Magnetic Resonance Imaging of the Brain Using Compressed Sensing - Quality Assessment in Daily Clinical Routine

被引:41
作者
Moench, Sebastian [1 ]
Sollmann, Nico [1 ]
Hock, Andreas [2 ]
Zimmer, Claus [1 ]
Kirschke, Jan S. [1 ]
Hedderich, Dennis M. [1 ]
机构
[1] Tech Univ Munich, Dept Diagnost & Intervent Neuroradiol, Klinikum Rechts Isar, Ismaninger Str 22, D-81675 Munich, Germany
[2] Philips AG, Horgen, Switzerland
基金
欧洲研究理事会; 欧盟地平线“2020”;
关键词
Compressed sensing; Clinical quality assessment; Accelerated imaging; Magnetic resonance imaging; Parallel imaging; MRI;
D O I
10.1007/s00062-019-00789-x
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose To assess the effect of compressed sensing (CS) on image quality and acquisition speed in routine brain magnetic resonance imaging (MRI). Methods During a 2-month implementation period of CS, two senior neuroradiologists, one MRI physicist and one application specialist optimized the CS acceleration factor to reduce scan time and improve spatial resolution, while maintaining image quality. Afterwards, two neuroradiologists independently scored image quality on a 5-point Likert scale in 3-dimensional (3D) fluid attenuation inversion recovery (FLAIR), 3D double inversion recovery (DIR), 3D T2, 3D T1, 3D T1 + gadoteric acid, axial T2, axial FLAIR, axial T2*, and 3D arterial time-of-flight MR angiography (art. TOF) sequences acquired during 1 week before (CS-) and after (CS+) the implementation of CS. Time of acquisition was recorded for all sequences. Results A total of 51 CS- and 48 CS+ patients were included. The median scan time reduction was 29.3% (range 0.0-58.4%), median voxel size reduction was 10.5% (0.0-33.3%). The CS+ image quality was rated superior for 3D FLAIR (p < 0.001), 3D T2 (p = 0.001), and axial T2* sequences (p = 0.024). For all other sequences, no statistical difference in image quality was observed. Interreader agreement regarding image quality was good for all sequences (weighted Cohen's kappa > 0.5). Conclusion The use of CS saves considerable imaging time while allowing to increase spatial resolution in routine clinical brain MRI without loss in image quality.
引用
收藏
页码:279 / 286
页数:8
相关论文
共 24 条
[1]   Accelerated Noncontrast-Enhanced Pulmonary Vein MRA With Distributed Compressed Sensing [J].
Akcakaya, Mehmet ;
Hu, Peng ;
Chuang, Michael L. ;
Hauser, Thomas H. ;
Ngo, Long H. ;
Manning, Warren J. ;
Tarokh, Vahid ;
Nezafat, Reza .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (05) :1248-1255
[2]   Accelerated MRI for the assessment of cardiac function [J].
Axel, Leon ;
Otazo, Ricardo .
BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1063)
[3]   MR imaging of the ankle at 3 Tesla and 1.5 Tesla: protocol optimization and application to cartilage, ligament and tendon pathology in cadaver specimens [J].
Barr, Cameron ;
Bauer, Jan S. ;
Malfair, David ;
Ma, Benjamin ;
Henning, Tobias D. ;
Steinbach, Lynne ;
Link, Thomas M. .
EUROPEAN RADIOLOGY, 2007, 17 (06) :1518-1528
[4]   Accelerated MRI of the Lumbar Spine Using Compressed Sensing: Quality and Efficiency [J].
Bratke, Grischa ;
Rau, Robert ;
Weiss, Kilian ;
Kabbasch, Christoph ;
Sircar, Krishnan ;
Morelli, John N. ;
Persigehl, Thorsten ;
Maintz, David ;
Giese, Daniel ;
Haneder, Stefan .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 49 (07) :E164-E175
[5]   Free-Breathing Contrast-Enhanced Multiphase MRI of the Liver Using a Combination of Compressed Sensing, Parallel Imaging, and Golden-Angle Radial Sampling [J].
Chandarana, Hersh ;
Feng, Li ;
Block, Tobias K. ;
Rosenkrantz, Andrew B. ;
Lim, Ruth P. ;
Babb, James S. ;
Sodickson, Daniel K. ;
Otazo, Ricardo .
INVESTIGATIVE RADIOLOGY, 2013, 48 (01) :10-16
[6]   Compressed sensing [J].
Donoho, DL .
IEEE TRANSACTIONS ON INFORMATION THEORY, 2006, 52 (04) :1289-1306
[7]   Acceleration of Double Inversion Recovery Sequences in Multiple Sclerosis With Compressed Sensing [J].
Eichinger, Paul ;
Hock, Andreas ;
Schoen, Simon ;
Preibisch, Christine ;
Kirschke, Jan S. ;
Muehlau, Mark ;
Zimmer, Claus ;
Wiestler, Benedikt .
INVESTIGATIVE RADIOLOGY, 2019, 54 (06) :319-324
[8]   Compressed sensing for body MRI [J].
Feng, Li ;
Benkert, Thomas ;
Block, Kai Tobias ;
Sodickson, Daniel K. ;
Otazo, Ricardo ;
Chandarana, Hersh .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 45 (04) :966-987
[9]  
Geerts-Ossevoort L., 2018, PHILIPS FIELDSTRENGT
[10]  
Geethanath Sairam, 2013, Critical Reviews in Biomedical Engineering, V41, P183