Fitting Algorithm for Power Tower Grounding Resistance with Vertical Layered Soil Model

被引:0
|
作者
Huang Ying [1 ]
Tang Bo [1 ]
Qu Zihang [1 ]
Chen Bin [1 ]
机构
[1] Three Gorges Univ, Coll Elect Engn & New Energy, Yichang 443002, Peoples R China
关键词
vertical layered soil; power transmission line; tower grounding resistance; regulation calculation method; Green Function; least squares fitting methods;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The accurate algorithm, which is used in the calculation of tower grounding resistance of power line in vertical layered soil, is difficult for normal engineering personnel to handle. Based on Green function, the resistance of typical tower grounding device is calculated. Therefore, the fitting function, which represents the relationship between resistivity of vertical layered soil and resistance values of grounding device, is deduced with the hyperbolic function as a fitting function using the least squares curve fitting methods. At last, the fitting formula of tower grounding resistance with the vertical layered soil model is acquired. According to the precision analysis, it is found that the accuracy of proposed formula is related with the initial value, but its maximum error does not exceed 10%.
引用
收藏
页码:676 / 680
页数:5
相关论文
共 47 条
  • [1] Fitting algorithm of transmission tower grounding resistance in vertically layered soil models
    Tang, Bo
    Huang, Ying
    Liu, Ren
    Wu, Zhuo
    Qu, Zihang
    ELECTRIC POWER SYSTEMS RESEARCH, 2016, 139 : 121 - 126
  • [2] Grounding resistance measurement analysis of grounding system in vertical-layered soil
    Zeng, R
    He, JL
    Gao, YQ
    Zou, J
    Guan, ZC
    IEEE TRANSACTIONS ON POWER DELIVERY, 2004, 19 (04) : 1553 - 1559
  • [3] Measuring electrode arrangement for grounding resistance measurement of grounding system in vertical-layered soil
    Zeng, R
    He, JL
    Gao, YQ
    Sun, WM
    Su, Q
    2000 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS I-III, PROCEEDINGS, 2000, : 1469 - 1474
  • [4] Algorithm Research on Tower Grounding Resistance On-line Measurement
    Wang, Tao
    Li, Bing
    Yang, Hongxing
    MEASUREMENT TECHNOLOGY AND ITS APPLICATION, PTS 1 AND 2, 2013, 239-240 : 372 - 375
  • [5] Power Frequency Interference and Suppression in Measurement of Power Transmission Tower Grounding Resistance
    Zhou, Wenjun
    Liu, Yushun
    Li, Gongxin
    Yan, Guozhi
    Yang, Shuai
    Li, Han
    Zhou, Chengke
    Su, Charles Qi
    IEEE TRANSACTIONS ON POWER DELIVERY, 2015, 30 (02) : 1016 - 1023
  • [6] METHOD OF ESTIMATING THE GROUNDING RESISTANCE OF POWER TRANSMISSION TOWER FOUNDATION.
    Noda, Masanobu
    Kinoshita, Hitoshi
    Matsubara, Ichiro
    Electrical Engineering in Japan (English translation of Denki Gakkai Ronbunshi), 1987, 107 (04): : 68 - 76
  • [7] Optimization Research on Grounding Resistance of Power Transmission Line Tower Foundation
    Xiang, Zhen
    Li, Xun
    Chen, Xiao
    Lv, Qishen
    Zhang, Chengwei
    Ai, Jingwen
    2019 4TH INTERNATIONAL CONFERENCE ON INTELLIGENT GREEN BUILDING AND SMART GRID (IGBSG 2019), 2019, : 82 - 86
  • [8] A Vertical Grounding Arrangement that Diminishes Impulse Coefficient in a Two-Layered Soil
    Batista, Raphael
    Caetano, Carlos E. F.
    Paulino, Jose O. S.
    Boaventura, Wallace C.
    2019 INTERNATIONAL SYMPOSIUM ON LIGHTNING PROTECTION (XV SIPDA), 2019,
  • [9] A Model for Simulation on grounding resistance of shore power
    Li Hongjiang
    Luo Ningzhao
    Xu Tao
    2012 INTERNATIONAL CONFERENCE ON CONTROL ENGINEERING AND COMMUNICATION TECHNOLOGY (ICCECT 2012), 2012, : 433 - 435
  • [10] An analytical thermal model for vertical ground heat exchangers in layered soil with thermal resistance
    Zhou, Xiangyun
    Hu, Shixiang
    Zhuo, Weiding
    Zhang, Xiayang
    Gao, You
    Sun, De'an
    Wen, Minjie
    COMPUTERS AND GEOTECHNICS, 2025, 179