Corneal Epithelial Thickness Intrasubject Repeatability and its Relation With Visual Limitation in Keratoconus

被引:41
作者
Vega-Estrada, Alfredo [1 ,2 ,3 ]
Mimouni, Michael [4 ,5 ]
Espla, Elias [1 ]
Alto del Barrio, Jorge [1 ,2 ,3 ]
Alio, Jorge L. [1 ,2 ,3 ]
机构
[1] Vissum, Dept Cornea & Refract Surg, Alicante, Spain
[2] Vissum, Keratoconus Unit, Alicante, Spain
[3] Univ Miguel Hernandez, Div Ophthalmol, Alicante, Spain
[4] Rambam Hlth Care Campus, Dept Ophthalmol, Haifa, Israel
[5] Technion Israel Inst Technol, Ruth & Bruce Rappaport Fac Med, Haifa, Israel
关键词
OPTICAL COHERENCE TOMOGRAPHY; ABERRATIONS; EYES;
D O I
10.1016/j.ajo.2019.01.015
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate intra-subject repeatability of anterior segment optical coherence tomography (AS-OCT) combined with placido disc MS-39 (CSO, Firenze, Italy) and correlate epithelial thickness measurements and the degree of visual limitation in keratoconus patients. DESIGN: Reliability analysis and cross-sectional study. METHODS: Setting: Vissum, Alicante, Spain. Subjects: Total of 167 eyes, of which 107 were from keratoconus patients and 60 were healthy. Procedures: Three repeated consecutive epithelial thickness measurements were taken: central 3.0 mm and the nasal, temporal, superior, and inferior regions at 3.0-6.0 mm and 6.0-8.0 mm. Main Outcome Measures: Intrasubject repeatability of epithelial indices was assessed and correlated to the degree of best-corrected visual acuity (BCVA). RESULTS: The intraclass correlation coefficient was >= 0.90, indicating highly repeatable measurements for both keratoconus and healthy eyes. In multivariate analysis, epithelial indices associated with worse BCVA were as follows: thinner 3 mm central (P = .04), thicker 8 mm superior (P < .001), and thinner 8 mm inferior (P < .001). Thickness central 3 mm decreased as keratoconus grading increased (P = .002). The superior-inferior ratio at 8 mm significantly increased as keratoconus grading increased (P < .001). In multivariate analysis thinner 3 mm central (R-2 = 6.19%, P = .04), greater superior-inferior 8 mm ratio (R-2 = 8.37%, P = .004), greater superior-inferior 6mm ratio (R-2 = 2.67%, P = .02), and steeper K2 (R-2 = 21.51%, P < .001) were associated with keratoconus with a combined area under the curve of 0.92. CONCLUSION: High repeatability of epithelial thickness measurements may be achieved in both keratoconus and healthy eyes with the MS-39. There is a significant correlation between epithelial thickness measurements and BCVA. These measurements may be of additional value in discriminating between keratoconus and healthy eyes. (C) 2019 Elsevier Inc. All rights reserved.
引用
收藏
页码:255 / 262
页数:8
相关论文
共 25 条
  • [1] Alió JL, 2006, J REFRACT SURG, V22, P539
  • [2] Keratoconus-integrated characterization considering anterior corneal aberrations, internal astigmatism, and corneal biomechanics
    Alio, Jorge L.
    Pinero, David P.
    Aleson, Alicia
    Teus, Miguel A.
    Barraquer, Rafael I.
    Murta, Joaquim
    Maldonado, Miguel J.
    Castro de Luna, Gracia
    Gutierrez, Ramon
    Villa, Cesar
    Uceda-Montanes, Antonio
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (03) : 552 - 568
  • [3] *KERATOCONE CLASSIQUE ET KERATOCONE FRUSTE - ARGUMENTS UNITAIRES
    AMSLER, M
    [J]. OPHTHALMOLOGICA, 1946, 111 (2-3) : 96 - 101
  • [4] Keratoconus: The ABCD Grading System
    Belin, M. W.
    Duncan, J. K.
    [J]. KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2016, 233 (06) : 701 - 707
  • [5] Bland JM, 1996, BRIT MED J, V313, P744
  • [6] Clinical grading of post-LASIK ectasia related to visual limitation and predictive factors for vision loss
    Brenner, Luis F.
    Alio, Jorge L.
    Vega-Estrada, Alfredo
    Baviera, Julio
    Beltran, Jaime
    Cobo-Soriano, Rosario
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (10) : 1817 - 1826
  • [7] Advanced anterior segment imaging in keratoconus: a review
    Gokul, Akilesh
    Vellara, Hans R.
    Patel, Dipika V.
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2018, 46 (02) : 122 - 132
  • [8] A 48-YEAR CLINICAL AND EPIDEMIOLOGIC-STUDY OF KERATOCONUS
    KENNEDY, RH
    BOURNE, WM
    DYER, JA
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 1986, 101 (03) : 267 - 273
  • [9] Subclinical keratoconus detection by pattern analysis of corneal and epithelial thickness maps with optical coherence tomography
    Li, Yan
    Chamberlain, Winston
    Tan, Ou
    Brass, Robert
    Weiss, Jack L.
    Huang, David
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (02) : 284 - 295
  • [10] Corneal Epithelial Thickness Mapping by Fourier-Domain Optical Coherence Tomography in Normal and Keratoconic Eyes
    Li, Yan
    Tan, Ou
    Brass, Robert
    Weiss, Jack L.
    Huang, David
    [J]. OPHTHALMOLOGY, 2012, 119 (12) : 2425 - 2433