Diagnostic Accuracy of Hepatic Vein Arrival Time Performed with Contrast-Enhanced Ultrasonography for Cirrhosis: A Systematic Review and Meta-Analysis

被引:26
作者
Kim, Gaeun [1 ]
Shim, Kwang Yong [2 ]
Baik, Soon Koo [2 ]
机构
[1] Keimyung Univ, Coll Nursing, Dept Nursing, Daegu, South Korea
[2] Yonsei Univ, Wonju Coll Med, Dept Internal Med, Wonju Severance Christian Hosp, Wonju, South Korea
关键词
Contrast-enhanced ultrasonography; Hepatic fibrosis; Meta-analysis; Systematic review; TRANSIT-TIME; PORTAL-HYPERTENSION; NONINVASIVE DIAGNOSIS; ULTRASOUND; SEVERITY; CURVE; FIBROSIS; DISEASE; PREDICT; BIAS;
D O I
10.5009/gnl16031
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background/Aims: We identified reports in the literature regarding the diagnostic accuracy of hepatic vein arrival time (HVAT) measured by contrast-enhanced ultrasonography (CEUS) to assess hepatic fibrosis in cirrhosis. Methods: The Ovid MEDLINE, Embase, and Cochrane databases were searched for all studies published up to 23 July 2015 that evaluated liver status using CEUS and liver biopsy (LB). The QUADAS-II (quality assessment of diagnostic accuracy studies-II) was applied to assess the internal validity of the diagnostic studies. Selected studies were subjected to a meta-analysis with MetaDisc 1.4 and RevMan 5.3. Results: A total of 12 studies including 844 patients with chronic liver disease met our inclusion criteria. The overall summary sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio of the HVAT measured by CEUS for the detection of cirrhosis compared to LB were 0.83 (95% confidence interval [CI], 0.77to 0.89), 0.75 (95% CI, 0.69 to 0.79), 3.45 (95% CI, 1.60 to 7.43), and 0.28 (95% CI, 0.10 to 0.74), respectively. The summary diagnostic odds ratio (random effects model) was 15.23 (95% CI, 3.07 to 75.47), the summary receiver operator characteristics area under the curve was 0.74 (standard error [SE]=0.14), and the index Q was 0.69 (SE=0.11). Conclusions: Based on a systematic review, the measurement of HVAT by CEUS exhibited an increased accuracy and correlation for the detection of cirrhosis.
引用
收藏
页码:93 / 101
页数:9
相关论文
共 36 条
[1]   Diagnosis of liver cirrhosis by transit-time analysis at contrast-enhanced ultrasonography [J].
Abbattista, T. ;
Ridolfi, F. ;
Ciabattoni, E. ;
Marini, F. ;
Bendia, E. ;
Brunelli, E. ;
Busilacchi, P. .
RADIOLOGIA MEDICA, 2008, 113 (06) :860-874
[2]   Non-invasive diagnosis of hepatic cirrhosis by transit-time analysis of an ultrasound contrast agent [J].
Albrecht, T ;
Blomley, MJK ;
Cosgrove, DO ;
Taylor-Robinson, SD ;
Jayaram, V ;
Eckersley, R ;
Urbank, A ;
Butler-Barnes, J ;
Patel, N .
LANCET, 1999, 353 (9164) :1579-1583
[3]   Haemodynamic evaluation by Doppler ultrasonography in patients with portal hypertension: a review [J].
Baik, Soon Koo .
LIVER INTERNATIONAL, 2010, 30 (10) :1403-1413
[4]   Science, medicine, and the future - Microbubble contrast agents: a new era in ultrasound [J].
Blomley, MJK ;
Cooke, JC ;
Unger, EC ;
Monaghan, MJ ;
Cosgrove, DO .
BMJ-BRITISH MEDICAL JOURNAL, 2001, 322 (7296) :1222-1225
[5]   Liver microbubble transit time compared with histology and Child-Pugh score in diffuse liver disease: a cross sectional study [J].
Blomley, MJK ;
Lim, AKP ;
Harvey, CJ ;
Patel, N ;
Eckersley, RJ ;
Basilico, R ;
Heckemann, R ;
Urbank, A ;
Cosgrove, DO ;
Taylor-Robinson, SD .
GUT, 2003, 52 (08) :1188-1193
[6]   Accuracy and reliability of microbubble ultrasound measurements for the non-invasive assessment of hepatic fibrosis in chronic hepatitis C [J].
Cobbold, Jeremy F. L. ;
Patel, Dhupal ;
Fitzpatrick, Julie A. ;
Patel, Nayna ;
Crossey, Mary M. E. ;
AbdAlla, Mohamed Saad ;
Goldin, Robert D. ;
Vennart, William ;
Thomas, Howard C. ;
Taylor-Robinson, Simon D. .
HEPATOLOGY RESEARCH, 2012, 42 (05) :515-522
[7]   The performance of tests of publication bias and other sample size effects in systematic reviews of diagnostic test accuracy was assessed [J].
Deeks, JJ ;
Macaskill, P ;
Irwig, L .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 2005, 58 (09) :882-893
[8]   Mesenchymal stem cell therapy for liver fibrosis [J].
Eom, Young Woo ;
Shim, Kwang Yong ;
Baik, Soon Koo .
KOREAN JOURNAL OF INTERNAL MEDICINE, 2015, 30 (05) :580-589
[9]   Noninvasive diagnosis of compensated cirrhosis using an analysis of the time-intensity curve portal vein slope gradient on contrast-enhanced ultrasonography [J].
Goto, Yuichi ;
Okuda, Koji ;
Akasu, Gen ;
Kinoshita, Hisafumi ;
Tanaka, Hiroyuki .
SURGERY TODAY, 2014, 44 (08) :1496-1505
[10]   Principles and practical application of the receiver-operating characteristic analysis for diagnostic tests [J].
Greiner, M ;
Pfeiffer, D ;
Smith, RD .