Corneal Epithelial Thickness Intrasubject Repeatability and its Relation With Visual Limitation in Keratoconus

被引:41
作者
Vega-Estrada, Alfredo [1 ,2 ,3 ]
Mimouni, Michael [4 ,5 ]
Espla, Elias [1 ]
Alto del Barrio, Jorge [1 ,2 ,3 ]
Alio, Jorge L. [1 ,2 ,3 ]
机构
[1] Vissum, Dept Cornea & Refract Surg, Alicante, Spain
[2] Vissum, Keratoconus Unit, Alicante, Spain
[3] Univ Miguel Hernandez, Div Ophthalmol, Alicante, Spain
[4] Rambam Hlth Care Campus, Dept Ophthalmol, Haifa, Israel
[5] Technion Israel Inst Technol, Ruth & Bruce Rappaport Fac Med, Haifa, Israel
关键词
OPTICAL COHERENCE TOMOGRAPHY; ABERRATIONS; EYES;
D O I
10.1016/j.ajo.2019.01.015
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate intra-subject repeatability of anterior segment optical coherence tomography (AS-OCT) combined with placido disc MS-39 (CSO, Firenze, Italy) and correlate epithelial thickness measurements and the degree of visual limitation in keratoconus patients. DESIGN: Reliability analysis and cross-sectional study. METHODS: Setting: Vissum, Alicante, Spain. Subjects: Total of 167 eyes, of which 107 were from keratoconus patients and 60 were healthy. Procedures: Three repeated consecutive epithelial thickness measurements were taken: central 3.0 mm and the nasal, temporal, superior, and inferior regions at 3.0-6.0 mm and 6.0-8.0 mm. Main Outcome Measures: Intrasubject repeatability of epithelial indices was assessed and correlated to the degree of best-corrected visual acuity (BCVA). RESULTS: The intraclass correlation coefficient was >= 0.90, indicating highly repeatable measurements for both keratoconus and healthy eyes. In multivariate analysis, epithelial indices associated with worse BCVA were as follows: thinner 3 mm central (P = .04), thicker 8 mm superior (P < .001), and thinner 8 mm inferior (P < .001). Thickness central 3 mm decreased as keratoconus grading increased (P = .002). The superior-inferior ratio at 8 mm significantly increased as keratoconus grading increased (P < .001). In multivariate analysis thinner 3 mm central (R-2 = 6.19%, P = .04), greater superior-inferior 8 mm ratio (R-2 = 8.37%, P = .004), greater superior-inferior 6mm ratio (R-2 = 2.67%, P = .02), and steeper K2 (R-2 = 21.51%, P < .001) were associated with keratoconus with a combined area under the curve of 0.92. CONCLUSION: High repeatability of epithelial thickness measurements may be achieved in both keratoconus and healthy eyes with the MS-39. There is a significant correlation between epithelial thickness measurements and BCVA. These measurements may be of additional value in discriminating between keratoconus and healthy eyes. (C) 2019 Elsevier Inc. All rights reserved.
引用
收藏
页码:255 / 262
页数:8
相关论文
共 25 条
  • [21] Repeatability of automatic measurements by a new anterior segment optical coherence tomographer combined with Placido topography and agreement with 2 Scheimpflug cameras
    Savini, Giacomo
    Schiano-Lomoriello, Domenico
    Hoffer, Kenneth J.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (04) : 471 - 478
  • [22] HISTOPATHOLOGICAL VARIATION IN KERATOCONUS
    SCROGGS, MW
    PROIA, AD
    [J]. CORNEA, 1992, 11 (06) : 553 - 559
  • [23] Tang M., 2016, INVEST OPHTH VIS SCI, V57
  • [24] Corneal epithelial thickness mapping using Fourier-domain optical coherence tomography for detection of form fruste keratoconus
    Temstet, Cyril
    Sandali, Otman
    Bouheraoua, Nacim
    Hamiche, Taous
    Galan, Alice
    El Sanharawi, Mohamed
    Bashi, Elena
    Laroche, Laurent
    Borderie, Vincent
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (04) : 812 - 820
  • [25] Outcome Analysis of Intracorneal Ring Segments for the Treatment of Keratoconus Based on Visual, Refractive, and Aberrometric Impairment
    Vega-Estrada, Alfredo
    Alio, Jorge L.
    Brenner, Luis F.
    Javaloy, Jaime
    Plaza Puche, Ana Belen
    Barraquer, Rafael I.
    Teus, Miguel A.
    Murta, Joaquim
    Henriques, Jorge
    Uceda-Montanes, Antonio
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2013, 155 (03) : 575 - 584