Label-free capacitive immunosensor for microcystin-LR using self-assembled thiourea monolayer incorporated with Ag nanoparticles on gold electrode

被引:115
作者
Loyprasert, Suchera [1 ,2 ]
Thavarungkul, Panote [2 ,3 ]
Asawatreratanakul, Punnee [2 ,4 ]
Wongkittisuksa, Booncharoen [2 ,5 ]
Limsakul, Chusak [2 ,5 ]
Kanatharana, Proespichaya [1 ,2 ]
机构
[1] Prince Songkla Univ, Fac Sci, Dept Chem, Hat Yai 90112, Songkhla, Thailand
[2] Prince Songkla Univ, Trace Anal & Biosensor Res Ctr, Hat Yai 90112, Songkhla, Thailand
[3] Prince Songkla Univ, Fac Sci, Dept Phys, Hat Yai 90112, Songkhla, Thailand
[4] Prince Songkla Univ, Fac Sci, Dept Biochem, Hat Yai 90112, Songkhla, Thailand
[5] Prince Songkla Univ, Fac Engn, Dept Elect Engn, Hat Yai 90112, Songkhla, Thailand
关键词
label-free immunosensor; self-assembled monolayer; Ag nanoparticle; microcystin-LR; capacitance measurement;
D O I
10.1016/j.bios.2008.03.016
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A label-free immunosensor based on a modified gold electrode incorporated with silver(Ag) nanoparticles (NPs) to enhance the capacitive response to microcystin-LR (MCLR) has been developed Anti-microcystin-LR (anti-MCLR) was immobilized on silver nanoparticles bound to a self-assembled thiourea monolayer Interaction ofanti-MCLR and MCLR were directly detected by capacitance measurement. Under optimum conditions, MCLR could be determined with a detection limit of 7.0 pg l(-1) and linearity between 10 pg l(-1) and 1 mu g l(-1). The immobilized anti-MUR oil self-assembled thiourea monolayer incorporated with silver nanoparticles was stable and good reproducibility of the signal could be obtained up to 43 times with an R.S.D. of 2.1%. Comparing to the modified electrode without silver nanoparticles it gave 1.7-fold higher sensitivity and lower limit of detection. The developed immunosensor was applied to analyze MCLR in water samples and the results were in good agreement with those obtained by high-performance liquid chromatography (HPLC) (P < 0.05). (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:78 / 86
页数:9
相关论文
共 55 条
[1]  
Andersson K, 1999, J MOL RECOGNIT, V12, P310, DOI 10.1002/(SICI)1099-1352(199909/10)12:5<310::AID-JMR470>3.0.CO
[2]  
2-5
[3]   Identification and optimization of regeneration conditions for affinity-based biosensor assays.: A multivariate cocktail approach [J].
Andersson, K ;
Hämäläinen, M ;
Malmqvist, M .
ANALYTICAL CHEMISTRY, 1999, 71 (13) :2475-2481
[4]  
[Anonymous], 2006, R LANG ENV STAT COMP
[5]  
[Anonymous], [No title captured]
[6]   Determination of microcystin variants and related peptides present in a water bloom of Planktothrix (Oscillatoria) rubescens in a Spanish drinking water reservoir by LC/ESI-MS [J].
Barco, M ;
Flores, C ;
Rivera, J ;
Caixach, J .
TOXICON, 2004, 44 (08) :881-886
[7]  
Bell S.G., 1994, REV MED MICROBIOL, V5, P256, DOI DOI 10.1097/00013542-199410000-00005
[8]   An immunological interleukin-6 capacitive biosensor using perturbation with a potentiostatic step [J].
Berggren, C ;
Bjarnason, B ;
Johansson, G .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (10) :1061-1068
[9]  
Berggren C, 2001, ELECTROANAL, V13, P173, DOI 10.1002/1521-4109(200103)13:3<173::AID-ELAN173>3.0.CO
[10]  
2-B