A robust sensor platform for label-free detection of anti-Salmonella antibodies using undiluted animal sera

被引:18
作者
Ewald, Melanie [1 ]
Le Blanc, Alexander Fabian [1 ]
Gauglitz, Gunter [1 ]
Proll, Guenther [1 ]
机构
[1] Univ Tubingen, Inst Phys & Theoret Chem, D-72076 Tubingen, Germany
关键词
1-lambda-Reflectometry; RIfS; Label-free; Salmonella infection; Optical Sensors; Biosensor; CHEMICAL-STRUCTURE; CONSTANTS; SURFACE; MARKER; PIGS;
D O I
10.1007/s00216-013-7040-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We present a portable and easy-to-use biosensor platform, allowing for label-free detection of diagnostic markers in undiluted animal serum. Exemplarily, this is shown for the detection of anti-Salmonella antibodies. 1-lambda-Reflectometry was used as detection method, making the new biosensor platform portable, cheap, and robust. As recognition elements, lipopolysaccharides (LPSs) from Salmonella typhimurium bacteria were immobilized as sensitive layer on the transducer to carry out serological tests via a direct assay format. For this purpose, a new surface preparation protocol has been worked out allowing for immobilization of the LPS via hydrophobic interactions. It has been shown that results obtained by 1-lambda-Reflectometry are equivalent to those obtained by the non-portable Reflectometric Interference Spectroscopy setup. The new sensor platform was calibrated in both matrices, buffer and undiluted serum. Good sensitivity, selectivity and intra chip reproducibility have been observed. Furthermore, inter chip reproducibility was examined and recovery rates were found to be between 99 and 117 % in undiluted serum.
引用
收藏
页码:6461 / 6469
页数:9
相关论文
共 26 条
[1]   Label-free quantification of cystatin C as an improved marker for renal failure [J].
Bleher, Oliver ;
Ehni, Markus ;
Gauglitz, Guenter .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 402 (01) :349-356
[2]   DIRECT MONITORING OF ANTIGEN-ANTIBODY INTERACTIONS BY SPECTRAL INTERFEROMETRY [J].
BRECHT, A ;
INGENHOFF, J ;
GAUGLITZ, G .
SENSORS AND ACTUATORS B-CHEMICAL, 1992, 6 (1-3) :96-100
[3]  
BRECHT A, 1992, ANALUSIS, V20, P135
[4]  
DUDLEY RA, 1985, CLIN CHEM, V31, P1264
[5]  
EDDOWES MJ, 1987, BIOSENSORS, V3, P1
[6]  
Ewald M, 2012, GIT LABOR FACHZ, V56, P596
[7]   Handheld and portable test systems for immunodiagnostics, nucleic acid detection and more [J].
Faulstich, Konrad ;
Haberstroh, Klaus ;
Gruler, Roman ;
Eberhard, Michael ;
Wiest, Thomas ;
Lentzsch, Dirk .
OPTICS AND PHOTONICS IN GLOBAL HOMELAND SECURITY IV, 2008, 6945
[8]   Kinetic analysis of the estrogen receptor alpha using RIfS [J].
Fechner, Peter ;
Proell, Florian ;
Albrecht, Christiane ;
Gauglitz, Guenter .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (03) :729-735
[9]   A biomimetic sensor surface to detect anti-β2-glycoprotein-I antibodies as a marker for antiphospholipid syndrome [J].
Hilbig, Urs ;
Bleher, Oliver ;
Le Blanc, Alexander ;
Gauglitz, Guenter .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 403 (03) :713-717
[10]  
Joensson U, 1991, BIOTECHNIQUES, V11, P624