Fault Diagnosis and Condition Division Criterion of DC Gas Insulating Equipment Based on SF6 Partial Discharge Decomposition Characteristics

被引:20
|
作者
Zeng, Fuping [1 ]
Wu, Siying [1 ]
Yang, Xu [1 ,2 ]
Wan, Zhaofeng [1 ]
Tang, Ju [1 ]
Zhang, Mingxuan [1 ]
Yao, Qiang [3 ]
机构
[1] Wuhan Univ, Sch Elect Engn, Wuhan 430072, Hubei, Peoples R China
[2] Wuhan NARI Ltd Co, State Grid Elect Power Res Inst, Wuhan 430074, Hubei, Peoples R China
[3] Chongqing Power Co, Chongqing Elect Power Res Inst, Chongqing 401123, Peoples R China
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
Negative DC; SF6 decomposition characteristics; minimum-redundancy-maximum-relevance; fault diagnosis; decision tree; condition evaluation; MUTUAL INFORMATION; FEATURE-EXTRACTION; RECOGNITION; SELECTION; CORONA; COMPONENTS; TRANSFORM;
D O I
10.1109/ACCESS.2019.2902413
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
SF6 decomposition characteristics directly reflect the generation, development, and evolution of internal faults in gas-insulated equipment (GIE). However, establishing the DC-GIE internal insulation condition comprehensive division criterion and fault diagnosis method based on SF6 decomposition characteristics remains unsolved. Therefore, partial discharge (PD) and SF6 decomposition characteristics of typical insulation defects from initial discharge to the breakdown process are discussed in this paper. The average discharge magnitude in a second Q(sec) is selected as an electrical feature to characterize the PD condition, and the PD state is divided into three levels, namely, mild PD, medium PD, and severe PD. SF6 decomposition experiments are conducted under different PD conditions of each defect, and the SF6 decomposition characteristics under different failure conditions are obtained. On this basis, we construct five feature sets of 36 characteristic quantities for GIE PD fault diagnosis and analyze the validity. A minimum-redundancy-maximum-relevance-based feature selection algorithm is used to optimize the characteristic quantities, and an optimal feature set is selected, i.e., {C(SO2)/C(T), C(SOF2)/C(CT), C(SO2F2)/C(ST)}. The characteristic quantities of SF6 decomposition component, which characterizes PD condition, are reconstructed, and the component characteristic criterion of PD condition division is proposed. Thus, a decision tree evaluation model for the PD condition of the typical insulation defect inside DC-GIE is constructed. This paper lays a foundation for the insulation condition evaluation and fault diagnosis of DC-GIE.
引用
收藏
页码:29869 / 29881
页数:13
相关论文
共 50 条
  • [41] SF6 Partial Discharge Decomposition Characteristics Under Different Lengths of Wire-Type Metal Particles in Direct Current Gas Insulated Equipment
    Gang Wei
    Zhengqin Cao
    Yongjian Zhou
    Yichun Bai
    Ding-Wen Hu
    Journal of Electrical Engineering & Technology, 2021, 16 : 975 - 983
  • [42] Partial Discharge Characteristics of SF6 and SF6/N2 in Nonuniform Electric Field Under Negative DC Voltage
    Han, Xutao
    Zhang, Xuanrui
    Wang, Haotian
    Sun, Yuan
    Zhou, Yang
    Li, Junhao
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2023, 30 (01) : 131 - 138
  • [43] Design and optimization of photoacoustic CO gas sensor for fault diagnosis of SF6 gas insulated equipment
    Yin Xu-Kun
    Dong Lei
    Wu Hong-Peng
    Liu Li-Xian
    Shao Xiao-Peng
    ACTA PHYSICA SINICA, 2021, 70 (17)
  • [44] GIS Insulation Fault Diagnosis based on Detection of SF6 decomposition Products
    Dai, Dangdang
    Wang, Xianpei
    Zhao, Yu
    Zhang, Ying
    Zhang, Jun
    PROCEEDINGS OF 2017 9TH INTERNATIONAL CONFERENCE ON MEASURING TECHNOLOGY AND MECHATRONICS AUTOMATION (ICMTMA), 2017, : 60 - 67
  • [45] Partial discharge and breakdown characteristics of CO2-based gas mixtures as SF6 substitutes
    Koshino, N
    Yoshitake, Y
    Hayakawa, N
    Okubo, H
    GASEOUS DIELECTRICS X, 2004, : 217 - 222
  • [46] Influence and mechanism of pressure on SF6 decomposition components of gas-insulated switchgear under positive DC partial discharge
    Cao, Zhengqin
    Tang, Ju
    Miao, Yulong
    Zhu, Ning
    Yao, Qiang
    Zeng, Fuping
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2018, 13 (08) : 1136 - 1141
  • [47] Characteristics and Development Mechanisms of Partial Discharge in SF6 Gas Under Impulse Voltages
    Zhao, Xuefeng
    Yao, Xiu
    Guo, Zhifeng
    Li, Junhao
    Si, Wenrong
    Li, Yanming
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2011, 39 (02) : 668 - 674
  • [48] Partial Discharge Characteristics for Small Gap of Electrode/Epoxy Interface in SF6 Gas
    Mansour, D. A.
    Kojima, H.
    Hayakawa, N.
    Endo, F.
    Okubo, H.
    2008 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2008, : 486 - 489
  • [49] Partial Discharge Characteristics and Mechanism in SF6 Gas under Oscillating Impulse Voltages
    Zhao, Xuefeng
    Pu, Lu
    Ren, Shuangzan
    Ju, Zeli
    Zhao, Wenyan
    2016 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (CMD), 2016, : 839 - 842
  • [50] Insulation lifetime characteristics of polyamid films by partial discharge under SF6 gas
    Sun, JH
    Kim, WS
    Kim, KH
    PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1 & 2, 2000, : 165 - 168