Incidence, Predictors, and Mid-Term Outcomes of Possible Leaflet Thrombosis After TAVR

被引:151
作者
Yanagisawa, Ryo [1 ]
Hayashida, Kentaro [1 ]
Yamada, Yoshitake [2 ]
Tanaka, Makoto [1 ]
Yashima, Fumiaki [1 ]
Inohara, Taku [1 ]
Arai, Takahide [1 ]
Kawakami, Takashi [1 ]
Maekawa, Yuichiro [1 ]
Tsuruta, Hikaru [1 ]
Itabashi, Yuji [1 ]
Murata, Mitsushige [1 ]
Sano, Motoaki [1 ]
Okamoto, Kazuma [3 ]
Yoshitake, Akihiro [3 ]
Shimizu, Hideyuki [3 ]
Jinzaki, Masahiro [2 ]
Fukuda, Keiichi [1 ]
机构
[1] Keio Univ, Sch Med, Dept Cardiol, Tokyo, Japan
[2] Keio Univ, Sch Med, Dept Diagnost Radiol, Tokyo, Japan
[3] Keio Univ, Sch Med, Dept Cardiovasc Surg, Tokyo, Japan
关键词
aortic stenosis; D-dimer; reduced leaflet motion; TAVR; thrombosis; AORTIC-VALVE-REPLACEMENT; HEART-VALVES; TRANSCATHETER; IMPLANTATION; PROSTHESIS; STENOSIS; SURGERY;
D O I
10.1016/j.jcmg.2016.11.005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study sought to clarify the incidence and predictors of hypoattenuated leaflet thickening (HALT) and mid-term outcomes after transcatheter aortic valve replacement. BACKGROUND HALT detected on multidetector computed tomography (MDCT) scanning raised concerns about possible subdinical leaflet thrombosis. METHODS We studied 70 of 100 consecutive patients from a single-center registry who underwent implantation with the Edwards SAPIEN-XT device. MDCT results, echocardiographic data, and laboratory findings obtained at the 6-month and 1-year follow-ups were analyzed. RESULTS Of 70 patients, MDCT scans revealed HALT in 1 patient (1.4%) at discharge, 7 (10.0%) at 6 months, and 10 (14.3%) at 1 year post-transcatheter aortic valve replacement cumulatively. The degree of leaflet immobility correlated with the HALT area on 4-dimensional MDCT (r = 0.68) on the basis of data from 10 patients. HALT was associated with male sex (70% vs. 25%; p = 0.008) and larger sinus of Valsalva (31.0 +/- 2.0 mm vs. 28.6 +/- 2.6 mm; p = 0.005). HALT was found in 3 of 49 patients with a 23-mm bioprosthesis and in 7 of 21 patients with a 26-mm bioprosthesis (6.1% vs. 33.3%; p = 0.006). D-dimer levels were significantly increased in the HALT group at the 6-month (2.3 mu g/ml [interquartile range (IQR): 2.1 to 6.1 mu g/ml] vs. 1.1 mu g/ml [IQR: 0.8 to 2.2 mu g/ml]; p = 0.002) and 1-year (2.7 mu g/ml [IQR: 1.7 to 4.8 mu g/ml] vs. 1.2 mu g/ml [IQR: 0.9 to 2.1 mu g/ml]; p = 0.006) follow-ups, despite no differences at discharge. The pressure gradient was decreased in the HALT group at the 1-year follow-up (8.3 +/- 0.8 mm Hg vs. 11.1 +/- 4.9 mm Hg; p = 0.005). After detecting HALT, additional anticoagulation therapy was not administered. Clinical outcomes, including all-cause mortality (0% vs. 1.7%; p = 1.00) and stroke (0% vs. 0%; p = 1.00), were similar between the groups. CONCLUSIONS HALT with reduced leaflet motion was not rare but usually subclinical. Valve hemodynamics and mid-term outcomes were uneventful even without additional anticoagulant therapy in our limited number of cases. Male sex, larger sinus and bioprosthesis size, and elevated D-dimer levels during follow-up were associated with this phenomenon. (C) 2017 by the American College of Cardiology Foundation.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 26 条
[1]   Transcatheter Aortic-Valve Replacement with a Self-Expanding Prosthesis [J].
Adams, David H. ;
Popma, Jeffrey J. ;
Reardon, Michael J. ;
Yakubov, Steven J. ;
Coselli, Joseph S. ;
Deeb, G. Michael ;
Gleason, Thomas G. ;
Buchbinder, Maurice ;
Hermiller, James, Jr. ;
Kleiman, Neal S. ;
Chetcuti, Stan ;
Heiser, John ;
Merhi, William ;
Zorn, George ;
Tadros, Peter ;
Robinson, Newell ;
Petrossian, George ;
Hughes, G. Chad ;
Harrison, J. Kevin ;
Conte, John ;
Maini, Brijeshwar ;
Mumtaz, Mubashir ;
Chenoweth, Sharla ;
Oh, Jae K. .
NEW ENGLAND JOURNAL OF MEDICINE, 2014, 370 (19) :1790-1798
[2]   Early Anticoagulation of Bioprosthetic Aortic Valves in Older Patients Results From the Society of Thoracic Surgeons Adult Cardiac Surgery National Database [J].
