Eigenspace Based Minimum Variance Beamforming Applied to Ultrasound Imaging of Acoustically Hard Tissues

被引:86
作者
Mehdizadeh, Saeed [1 ]
Austeng, Andreas [2 ]
Johansen, Tonni F. [1 ]
Holm, Sverre [1 ,2 ]
机构
[1] Norwegian Univ Sci & Technol, Dept Circulat & Med Imaging, N-7491 Trondheim, Norway
[2] Univ Oslo, Dept Informat, N-0316 Oslo, Norway
关键词
Adaptive beamforming; bone; eigenspace; minimum variance; ultrasound; vertebra; MEDICAL ULTRASOUND; ADAPTIVE BEAMFORMER; PERFORMANCE; IMAGES; SPECKLE;
D O I
10.1109/TMI.2012.2208469
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Minimum variance (MV) based beamforming techniques have been successfully applied to medical ultrasound imaging. These adaptive methods offer higher lateral resolution, lower sidelobes, and better definition of edges compared to delay and sum beamforming (DAS). In standard medical ultrasound, the bone surface is often visualized poorly, and the boundaries region appears unclear. This may happen due to fundamental limitations of the DAS beamformer, and different artifacts due to, e. g., specular reflection, and shadowing. The latter can degrade the robustness of the MV beamformers as the statistics across the imaging aperture is violated because of the obstruction of the imaging beams. In this study, we employ forward/backward averaging to improve the robustness of the MV beamforming techniques. Further, we use an eigen-spaced minimum variance technique (ESMV) to enhance the edge detection of hard tissues. In simulation, in vitro, and in vivo studies, we show that performance of the ESMV beamformer depends on estimation of the signal subspace rank. The lower ranks of the signal subspace can enhance edges and reduce noise in ultrasound images but the speckle pattern can be distorted.
引用
收藏
页码:1912 / 1921
页数:10
相关论文
共 41 条
[1]  
Amin Devin V, 2003, Comput Aided Surg, V8, P1, DOI 10.3109/10929080309146097
[2]  
[Anonymous], MED BIOL ENG COMP
[3]   Ultrasound using the transverse approach to the lumbar spine provides reliable landmarks for labor epidurals [J].
Arzola, Cristian ;
Davies, Sharon ;
Rofaeel, Ayman ;
Carvalho, Jose C. A. .
ANESTHESIA AND ANALGESIA, 2007, 104 (05) :1188-1192
[4]   Contrast Enhancement and Robustness Improvement of Adaptive Ultrasound Imaging Using Forward-Backward Minimum Variance Beamforming [J].
Asl, Babak Mohammadzadeh ;
Mahloojifar, Ali .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2011, 58 (04) :858-867
[5]   Eigenspace-Based Minimum Variance Beamforming Applied to Medical Ultrasound Imaging [J].
Asl, Babak Mohammadzadeh ;
Mahloojifar, Ali .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2010, 57 (11) :2381-2390
[6]  
Brendel B, 2002, Comput Aided Surg, V7, P146, DOI 10.1002/igs.10038
[7]   HIGH-RESOLUTION FREQUENCY-WAVENUMBER SPECTRUM ANALYSIS [J].
CAPON, J .
PROCEEDINGS OF THE IEEE, 1969, 57 (08) :1408-&
[8]   PERFORMANCE OF DMI AND EIGENSPACE-BASED BEAMFORMERS [J].
CHANG, L ;
YEH, CC .
IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 1992, 40 (11) :1336-1347
[9]   Diagnosis and guided reduction of forearm fractures in children using bedside ultrasound [J].
Chen, Lei ;
Kim, Yunie ;
Moore, Christopher L. .
PEDIATRIC EMERGENCY CARE, 2007, 23 (08) :528-531
[10]  
Featherstone W., 1997, ANTENNAS PROPAG, V1, P322