Electrochemical Dissolved Oxygen Sensor-Integrated Platform for Wireless In Situ Bioprocess Monitoring

被引:30
作者
Stine, Justin M. [1 ,2 ]
Beardslee, Luke A. [2 ]
Sathyam, Rajendra M. [1 ]
Bentley, William E. [3 ,4 ,5 ]
Ghodssi, Reza [1 ,2 ,4 ,5 ]
机构
[1] Univ Maryland, Dept Elect & Comp Engn, Kim Bldg 2236, College Pk, MD 20742 USA
[2] Univ Maryland, Inst Syst Res, College Pk, MD 20742 USA
[3] Univ Maryland, Inst Biosci & Biotechnol Res, College Pk, MD 20742 USA
[4] Univ Maryland, Robert E Fischell Inst Biomed Devices, College Pk, MD 20742 USA
[5] Univ Maryland, Fischell Dept Bioengn, College Pk, MD 20742 USA
基金
美国国家科学基金会;
关键词
Dissolved Oxygen; Bioreactor; Bluetooth Low Energy; Clark-type Sensor; Wireless Electronics; ANTIBODY; CAPSULE; COST;
D O I
10.1016/j.snb.2020.128381
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work presents a bio-processing online device (bPod) platform, capable of real-time in situ monitoring of bioreactor cell culture parameters, such as dissolved oxygen (DO). The bPod is an integrated system comprised of a potentiostat analog-front-end (AFE), a Bluetooth Low Energy (BLE) microcontroller, and a chemical sensor, exemplified here by a Clark-type DO sensor, which enables monitoring of dissolved oxygen content. The Clark-type electrochemical sensor performs chronoamperometric measurement of DO percent saturation, and the BLE microcontroller wirelessly transmits data to a smartphone while submerged in aqueous media. After several electrode design modifications, the bPod showed a linear electrochemical current response corresponding to DO percent saturation levels with a sensitivity of 37.5 nA/DO% and limit of detection of 8.26 DO%, covering concentration ranges relevant for mammalian culture processes within bioreactors. The wireless bPod provides a free-floating capsule architecture for monitoring DO and can be adapted for an array of electrochemical sensors, targeting different process parameters for diverse bioprocess monitoring applications.
引用
收藏
页数:9
相关论文
共 42 条
  • [21] Park J, 2007, IEEE SENSOR, P1412
  • [22] Potyrailo R. A., 2011, 2011 IEEE International Conference on RFID-Technologies and Applications (RFID-TA), P16, DOI 10.1109/RFID-TA.2011.6068609
  • [23] A passive radio-frequency identification (RFID) gas sensor with self-correction against fluctuations of ambient temperature
    Potyrailo, Radislav A.
    Surman, Cheryl
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2013, 185 : 587 - 593
  • [24] SmartINST, 2015, IN SIT WIR MEAS
  • [25] Techniques for oxygen transfer measurement in bioreactors: a review
    Suresh, S.
    Srivastava, V. C.
    Mishra, I. M.
    [J]. JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2009, 84 (08) : 1091 - 1103
  • [26] Surman C., 2011, 2011 IEEE International Conference on RFID (IEEE RFID 2011), P78, DOI 10.1109/RFID.2011.5764640
  • [27] Distribution and mass transfer of dissolved oxygen in a multi-habitat membrane bioreactor
    Tang, Bing
    Qiu, Bing
    Huang, Shaosong
    Yang, Kanghua
    Bin, Liying
    Fu, Fenglian
    Yang, Huiwen
    [J]. BIORESOURCE TECHNOLOGY, 2015, 182 : 323 - 328
  • [28] Influence of the Working and Counter Electrode Surface Area Ratios on the Dissolution of Platinum under Electrochemical Conditions
    Tian, Min
    Cousins, Christine
    Beauchemin, Diane
    Furuya, Yoshihisa
    Ohma, Atsushi
    Jerkiewicz, Gregory
    [J]. ACS CATALYSIS, 2016, 6 (08): : 5108 - 5116
  • [29] Autonomous Sensor Capsule for Usage in Bioreactors
    Todtenberg, Nicole
    Schmitz-Hertzberg, Sebastian-Tim
    Schmalz, Klaus
    Klatt, Joerg
    Jorde, Felix
    Juettner, Bjoern
    Kraemer, Rolf
    [J]. IEEE SENSORS JOURNAL, 2015, 15 (07) : 4093 - 4102
  • [30] Todtenberg N, 2013, EUR MICROW CONF, P712