Brennan, J. Matthew ;
Edwards, Fred H. ;
Zhao, Yue ;
O'Brien, Sean ;
Booth, Michael E. ;
Dokholyan, Rachel S. ;
Douglas, Pamela S. ;
Peterson, Eric D. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (11) :971-977
[3]  
Carrie D, 2010, EUR HEART J, V31, P167
[4]   Thrombus Formation Following Transcatheter Aortic Valve Replacement [J].
De Marchena, Eduardo ;
Mesa, Julian ;
Pomenti, Sydney ;
Kall, Christian Marin y ;
Marincic, Ximena ;
Yahagi, Kazuyuki ;
Ladich, Elena ;
Kutz, Robert ;
Aga, Yaar ;
Ragosta, Michael ;
Chawla, Atul ;
Ring, Michael E. ;
Virmani, Renu .
JACC-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (05) :728-739
[5]   Bioprosthetic Valve Thrombosis Versus Structural Failure Clinical and Echocardiographic Predictors [J].
Egbe, Alexander C. ;
Pislaru, Sorin V. ;
Pellikka, Patricia A. ;
Poterucha, Joseph T. ;
Schaff, Hartzell V. ;
Maleszewski, Joseph J. ;
Connolly, Heidi M. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 66 (21) :2285-2294
[6]   Sixty-Four-Section Cardiac Computed Tomography in Mechanical Prosthetic Heart Valve Dysfunction [J].
Gunduz, Sabahattin ;
Ozkan, Mehmet ;
Kalcik, Macit ;
Gursoy, Ozan Mustafa ;
Astarcioglu, Mehmet Ali ;
Karakoyun, Suleyman ;
Aykan, Ahmet Cagri ;
Biteker, Murat ;
Gokdeniz, Tayyar ;
Kaya, Hasan ;
Yesin, Mahmut ;
Duran, Nilufer Eksi ;
Sevinc, Deniz ;
Guneysu, Tahsin .
CIRCULATION-CARDIOVASCULAR IMAGING, 2015, 8 (12)
[7]   Major Thrombocytopenia after Balloon-Expandable Transcatheter Aortic Valve Replacement: Prognostic Implications and Comparison to Surgical Aortic Valve Replacement [J].
Jilaihawi, Hasan ;
Doctor, Niraj ;
Chakravarty, Tarun ;
Kashif, Mohammad ;
Mirocha, James ;
Cheng, Wen ;
Lill, Michael ;
Nakamura, Mamoo ;
Gheorghiu, Mitch ;
Makkar, Raj R. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2015, 85 (01) :130-137
[8]   5-year outcomes of transcatheter aortic valve replacement compared with standard treatment for patients with inoperable aortic stenosis (PARTNER 1): a randomised controlled trial [J].
Kapadia, Samir R. ;
Leon, Martin B. ;
Makkar, Raj R. ;
Tuzcu, E. Murat ;
Svensson, Lars G. ;
Kodali, Susheel ;
Webb, John G. ;
Mack, Michael J. ;
Douglas, Pamela S. ;
Thourani, Vinod H. ;
Babaliaros, Vasilis C. ;
Herrmann, Howard C. ;
Szeto, Wilson Y. ;
Pichard, Augusto D. ;
Williams, Mathew R. ;
Fontana, Gregory P. ;
Miller, D. Craig ;
Anderson, William N. ;
Akin, Jodi J. ;
Davidson, Michael J. ;
Smith, Craig R. .
LANCET, 2015, 385 (9986) :2485-2491
[9]   Updated standardized endpoint definitions for transcatheter aortic valve implantation: The Valve Academic Research Consortium-2 consensus document [J].
Kappetein, A. Pieter ;
Head, Stuart J. ;
Genereux, Philippe ;
Piazza, Nicolo ;
van Mieghem, Nicolas M. ;
Blackstone, Eugene H. ;
Brott, Thomas G. ;
Cohen, David J. ;
Cutlip, Donald E. ;
van Es, Gerrit-Anne ;
Hahn, Rebecca T. ;
Kirtane, Ajay J. ;
Krucoff, Mitchell W. ;
Kodali, Susheel ;
Mack, Michael J. ;
Mehran, Roxana ;
Rodes-Cabau, Josep ;
Vranckx, Pascal ;
Webb, John G. ;
Windecker, Stephan ;
Serruys, Patrick W. ;
Leon, Martin B. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 145 (01) :6-23
[10]   Treatment and Clinical Outcomes of Transcatheter Heart Valve Thrombosis [J].
Latib, Azeem ;
Naganuma, Toru ;
Abdel-Wahab, Mohamed ;
Danenberg, Haim ;
Cota, Linda ;
Barbanti, Marco ;
Baumgartner, Helmut ;
Finkelstein, Ariel ;
Legrand, Victor ;
Suarez de Lezo, Jose ;
Kefer, Joelle ;
Messika-Zeitoun, David ;
Richardt, Gert ;
Stabile, Eugenio ;
Kaleschke, Gerrit ;
Vahanian, Alec ;
Laborde, Jean-Claude ;
Leon, Martin B. ;
Webb, John G. ;
Panoulas, Vasileios F. ;
Maisano, Francesco ;
Alfieri, Ottavio ;
Colombo, Antonio .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (04)