Measurement of single breath-hold carbon monoxide diffusing capacity in healthy infants and toddlers

被引:18
作者
Castillo, Andres [1 ]
Llapur, Conrado J. [1 ]
Martinez, Tanya [1 ]
Kisling, Jeff [1 ]
Williams-Nkomo, Tamica [1 ]
Coates, Cathy [1 ]
Tepper, Robert S. [1 ]
机构
[1] Indiana Univ, James Whitcomb Riley Hosp Children, Med Ctr, Dept Pediat, Indianapolis, IN 46202 USA
关键词
diffusing capacity; alveolar volume; lung growth;
D O I
10.1002/ppul.20403
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
We describe a method for measuring carbon monoxide diffusing capacity (DLCO) and alveolar volume (V-A) in sleeping infants, using a single 4-sec breath-hold technique. The breath-hold maneuver is obtained by inducing a respiratory pause of the respiratory system. Several inflations of the respiratory system with room air to a lung volume with an airway pressure of 30 cmH(2)O (V-30) inhibit inspiratory effort. The respiratory system is then inflated with a test gas containing helium and a stable isotope of carbon monoxide ((CO)-O-18), and a respiratory pause is maintained for 4 sec and followed by passive expiration to functional residual capacity. Concentrations of helium and (CO)-O-18 are continuously measured with a mass spectrometer. Twelve healthy infants between 6-22 months of age were evaluated. For 9 of 12 subjects, duplicate measurements of alveolar volume at 30 cmH(2)O (V-A30) and DLCO were within 10%, which are the recommendations for older children and adults. Among these 9 subjects, values of VA30 and DLCO increased with increasing body length (r(2) = 0.82 and 0.79, respectively). The remaining 3 subjects had two values within 10-15%. Measurement of V-A and DLCO with the single breath-hold technique at an elevated lung volume offers the potential to assess growth and development of the lung parenchyma early in life.
引用
收藏
页码:544 / 550
页数:7
相关论文
共 30 条
  • [1] AYERS LN, 1975, W J MED, V123, P264
  • [2] MEASUREMENT OF CARDIOPULMONARY FUNCTION IN VENTILATED NEONATES WITH RESPIRATORY-DISTRESS SYNDROME USING REBREATHING METHODOLOGY
    BOSE, CL
    LAWSON, EE
    GREENE, A
    MENTZ, W
    FRIEDMAN, M
    [J]. PEDIATRIC RESEARCH, 1986, 20 (04) : 316 - 320
  • [3] Determination of diffusing capacity by modeling the dynamics of C18O uptake in newborns
    Bouferrache, B
    Krim, G
    Mejdoub, N
    Quanjer, PH
    Freville, M
    Libert, JP
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1998, 45 (11) : 1305 - 1312
  • [4] BOULE M, 1986, B EUR PHYSIOPATH RES, V22, P467
  • [5] Castile R, 2000, PEDIATR PULM, V30, P215, DOI 10.1002/1099-0496(200009)30:3<215::AID-PPUL6>3.0.CO
  • [6] 2-V
  • [7] CASTILLO A, 2005, P AM THOR SOC, V2, pA185
  • [8] LUNG-VOLUMES, VENTILATORY CAPACITY, AND TRANSFER-FACTOR IN HEALTHY BRITISH BOY AND GIRL TWINS
    COTES, JE
    DABBS, JM
    HALL, AM
    AXFORD, AT
    LAURENCE, KM
    [J]. THORAX, 1973, 28 (06) : 709 - 715
  • [9] DUNNILL M. S., 1962, THORAX, V17, P329, DOI 10.1136/thx.17.4.329
  • [10] Flow limitation in normal infants: A new method for forced expiratory maneuvers from raised lung volumes
    Feher, A
    Castile, R
    Kisling, J
    Angelicchio, C
    Filbrun, D
    Flucke, R
    Tepper, R
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1996, 80 (06) : 2019 - 2025