Accelerated Bilateral Dynamic Contrast-Enhanced 3D Spiral Breast MRI Using TSENSE

被引:12
作者
Han, Misung [1 ,2 ]
Daniel, Bruce L. [1 ]
Hargreaves, Brian A. [1 ]
机构
[1] Stanford Univ, Dept Radiol, Lucas MRS I Ctr, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
基金
美国国家卫生研究院;
关键词
bilateral breast; TSENSE; dynamic contrast-enhanced MRI; parallel imaging; rapid; MRI;
D O I
10.1002/jmri.21427
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the ability of adaptive sensitivity encoding incorporating temporal filtering (TSENSE) to accelerate bilateral dynamic contrast-enhanced (DCE) 3D breast MRI. Materials and Methods: Bilateral DCE breast magnetic resonance imaging (MRI) exams were performed using a dual-band water-only excitation and a "stack-of-spirals" imaging trajectory. TSENSE was applied in the slab direction with an acceleration factor of 2. Four different techniques for sensitivity map calculation were compared by analyzing resultant contrast uptake curves qualitatively and quantitatively for 10 patient datasets. In addition, image quality and temporal resolution were compared between unaccelerated and TSENSE Images. Results: TSENSE can increase temporal resolution by a factor of 2 in DCE imaging, providing better depiction of contrast uptake curves and good image quality. Of the different methods tested, calculation of static sensitivity maps by averaging late postcontrast frames yields the lowest aliasing artifact level based on ROI analysis. Conclusion: TSENSE acceleration combined with 3D spiral imaging is very time-efficient, providing 11-second temporal resolution and 1.1 x 1.1 x 3 mm(3) spatial resolution over a 20 x 20 x 10 cm(3) field of view for each breast.
引用
收藏
页码:1425 / 1434
页数:10
相关论文
共 37 条
  • [1] HIGH-SPEED SPIRAL-SCAN ECHO PLANAR NMR IMAGING .1.
    AHN, CB
    KIM, JH
    CHO, ZH
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1986, 5 (01) : 2 - 7
  • [2] Beatty PJ, 2007, P JOINT ANN M ISMRM
  • [3] Consistent fat suppression with compensated spectral-spatial pulses
    Block, W
    Pauly, J
    Kerr, A
    Nishimura, D
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (02) : 198 - 206
  • [4] MR CHARACTERIZATION OF SUSPICIOUS BREAST-LESIONS WITH A GADOLINIUM-ENHANCED TURBOFLASH SUBTRACTION TECHNIQUE
    BOETES, C
    BARENTSZ, JO
    MUS, RD
    VANDERSLUIS, RF
    VANERNING, LJTO
    HENDRIKS, JHCL
    HOLLAND, R
    RUYS, SHJ
    [J]. RADIOLOGY, 1994, 193 (03) : 777 - 781
  • [5] Dynamic autocalibrated parallel imaging using temporal GRAPPA (TGRAPPA)
    Breuer, FA
    Kellman, P
    Griswold, MA
    Jakob, PM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (04) : 981 - 985
  • [6] Partial fourier partially parallel imaging
    Bydder, M
    Robson, MD
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (06) : 1393 - 1401
  • [7] High frame-rate simultaneous bilateral breast DCE-MRI
    Dougherty, Lawrence
    Isaac, Gamaliel
    Rosen, Mark A.
    Nunes, Linda W.
    Moate, Peter J.
    Boston, Raymond C.
    Schnall, Mitchell D.
    Song, Hee Kwon
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (01) : 220 - 225
  • [8] BREAST MR-IMAGING WITH COMMERCIALLY AVAILABLE TECHNIQUES - RADIOLOGIC-PATHOLOGICAL CORRELATION
    FOBBEN, ES
    RUBIN, CZ
    KALISHER, L
    DEMBNER, AG
    SELTZER, MH
    SANTORO, EJ
    [J]. RADIOLOGY, 1995, 196 (01) : 143 - 152
  • [9] SENSE imaging of the breast
    Friedman, PD
    Swaminathan, SV
    Smith, R
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 184 (02) : 448 - 451
  • [10] 3-POINT DIXON TECHNIQUE FOR TRUE WATER FAT DECOMPOSITION WITH BO INHOMOGENEITY CORRECTION
    GLOVER, GH
    SCHNEIDER, E
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (02) : 371 - 383