Taurolidine Lock Solutions for the Prevention of Catheter-Related Bloodstream Infections: A Systematic Review and Meta-Analysis of Randomized Controlled Trials

被引:105
作者
Liu, Yong [1 ]
Zhang, An-Qiang [2 ]
Cao, Lin [1 ]
Xia, Hong-Tao [1 ]
Ma, Jun-Jie [1 ]
机构
[1] Suining Cent Hosp, Intens Care Unit, Suining, Sichuan, Peoples R China
[2] Third Mil Med Univ, Daping Hosp, Inst Surg Res, State Key Lab Trauma Burns & Combined Injury, Chongqing, Peoples R China
关键词
HOME PARENTERAL-NUTRITION; CENTRAL VENOUS CATHETERS; TARGETED USE; HEMODIALYSIS; BACTEREMIA; CITRATE; HEPARIN; SEPSIS; CANCER; TAUROLOCK(R);
D O I
10.1371/journal.pone.0079417
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: Catheter-related bloodstream infections (CRBSIs) are a significant cause of morbidity and mortality in critically ill patients, contributing to prolonged hospital stays and increased costs. Whether taurolidine lock solutions (TLS) are beneficial for the prevention of CRBSIs remains controversial. In this meta-analysis, we aim to assess the efficacy of TLS for preventing CRBSIs. Methods: We conducted a systematic search of PubMed, EMBASE, and the Cochrane Central Register of Controlled Trials. Eligible studies included randomized controlled trials that reported on the effects of TLS for preventing CRBSIs. The primary outcome in these studies was catheter-related bloodstream infections, with microbial distribution of CRBSI and catheter-associated thrombosis as secondary outcomes. Data were combined using random-effects models owing to significant clinical heterogeneity. Results: Six randomized controlled trials (RCTs) conducted from 2004 through 2013 involving 431 patients and 86,078 catheter-days were included in the review. TLS were significantly associated with a lower incidence of CRBSIs when compared to heparin lock solutions (Risk Ratio [RR], 0.34; 95% Confidence Interval [CI], 0.21-0.55). Use of TLS significantly decreased the incidence of CRBSIs from gram-negative (G-) bacteria (P = 0.004; RR, 0.27; CI, 0.11-0.65), and was associated with a non-significant decrease in gram-positive (G+) bacterial infections (P = 0.07; RR, 0.41; CI, 0.15-1.09). No significant association was observed with TLS and catheter-associated thrombosis (RR, 1.99; CI, 0.75-5.28). Conclusions: The use of TLS reduced the incidence of CRBSIs without obvious adverse effects or bacterial resistance. However, the susceptibility of G+ and G- bacteria to taurolidine and the risk for catheter-associated thrombosis of TLS are indeterminate due to limited data. The results should be treated with caution due to the limited sample sizes and methodological deficiencies of included studies. Therefore, additional well-designed and adequately powered RCTs are needed to confirm these findings.
引用
收藏
页数:8
相关论文
共 53 条
[1]  
Akyüz C, 2010, PEDIATR BLOOD CANCER, V55, P949
[2]  
Al-Amin A, 2012, BRIT J SURG, V99, P158
[4]  
[Anonymous], HAREFUAH
[5]  
[Anonymous], J PEDIAT GASTROENTER
[6]  
[Anonymous], CLIN NUTR
[7]  
[Anonymous], CLIN NUTR S7
[8]  
[Anonymous], CURRENT ANAESTHESIA
[9]  
[Anonymous], J CLIN ONCOL
[10]  
[Anonymous], PEDIAT BLOOD CANC