Determination of trace cobalt(II) by adsorptive stripping voltammetry on disposable microfabricated electrochemical cells with integrated planar metal-film electrodes

被引:36
作者
Kokkinos, Christos [1 ]
Economou, Anastasios [1 ]
Koupparis, Michael [1 ]
机构
[1] Univ Athens, Dept Chem, Analyt Chem Lab, Athens 15771, Greece
关键词
Cobalt(II); Adsorptive stripping voltammetry; Bismuth-film electrode; Disposable sensors; Sputtered electrodes; Integrated electrodes; Microfabrication; CAPILLARY-ELECTROPHORESIS; CARBON ELECTRODES; BISMUTH; NICKEL(II); SENSORS;
D O I
10.1016/j.talanta.2008.08.009
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work reports the determination of trace Co(II) by adsorptive stripping voltammetry on disposable three-electrode cells with on-chip metal-film electrodes. The heart of the sensors was a bismuth-film electrode (BiFE) with Ag and Pt planar Strips Serving as the reference and counter electrodes respectively., Metals were deposited on a silicon chip by sputtering while the areas of the electrodes were patterned via a metal mask. Co(II) was determined by square wave adsorptive Stripping voltammetry (SWAdSV) after complexation with dimethylglyoxime (DMG). The experimental variables (the DMG concentration, the preconcentration potential, the accumulation time and the SW parameters), as well as potential interferences, were investigated. Using the selected conditions, the 3 sigma limit of detection was 0.09 mu g l(-1) of Co(II) (for 90 s of preconcentration) and the relative standard deviation for Co(II) was 3.8% at the 2 mu g l(-1) level (n = 8). The method was applied to the determination of Co(II) in a certified river water sample. These mercury-free electrochemical devices present increased scope for held analysis and mu-TAS applications. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1137 / 1142
页数:6
相关论文
共 32 条
[1]   Fully integrated on-chip electrochemical detection for capillary electrophoresis in a microfabricated device [J].
Baldwin, RP ;
Roussel, TJ ;
Crain, MM ;
Bathlagunda, V ;
Jackson, DJ ;
Gullapalli, J ;
Conklin, JA ;
Pai, R ;
Naber, JF ;
Walsh, KM ;
Keynton, RS .
ANALYTICAL CHEMISTRY, 2002, 74 (15) :3690-3697
[2]   Pulsed amperometric detection of sulfide, cyanide, iodide, thiosulfate, bromide and thiocyanate with microfabricated disposable silver working electrodes in ion chromatography [J].
Cheng, J ;
Jandik, P ;
Avdalovic, N .
ANALYTICA CHIMICA ACTA, 2005, 536 (1-2) :267-274
[3]   Bismuth-film electrodes: recent developments and potentialities for electroanalysis [J].
Economou, A .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (04) :334-340
[4]   A "virtual" electroanalytical instrument for square wave voltammetry [J].
Economou, A ;
Bolis, SD ;
Efstathiou, CE ;
Volikakis, GJ .
ANALYTICA CHIMICA ACTA, 2002, 467 (1-2) :179-188
[5]   Antimony film electrode for electrochemical stripping analysis [J].
Hocevar, Samo B. ;
Svancara, Ivan ;
Ogorevc, Bozidar ;
Vytras, Karel .
ANALYTICAL CHEMISTRY, 2007, 79 (22) :8639-8643
[6]   Ex situ preparation of bismuth film microelectrode for use in electrochemical stripping microanalysis [J].
Hutton, EA ;
Hocevar, SB ;
Ogorevc, M .
ANALYTICA CHIMICA ACTA, 2005, 537 (1-2) :285-292
[7]   Bismuth film electrode for simultaneous adsorptive stripping analysis of trace cobalt and nickel using constant current chronopotentiometric and voltammetric protocol [J].
Hutton, EA ;
Hocevar, SB ;
Ogorevc, B ;
Smyth, MR .
ELECTROCHEMISTRY COMMUNICATIONS, 2003, 5 (09) :765-769
[8]   A study of Nafion-coated bismuth-film electrodes for the determination of trace metals by anodic stripping voltammetry [J].
Kefala, G ;
Economou, A ;
Voulgaropoulos, A .
ANALYST, 2004, 129 (11) :1082-1090
[9]  
*KEMI, 2004, 404 KEMI
[10]   Structure and electrical transport properties of bismuth thin films prepared by RF magnetron sputtering [J].
Kim, DH ;
Lee, SH ;
Kim, JK ;
Lee, GH .
APPLIED SURFACE SCIENCE, 2006, 252 (10) :3525-3531