Simultaneous profiling and quantification of 25 eicosanoids in human serum by ultrahigh-performance liquid chromatography coupled to tandem mass spectrometry

被引:6
|
作者
Lu, Yuanyuan [2 ]
Mai, Zhitong [4 ]
Zhou, Hongxia [3 ]
Guan, Wenda [1 ]
Wu, Shiguan [1 ]
Zou, Heyan [3 ]
Shen, Maoting [3 ]
Zhan, Yangqing [1 ]
Ye, Feng [1 ]
Qiu, Minshan [3 ]
Shen, Lihan [3 ]
Zhao, Beibei [2 ]
Yang, Zifeng [1 ,4 ,5 ,6 ]
机构
[1] Guangzhou Med Univ, Natl Clin Res Ctr Resp Dis, Guangzhou Inst Resp Hlth, State Key Lab Resp Dis,Affiliated Hosp 1, Guangzhou 510120, Guangdong, Peoples R China
[2] Guangzhou KingMed Ctr Clin Lab Co Ltd, Gaungzhou 510000, Guangdong, Peoples R China
[3] Southern Med Univ, Affiliated Dongguan Hosp, Dongguan Inst Resp & Crit Care Med, Dept Crit Care Med, Dongguan 523059, Guangdong, Peoples R China
[4] Macau Univ Sci & Technol, Macau Inst Appl Res Med & Hlth, State Key Lab Qual Res Chinese Med, Taipa, Macao, Peoples R China
[5] Guangzhou Lab, Guangzhou 510000, Peoples R China
[6] Guangzhou Key Lab Clin Rapid Diag & Early Warning, Guangzhou 510000, Guangdong, Peoples R China
关键词
Eicosanoids; LC-MS/MS; Bacteria; Severe pneumonia; INFECTION; LIPIDOMICS;
D O I
10.1007/s00216-022-04351-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The eicosanoid metabolic pathway is responsible for mediating the production of various inflammatory factors that are closely related to the development and resolution of inflammation. In biological matrices, the major quantifying obstacles were shown to be the oxidation and low quantities of eicosanoids and their metabolites. This study aimed to develop a reliable, sensitive ultrahigh-performance liquid chromatography coupled to a tandem mass spectrometry (UPLC-MS/MS) method to quantify eicosanoids in human serum. Solid-phase extraction (SPE) was used for sample preparation. The approach employed continuous ionization polarity switching. The target eicosanoids showed good linearity over the investigated concentration range (r2 > 0.99). The recovery rates were over 64.5%, and the matrix effects ranged from 73.0 to 128.0%. The limits of quantification were 0.048 similar to 0.44 ng/mL. For the broad concentration range, the CV % for accuracy and precision were less than +/- 20%. We successfully applied this method to rapidly analyse 74 serum samples from severe influenza pneumonia, severe bacterial pneumonia and healthy individuals. Eicosanoid-related metabolite concentrations were quantified within a range similar to those of previously published articles. Compared to healthy individuals, our application found that 20-HETE, 14,15-EET and 11,12-EET were upregulated in severe influenza pneumonia patients, while LTB4 was downregulated. 8-HETE and 5-HETE were upregulated in severe bacterial pneumonia patients, while LTE4 was downregulated. This approach provides a means for monitoring the low quantities of eicosanoids in biological matrices, and our finding that different characteristic metabolite profiles may help discriminate the induction of severe pneumonia patients .
引用
收藏
页码:8233 / 8244
页数:12
相关论文
共 50 条
  • [1] Simultaneous profiling and quantification of 25 eicosanoids in human serum by ultrahigh-performance liquid chromatography coupled to tandem mass spectrometry
    Yuanyuan Lu
    Zhitong Mai
    Hongxia Zhou
    Wenda Guan
    Shiguan Wu
    Heyan Zou
    Maoting Shen
    Yangqing Zhan
    Feng Ye
    Minshan Qiu
    Lihan Shen
    Beibei Zhao
    Zifeng Yang
    Analytical and Bioanalytical Chemistry, 2022, 414 : 8233 - 8244
  • [2] Analysis of oxylipins in human plasma: Comparison of ultrahigh-performance liquid chromatography and ultrahigh-performance supercritical fluid chromatography coupled to mass spectrometry
    Berkecz, Robert
    Lisa, Miroslav
    Holcapek, Michal
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1511 : 107 - 121
  • [3] High-Sensitivity and High-Throughput Quantification of Everolimus in Human Whole Blood Using Ultrahigh-Performance Liquid Chromatography Coupled With Tandem Mass Spectrometry
    Miyagi, Chika
    Tanaka, Ryota
    Hirata, Kenshiro
    Watanabe, Takuma
    Tatsuta, Ryosuke
    Miyamura, Shigeyuki
    Itoh, Hiroki
    THERAPEUTIC DRUG MONITORING, 2022, 44 (05) : 633 - 640
  • [4] Determination of 16 Mycotoxins in Maize by Ultrahigh-Performance Liquid Chromatography-Tandem Mass Spectrometry
    Li, Xia
    Liu, Bin
    Wang, Fengen
    Ma, Xinfeng
    Li, Zengmei
    Guo, Dongliang
    Wang, Yutao
    Wan, Fachun
    Deng, Ligang
    Zhang, Shuqiu
    ANALYTICAL LETTERS, 2018, 51 (05) : 702 - 716
  • [5] Determination of higenamine in common natural spices by ultrahigh-performance liquid chromatography-tandem mass spectrometry
    Du, Jinming
    Li, Xuefen
    Tian, Wenyi
    Guo, Chengjun
    DRUG TESTING AND ANALYSIS, 2024, 16 (12) : 1537 - 1543
  • [6] Felodipine quantification in human plasma by high-performance liquid chromatography coupled to tandem mass spectrometry
    Migliorança, LH
    Barrientos-Astigarraga, RE
    Schug, BS
    Blume, HH
    Pereira, AS
    De Nucci, G
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 814 (02): : 217 - 223
  • [7] Simultaneous Quantification of Seven Antifungal Agents in Human Serum Using Liquid Chromatography-Tandem Mass Spectrometry
    Li, Wenjing
    Li, Yang
    Cai, Junlong
    Wang, Yue
    Liu, Yanan
    Hu, Hankun
    Liu, Liang
    PHARMACEUTICALS, 2023, 16 (11)
  • [8] Simultaneous quantification of carbamate insecticides in human plasma by liquid chromatography/tandem mass spectrometry
    Mostafa, Ahmed
    Medley, Gregory
    Roberts, Darren M.
    Mohamed, Mosaad Sayed
    Elshanawani, Abdalla A.
    Roberts, Michael S.
    Liu, Xin
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (23): : 2234 - 2238
  • [9] Ultrahigh-performance liquid chromatography/tandem mass spectrometry method for evaluating enzyme activity and screening inhibitors of cyclooxygenase-2
    Zhu, Hongbin
    Zhuang, Xiaoyu
    Liu, Shu
    Pi, Zifeng
    Song, Fengrui
    Lin, Na
    Liu, Zhiqiang
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2014, 28 (16) : 1792 - 1800
  • [10] Simultaneous quantification of digoxin, digitoxin, and their metabolites in serum using high performance liquid chromatography-tandem mass spectrometry
    Bylda, Caroline
    Thiele, Roland
    Kobold, Uwe
    Volmer, Dietrich A.
    DRUG TESTING AND ANALYSIS, 2015, 7 (10) : 937 - 946