Direct cone-beam cardiac reconstruction algorithm with cardiac banding artifact correction

被引:28
作者
Taguchi, K [1 ]
Chiang, BS [1 ]
Hein, IA [1 ]
机构
[1] Bioimaging Res Inc, Lincolnshire, IL 60069 USA
关键词
computed tomography; cardiac; temporal resolution; artifact;
D O I
10.1118/1.2163247
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Multislice helical computed tomography (CT) is a promising noninvasive technique for coronary artery imaging. Various factors can cause inconsistencies in cardiac CT data, which can result in degraded image quality. These inconsistencies may be the result of the patient physiology (e.g., heart rate variations), the nature of the data (e.g., cone-angle), or the reconstruction algorithm itself. An algorithm which provides the best temporal resolution for each slice, for example, often provides suboptimal image quality for the entire volume since the cardiac temporal resolution (TRc) changes from slice to slice. Such variations in TRc can generate strong banding artifacts in multiplanar reconstruction images or three-dimensional images. Discontinuous heart walls and coronary arteries may compromise the accuracy of the diagnosis. A beta-blocker is often used to reduce and stabilize patients' heart rate but cannot eliminate the variation. In order to obtain robust and optimal image quality, a software solution that increases the temporal resolution and decreases the effect of heart rate is highly desirable. This paper proposes an ECG-correlated direct cone-beam reconstruction algorithm (TCOT-EGR) with cardiac banding artifact correction (CBC) and disconnected projections redundancy compensation technique (DIRECT). First the theory and analytical model of the cardiac temporal resolution is outlined. Next, the performance of the proposed algorithms is evaluated by using computer simulations as well as patient data. It will be shown that the proposed algorithms enhance the robustness of the image quality against inconsistencies by guaranteeing smooth transition of heart cycles used in reconstruction. (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:521 / 539
页数:19
相关论文
共 40 条
[1]  
ANNO H, 2004, JPN SOC CRDIOVASCULA, V59
[2]  
ANNO H, 2003, MED REV MAR, P1
[3]  
ANNO H, 2003, SUPPLEMENT INNERVISI, V18, P4
[4]  
BOYD DP, 1981, RADIOLOGY SKULL BRAI, V5, P4357
[5]   High temporal resolution volume heart imaging with multirow computed tomography [J].
Bruder, H ;
Schaller, S ;
Ohnesorge, B ;
Mertelmeier, T .
MEDICAL IMAGING 1999: IMAGE PROCESSING, PTS 1 AND 2, 1999, 3661 :420-432
[6]   Exact fan-beam reconstruction via ramp-filtered backprojection and local compensation [J].
Chen, GH ;
Tolakanahalli, R ;
Zhuang, TL ;
Nett, BE ;
Hsieh, J .
Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 :1014-1024
[7]  
CHEN Y, 2004, IEEE MED IM C IEEE R
[8]   Multisegment and halfscan reconstruction of 16-slice computed tomography for detection of coronary artery stenoses [J].
Dewey, M ;
Laule, M ;
Krug, L ;
Schnapauff, D ;
Rogalla, P ;
Rutsch, WF ;
Hamm, B ;
Lembcke, A .
INVESTIGATIVE RADIOLOGY, 2004, 39 (04) :223-229
[9]   PRACTICAL CONE-BEAM ALGORITHM [J].
FELDKAMP, LA ;
DAVIS, LC ;
KRESS, JW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06) :612-619
[10]   Image reconstruction and performance evaluation for ECG-gated spiral scanning with a 16-slice CT system [J].
Flohr, T ;
Ohnesorge, B ;
Bruder, H ;
Stierstorfer, K ;
Simon, J ;
Suess, C ;
Schaller, S .
MEDICAL PHYSICS, 2003, 30 (10) :2650-2662