THE IMPACT OF WORKFLOW AND VOLUMETRIC FEEDBACK ON FRAMELESS IMAGE-GUIDED NEUROSURGERY

被引:10
作者
Woerdeman, Peter A. [1 ]
Willems, Peter W. A. [1 ]
Noordmans, Herke J. [2 ]
Tulleken, Cornelis A. F. [1 ]
Van der Sprenkel, Jan W. B. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Neurosurg, Rudolf Magnus Inst Neurosci, NL-3584 CX Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Dept Med Technol & Clin Phys, NL-3584 CX Utrecht, Netherlands
关键词
Brain shift; Instrument tracking; Interface; Neuronavigation; Tumor resection; INTRAOPERATIVE 3D ULTRASOUND; BRAIN-TUMOR RESECTION; FUNCTIONAL NEURONAVIGATION; INITIAL-EXPERIENCE; MRI; SURGERY; GLIOMAS; VISUALIZATION; LOCALIZATION; TRACTOGRAPHY;
D O I
10.1227/01.NEU.0000335791.85615.38
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: During image-guided neurosurgery, if the surgeon is not fully orientated to the surgical position, he or she will briefly shift attention toward the visualization interface of an image guidance station, receiving only momentary "point-in-space" information. The aim of this study was to develop a novel visual interface for neuronavigation during brain tumor surgery, enabling intraoperative feedback on the entire progress of surgery relative to the anatomy of the brain and its pathology, regardless of the interval at which the surgeon chooses to look. METHODS: New software written in Java (Sun Microsystems, Inc., Santa Clara, CA) was developed to visualize the Cumulative recorded instrument positions intraoperatively. This allowed surgeons to see all previous instrument positions during the elapsed surgery. This new interactive interface was then used in 17 frameless image-guided neurosurgical procedures. The purpose of the first 11 cases was to obtain clinical experience with this new interface. In these cases, workflow and volumetric feedback (WVF) were available at the surgeons' discretion (Protocol A). In the next 6 cases, WVF was provided only after a complete resection was claimed (Protocol B). RESULTS: With the novel interactive interface, dynamics of surgical resection, displacement of cortical anatomy, and digitized functional data could be visualized intraoperatively. In the first group (Protocol A), surgeons expressed the view that WVF had affected their decision making and aided resection 0 0 of I I cases). In 3 of 6 cases in the second group (Protocol B), tumor resections were extended after evaluation of WVF By digitizing the cortical surface, an impression of the cortical shift could be acquired in all 17 cases. The maximal cortical shift measured 20 mm, but it typically varied between 0 and 10 mm. CONCLUSION: Our first clinical results suggest that the embedding of WVF contributes to improvement of surgical awareness and tumor resection in image-guided neurosurgery in a swift and simple manner.
引用
收藏
页码:S170 / S176
页数:7
相关论文
共 50 条
  • [31] An Automatic Spatial Registration Method for Image-Guided Neurosurgery System
    Fan, Yifeng
    Yao, Xufeng
    Hu, Tingting
    Xu, Xiufang
    JOURNAL OF CRANIOFACIAL SURGERY, 2019, 30 (04) : E344 - E350
  • [32] A Method for Planning Safe Trajectories in Image-Guided Keyhole Neurosurgery
    Shamir, Reuben R.
    Tamir, Idit
    Dabool, Elad
    Joskowicz, Leo
    Shoshan, Yigal
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2010, PT III, 2010, 6363 : 457 - +
  • [33] Image-guided frameless stereotactic biopsy sampling of parasellar lesions - Technical note
    Frighetto, L
    De Salles, AAE
    Behnke, E
    Smith, ZA
    Chute, D
    JOURNAL OF NEUROSURGERY, 2003, 98 (04) : 920 - 925
  • [34] Optimizing nonrigid registration performance between volumetric true 3D ultrasound images in image-guided neurosurgery
    Ji, Songbai
    Fan, Xiaoyao
    Roberts, David W.
    Hartov, Alex
    Paulsen, Keith D.
    MEDICAL IMAGING 2011: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2011, 7964
  • [35] TECHNIQUE FOR TARGETING ARTERIOVENOUS MALFORMATIONS USING FRAMELESS IMAGE-GUIDED ROBOTIC RADIOSURGERY
    Hristov, Dimitre
    Liu, Lina
    Adler, John R.
    Gibbs, Iris C.
    Moore, Teri
    Sarmiento, Marily
    Chang, Steve D.
    Dodd, Robert
    Marks, Michael
    Do, Huy M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 79 (04): : 1232 - 1240
  • [36] ! Accuracy of frameless image-guided implantation of depth electrodes for intracranial epilepsy monitoring
    Gross, Robert E.
    Sung, Edward K.
    Mulligan, Patrick
    Laxpati, Nealen G.
    Mayo, Darlene A.
    Rolston, John D.
    JOURNAL OF NEUROSURGERY, 2020, 132 (03) : 681 - 691
  • [37] Segmentation-based registration of ultrasound volumes for glioma resection in image-guided neurosurgery
    Canalini, Luca
    Klein, Jan
    Miller, Dorothea
    Kikinis, Ron
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2019, 14 (10) : 1697 - 1713
  • [38] Implications of Extracranial Distortion in Ultra-High-Field Magnetic Resonance Imaging for Image-Guided Cranial Neurosurgery
    Voormolen, Eduard H.
    Diederen, Sander J. H.
    Woerdeman, Peter
    van der Sprenkel, Jan Willem Berkelbach
    Noordmans, Herke Jan
    Visser, Fredy
    Viergever, Max A.
    Luijten, Peter
    Hoogduin, Hans
    Robe, Pierre A.
    WORLD NEUROSURGERY, 2019, 126 : E250 - E258
  • [39] Brain shift estimation in image-guided neurosurgery using 3-D ultrasound
    Letteboer, MMJ
    Willems, PWA
    Viergever, MA
    Niessen, WJ
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (02) : 268 - 276
  • [40] Automatic and efficient MRI-US segmentations for improving intraoperative image fusion in image-guided neurosurgery
    Nitsch, J.
    Klein, J.
    Dammann, P.
    Wrede, K.
    Gembruch, O.
    Moltz, J. H.
    Meine, H.
    Sure, U.
    Kikinis, R.
    Miller, D.
    NEUROIMAGE-CLINICAL, 2019, 22