Analysis of the performance of a tankless water heating combo system: Space heating only mode

被引:4
作者
Der, Joseph P. [1 ]
Kostiuk, Larry W. [1 ]
McDonald, Andre G. [1 ]
机构
[1] Univ Alberta, Donadeo Innovat Ctr Engn 10 203, Dept Mech Engn, Edmonton, AB T6G 1H9, Canada
关键词
Combination system; Heat transfer; Heating; Ventilation and air conditioning (HVAC); Hydronic air heater; Space heating; Tankless water heater; HEATERS; ENERGY;
D O I
10.1016/j.enbuild.2016.12.020
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Advancements in water heating and control technology have improved the performance of tankless water heaters in recent years. A tankless water heater coupled with a hydronic air-handling unit functions as a novel system known as a combination system that is used for residential space heating. To quantify the effect of the outlet water temperature from the water heater on the time-averaged thermal efficiency of a tankless water heater-hydronic heater combo system, an experimental method was developed. With the experimental assembly, it was found that the thermal efficiency of the tankless water heater during space heating varied monotonically between 39% and 95% for outlet water temperatures settings respectively between 38 C and 60 degrees C. Energy losses from the flue gases represented 3%-47% of the total energy that was supplied to the system for the same respective outlet water temperature settings. An exergy analysis of the air handling Unit was performed and results are presented. The results suggest tankless water heaterhydronic air heater combo systems can be an efficient configuration for space heating at tankless heater outlet water temperature settings of 60 degrees C. Water temperature settings below 60 degrees C produced transient variations, including cycling, in the system that became important and system performance deteriorated. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 12
页数:12
相关论文
共 20 条
[1]  
[Anonymous], 2012, INTRO THERMO FLUID S, P223
[2]  
[Anonymous], 2011, P911 CSA
[3]   Performance of gas tankless (instantaneous) water heaters under various international standards [J].
Bourke, Grant ;
Bansal, Pradeep ;
Raine, Robert .
APPLIED ENERGY, 2014, 131 :468-478
[4]  
Burch J., 2008, AM SOL EN SOC ANN C, P1
[5]  
Butcher T, 2011, ASHRAE J, V53, P36
[6]  
Dieckmann J, 2009, ASHRAE J, V51, P117
[7]   Exergetic efficiency of heat exchangers [J].
Evenko, VI .
CHEMICAL AND PETROLEUM ENGINEERING, 1996, 32 (01) :37-42
[8]  
Glanville P., 2013, ASHRAE T, V119, P1
[9]  
Grant P., 2011, ASME 2011 5 INT C EN, P1035
[10]   Exergetic modeling and performance evaluation of solar water heating systems for building applications [J].
Gunerhan, Huseyin ;
Hepbasli, Arif .
ENERGY AND BUILDINGS, 2007, 39 (05) :509-516