIVE INFECTION OF ASCENDING AORTA AND TRANSVERSE AORTIC-ARCH, INCLUDING USE OF VIABLE OMENTUM AND MUSCLE FLAPS [J].
COSELLI, JS ;
CRAWFORD, ES ;
WILLIAMS, TW ;
BRADSHAW, MW ;
WIEMER, DR ;
HARRIS, RL ;
SAFI, HJ .
ANNALS OF THORACIC SURGERY, 1990, 50 (06) :868-881
[5]   Management of pseudoaneurysm of the ascending aorta performed under circulatory arrest by port-access [J].
D'Attellis, N ;
Diemont, FF ;
Julia, PL ;
Cardon, C ;
Fabiani, JN .
ANNALS OF THORACIC SURGERY, 2001, 71 (03) :1010-1011
[6]   Repair of aortic false aneurysm using deep hypothermia and circulatory arrest [J].
Dumont, E ;
Carrier, M ;
Cartier, R ;
Pellerin, M ;
Poirier, N ;
Bouchard, D ;
Perrault, LP .
ANNALS OF THORACIC SURGERY, 2004, 78 (01) :117-121
[7]  
FLEISCHAKER RJ, 1964, J THORAC CARDIOV SUR, V47, P289
[8]   Mediastinal false aneurysm after thoracic aortic surgery [J].
Katsumata, T ;
Moorjani, N ;
Vaccari, G ;
Westaby, S .
ANNALS OF THORACIC SURGERY, 2000, 70 (02) :547-552
[9]   Endovascular Therapy of Ascending Thoracic Aorta [J].
Martin Pedrosa, Miguel ;
Cenizo Revuelta, Noelia ;
Gutierrez Alonso, Vicente ;
Gonzalez Fajardo, Jose Antonio ;
Vaquero Puerta, Carlos .
ANNALS OF VASCULAR SURGERY, 2010, 24 (05) :696-698
[10]   Reoperation for false aneurysm of the ascending aorta after its prosthetic replacement: Surgical strategy [J].
Mohammadi, S ;
Bonnet, N ;
Leprince, P ;
Kolsi, M ;
Rama, A ;
Pavie, A ;
Gandjbakhch, L .
ANNALS OF THORACIC SURGERY, 2005, 79 (01) :147-152