Reliability Assessment of Various Sonographic Techniques for Evaluating Carpal Tunnel Syndrome

被引:19
作者
Junck, Anthony D. [1 ]
Escobedo, Eva M. [1 ]
Lipa, Bethany M. [2 ]
Cronan, Michael [1 ]
Anthonisen, Colleen [2 ]
Poltavskiy, Eduard [3 ]
Bang, Heejung [3 ]
Han, Jay J. [2 ]
机构
[1] Univ Calif Davis, Sch Med, Dept Radiol, Sacramento, CA 95817 USA
[2] Univ Calif Davis, Sch Med, Dept Phys Med & Rehabil, Sacramento, CA 95817 USA
[3] Univ Calif Davis, Dept Publ Hlth Sci, Davis, CA 95616 USA
基金
美国国家卫生研究院;
关键词
carpal tunnel syndrome; cross-sectional area; median nerve; musculoskeletal ultrasound; reliability; sonography; MEDIAN NERVE; NERVE/TUNNEL INDEX; DIAGNOSIS; ULTRASONOGRAPHY; METAANALYSIS; PREVALENCE;
D O I
10.7863/ultra.15.01069
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives-The aim of this study was to determine the intra- and inter-rater reliability of sonographic measurements of the median nerve cross-sectional area in individuals with carpal tunnel syndrome and healthy control participants. Methods-The median nerve cross-sectional area was evaluated by sonography in 18 participants with carpal tunnel syndrome (18 upper extremities) and 9 control participants (18 upper extremities) at 2 visits 1 week apart. Two examiners, both blinded to the presence or absence of carpal tunnel syndrome, captured independent sonograms of the median nerve at the levels of the carpal tunnel inlet, pronator quadratus, and mid-forearm. The cross-sectional area was later measured by each examiner independently. Each also traced images that were captured by the other examiner. Results-Both the intra- and inter-rater reliability rates were highest for images taken at the carpal tunnel inlet (radiologist, r = 0.86; sonographer, r = 0.87; inter-rater, r = 0.95; all P < .0001), whereas they was lowest for the pronator quadratus (r = 0.49, 0.29, and 0.72, respectively; all P < .0001). At the mid-forearm, the intra-rater reliability was lower for both the radiologist and sonographer, whereas the inter-rater reliability was relatively high (r = 0.54, 0.55, and 0.81; all P < .0001). Tracing of captured images by different examiners showed high concordance for the median cross-sectional area at the carpal tunnel inlet (r = 0.96-0.98; P < .0001). Conclusions-The highest intra- and inter-rater reliability was found at the carpal tunnel inlet. The results also demonstrate that tracing of the median nerve cross-sectional area from captured images by different examiners does not contribute significantly to measurement variability.
引用
收藏
页码:2077 / 2088
页数:12
相关论文
共 26 条
[1]   Reproducibility of sonographic measurements of the median nerve [J].
Aleman, Luis ;
Berna, Juan D. ;
Reus, Manuel ;
Martinez, Francisco ;
Domenech-Ratto, Gines ;
Campos, Matilde .
JOURNAL OF ULTRASOUND IN MEDICINE, 2008, 27 (02) :193-197
[2]   Prevalence of carpal tunnel syndrome in a general population [J].
Atroshi, I ;
Gummesson, C ;
Johnssson, R ;
Ornstein, E ;
Ranstam, J ;
Rosén, I .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1999, 282 (02) :153-158
[3]   Sonography in the diagnosis of carpal tunnel syndrome: A critical review of the literature [J].
Beekman, R ;
Visser, LH .
MUSCLE & NERVE, 2003, 27 (01) :26-33
[4]   CARPAL-TUNNEL SYNDROME - PREVALENCE IN THE GENERAL-POPULATION [J].
DEKROM, MCTFM ;
KNIPSCHILD, PG ;
KESTER, ADM ;
THIJS, CT ;
BOEKKOOI, PF ;
SPAANS, F .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 1992, 45 (04) :373-376
[5]   Meta-Analysis on the Performance of Sonography for the Diagnosis of Carpal Tunnel Syndrome [J].
Descatha, Alexis ;
Huard, Laure ;
Aubert, Francois ;
Barbato, Bruno ;
Gorand, Olivier ;
Chastang, Jean-Francois .
SEMINARS IN ARTHRITIS AND RHEUMATISM, 2012, 41 (06) :914-922
[6]  
Evans KD, 2012, J ULTRAS MED, V31, P729
[7]   DYNAMIC SONOGRAPHIC MEASUREMENTS AT THE CARPAL TUNNEL INLET: RELIABILITY AND REFERENCE VALUES IN HEALTHY WRISTS [J].
Filius, Anika ;
Korstanje, Jan-Wiebe H. ;
Selles, Ruud W. ;
Hovius, Steven E. R. ;
Slijper, Harm P. .
MUSCLE & NERVE, 2013, 48 (04) :525-531
[8]   The ultrasonographic wrist-to-forearm median nerve area ratio in carpal tunnel syndrome [J].
Hobson-Webb, Lisa D. ;
Massey, Janice M. ;
Juel, Vern C. ;
Sanders, Donald B. .
CLINICAL NEUROPHYSIOLOGY, 2008, 119 (06) :1353-1357
[9]   SONOGRAPHY IN CARPAL TUNNEL SYNDROME [J].
Hunderfund, Andrea N. Leep ;
Boon, Andrea J. ;
Mandrekar, Jayawant N. ;
Sorenson, Eric J. .
MUSCLE & NERVE, 2011, 44 (04) :485-491
[10]   REPEATABILITY OF ULTRASONOGRAPHIC MEDIAN NERVE MEASURES [J].
Impink, Bradley G. ;
Gagnon, Dany ;
Collinger, Jennifer L. ;
Boninger, Michael L. .
MUSCLE & NERVE, 2010, 41 (06) :767-773