Numerical study and experimental validation of the effects of orientation and configuration on melting in a latent heat thermal storage unit

被引:93
作者
Mahdi, Mustafa S. [1 ]
Hasan, Ahmed F. [1 ]
Mahood, Hameed B. [2 ]
Campbell, Alasdair N. [2 ]
Khadom, Anees A. [1 ]
Karim, Abdul Mun'em A. [1 ]
Sharif, Adel O. [2 ]
机构
[1] Univ Diyala, Dept Chem Engn, Coll Engn, Diyala 32001, Iraq
[2] Univ Surrey, Fac Engn & Phys Sci, Dept Chem & Proc Engn, Guildford, Surrey, England
关键词
Thermal energy storage; PCM; Orientation and configuration; Fins; CFD; SHELL-AND-TUBE; PHASE-CHANGE MATERIAL; ENERGY-STORAGE; PERFORMANCE ANALYSIS; PARAFFIN WAX; PCM; SOLIDIFICATION; BEHAVIOR; SYSTEM; FINS;
D O I
10.1016/j.est.2019.04.013
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Enhancing the effectiveness of solar power, including daytime storage for overnight use, is essential to reduce fossil fuel usage. This work explores the melting behaviour of paraffin wax in shell and tube latent heat thermal storage unit (LHSU) in different configurations and orientations. Numerical simulation were carried out and compared with experimental measurements for non-finned and finned configurations arranged vertically during the melting (charging) process. A commercial paraffin wax was used as a phase change material (PCM). The temperature and liquid fraction of the PCM during the course of the melting process in both configurations were used for model validation. When considering the liquid fraction, the numerical results showed excellent qualitative agreement with the experimental images for all the cases being studied. Specifically, the shape and progress of the melting front showed good agreement between the experiments and numerical results. Furthermore, the model predicted well the experimentally measured temperature in the melting PCM, with a maximum average discrepancy of 3.6%. The validated model was then used to investigate different process configurations. The results indicated that the addition of fins enhanced the melting process by an average of 50%. The non-finned tubes had a superior melting rate in the horizontal orientation over the vertical orientation, while orientation was found to have only a minor impact on the melting process with finned tubes.
引用
收藏
页码:456 / 468
页数:13
相关论文
共 50 条
  • [1] Geometric and design parameters of fins employed for enhancing thermal energy storage systems: a review
    Abdulateef, Ammar M.
    Mat, Sohif
    Abdulateef, Jasim
    Sopian, Kamaruzzaman
    Al-Abidi, Abduljalil A.
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2018, 82 : 1620 - 1635
  • [2] Experimental and computational study of melting phase-change material in a triplex tube heat exchanger with longitudinal/triangular fins
    Abdulateef, Ammar M.
    Mat, Sohif
    Sopian, Kamaruzzaman
    Abdulateef, Jasim
    Gitan, Ali A.
    [J]. SOLAR ENERGY, 2017, 155 : 142 - 153
  • [3] Experimental comparison of longitudinal and annular fins using PCM for Thermal energy storage
    Afridi, Mohammed Shahid
    Anthony, Alfred
    Sundaram, P.
    Babu, Sunil
    [J]. 2ND INTERNATIONAL CONFERENCE ON ADVANCES IN MECHANICAL ENGINEERING (ICAME 2018), 2018, 402
  • [4] An experimental investigation of shell and tube latent heat storage for solar dryer using paraffin wax as heat storage material
    Agarwal, Ashish
    Sarviya, R. M.
    [J]. ENGINEERING SCIENCE AND TECHNOLOGY-AN INTERNATIONAL JOURNAL-JESTECH, 2016, 19 (01): : 619 - 631
  • [5] Experimental study on melting/solidification characteristics of a paraffin as PCM
    Akgun, Mithat
    Aydin, Orhan
    Kaygusuz, Kamil
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2007, 48 (02) : 669 - 678
  • [6] An overview of thermal energy storage systems
    Alva, Guruprasad
    Lin, Yaxue
    Fang, Guiyin
    [J]. ENERGY, 2018, 144 : 341 - 378
  • [7] Experimental investigation and comparative performance analysis of a compact finned-tube heat exchanger uniformly filled with a phase change material for thermal energy storage
    Amagour, Mohamed El Habib
    Rachek, Adil
    Bennajah, Mounir
    Touhami, Mohamed Ebn
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2018, 165 : 137 - 151
  • [8] HEAT-TRANSFER IN LAMINAR-FLOW WITH A PHASE-CHANGE BOUNDARY
    ASGARPOUR, S
    BAYAZITOGLU, Y
    [J]. JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1982, 104 (04): : 678 - 682
  • [9] BRENT AD, 1988, NUMER HEAT TRANSFER, V13, P297, DOI 10.1080/10407788808913615
  • [10] Oscillatory and nonoscillatory behavior of a simple model for cool flames, Sal'nikov's reaction, P → A → B, occurring in a spherical batch reactor with varying intensities of natural convection
    Campbell, A. N.
    Cardoso, S. S. S.
    Hayhurst, A. N.
    [J]. COMBUSTION AND FLAME, 2008, 154 (1-2) : 122 - 142