Clinical study of Widex Senso on first-time hearing aid users

被引:17
作者
Berninger, E [1 ]
Karlsson, KK [1 ]
机构
[1] Huddinge Univ Hosp, Dept Audiol, Karolinska Inst, S-14186 Huddinge, Sweden
来源
SCANDINAVIAN AUDIOLOGY | 1999年 / 28卷 / 02期
关键词
clinical study; digital signal processing; hearing aid; hearing loss;
D O I
10.1080/010503999424842
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Using psychoacoustic tests and questionnaires, the aim of this study was to clinically test Wider Sense (WS) versus analogue hearing aids on 200 first-time wearers. Half of the participants were selected at random for fitting with the behind-the-ear model (WS C8) or the in-the-canal model (WS CX). On a group basis, WS was found to provide more benefit than a palette of 29 analogue, modern hearing aid models from 10 manufacturers. Only 3 of 100 subjects changed from WS to another hearing aid. On average, the abbreviated profile of hearing aid benefit (APHAB) (Cox & Alexander, 1995) demonstrated superior performance for WS, i.e. no conflict existed between high comfort and high speech recognition. Median aided frequency-modulated tone thresholds in the sound field were better than 25 dB HL at frequencies up to 4 kHz inclusive. A distinct mean aided improvement of speech threshold in competing speech of 2.5 dB was found in both groups.
引用
收藏
页码:117 / 125
页数:9
相关论文
共 19 条
[1]  
[Anonymous], 1996, 3897 ISO
[2]   Clinical trial of a digital hearing aid [J].
Arlinger, S ;
Billermark, E ;
Oberg, M ;
Lunner, T ;
Hellgren, J .
SCANDINAVIAN AUDIOLOGY, 1998, 27 (01) :51-61
[3]   Report of the Eriksholm Workshop on Auditory Deprivation and Acclimatization [J].
Arlinger, S ;
Gatehouse, S ;
Bentler, RA ;
Byrne, D ;
Cox, RM ;
Dirks, DD ;
Humes, L ;
Neuman, A ;
Ponton, C ;
Robinson, K ;
Silman, S ;
Summerfield, AQ ;
Turner, CW ;
Tyler, RS .
EAR AND HEARING, 1996, 17 (03) :S87-S90
[4]  
Arlinger S., 1990, PRACTICAL ASPECTS AU, P70
[5]   RELIABILITY IN WARBLE-TONE SOUND FIELD AUDIOMETRY [J].
ARLINGER, SD ;
JERLVALL, LB .
SCANDINAVIAN AUDIOLOGY, 1987, 16 (01) :21-27
[6]   COUPLER-RELATED REAL EAR GAIN - INTERACTION BETWEEN SUBJECT AND HEARING-AID TYPE [J].
BERNINGER, E ;
OVEGARD, A ;
SVARD, I .
SCANDINAVIAN AUDIOLOGY, 1992, 21 (01) :15-22
[7]  
BULOW M, 1996, FIELD TEST EVALUATIO, P7
[8]   THE ABBREVIATED PROFILE OF HEARING-AID BENEFIT [J].
COX, RM ;
ALEXANDER, GC .
EAR AND HEARING, 1995, 16 (02) :176-186
[9]  
COX RM, 1996, PHONAK FOCUS, P21
[10]   ACOUSTIC FEEDBACK MARGIN IMPROVEMENTS IN HEARING INSTRUMENTS USING A PROTOTYPE DFS (DIGITAL FEEDBACK SUPPRESSION) SYSTEM [J].
DYRLUND, O ;
BISGAARD, N .
SCANDINAVIAN AUDIOLOGY, 1991, 20 (01) :49-53