Evaluation of an improved air distribution system for aircraft cabin

被引:29
作者
Pang, Liping [1 ,2 ]
Xu, Jie [1 ]
Fang, Lei [2 ]
Gong, Mengmeng [1 ]
Zhang, Hua [1 ]
Zhang, Yu [1 ]
机构
[1] Beijing Univ Aeronaut & Astronaut, Sch Aviat Sci & Engn, Beijing 100191, Peoples R China
[2] Tech Univ Denmark, Int Ctr Indoor Environm & Energy, DK-2800 Lyngby, Denmark
关键词
Civil aircraft cabin; Air distribution system; Air quality; Flow visualization; Personal exposure effectiveness; Energy consumption; FLOWS; CFD;
D O I
10.1016/j.buildenv.2012.08.015
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An improved air distribution system for aircraft cabin was proposed in this paper. Personalized outlets were introduced and placed at the bottom of the baggage hold. Its ratio of fresh air to recirculation air and the conditioned temperature of different types of inlets were also designed carefully to meet the goals of high air quality, thermal comfort and energy saving. Some experiments were conducted to evaluate and compare its performances with two other systems. First the Flow Visualization with Green Laser (FVGL) technology was used to analyze the air flow. The top-in-side bottom-out pattern may have the disadvantages of an indirect path to deliver fresh air to passengers, a low fresh air utilization ratio and the potential to widely spreading airborne infectious diseases. The bottom-in-top-out pattern can overcome these disadvantages very well, but it also faces the stratification of contaminated air above the head of the passengers. The improved pattern may overcome the above challenges quite well while also delivering good ventilation performance. The modified Personal Exposure Effectiveness (PEE) was measured to compare their performances with regard to inhaled air quality. The measured results suggest that personalized inlet should be designed to adjust its supply air angle according to the height of the passenger's face to provide a higher fresh air utilization effectiveness and better air quality for passengers in the improved pattern. Some simulations revealed that the improved pattern had the potential to save energy by decreasing the amount of fresh air without significantly affecting air quality and thermal comfort. (c) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:145 / 152
页数:8
相关论文
共 25 条
  • [1] Alkanchy H, 2008, P IND AIR 20O8 COP D
  • [2] Doron Bar-Shalom, 1989, ALTITUDE EFFECTS HEA, P15
  • [3] Experimental validation of local exhaust strategies for improved IAQ in aircraft cabins
    Dygert, Ryan K.
    Dang, Thong Q.
    [J]. BUILDING AND ENVIRONMENT, 2012, 47 : 76 - 88
  • [4] Mitigation of cross-contamination in an aircraft cabin via localized exhaust
    Dygert, Ryan K.
    Dang, Thong Q.
    [J]. BUILDING AND ENVIRONMENT, 2010, 45 (09) : 2015 - 2026
  • [5] Faleiro L, 2004, YOK JAP 24 C INT COU
  • [6] Personalized ventilation for commercial aircraft cabins
    Gao, N. P.
    Niu, J. L.
    [J]. JOURNAL OF AIRCRAFT, 2008, 45 (02): : 508 - 512
  • [7] Gao NP, 2008, ASHRAE TRAN, V114, P37
  • [8] CFD study on micro-environment around human body and personalized ventilation
    Gao, NP
    Niu, JL
    [J]. BUILDING AND ENVIRONMENT, 2004, 39 (07) : 795 - 805
  • [9] Howells I., 1976, AGARD C P
  • [10] Individual and collective climate control in aircraft cabins
    Jacobs, P.
    de Gids, W. F.
    [J]. INTERNATIONAL JOURNAL OF VEHICLE DESIGN, 2006, 42 (1-2) : 57 - 66