DOSE REDUCTION IN CHEST CT EXAMINATION

被引:14
作者
Sulieman, A. [1 ,2 ]
Tammam, N. [2 ]
Alzimami, K. [3 ]
Elnour, A. M. [2 ]
Babikir, E. [3 ]
Alfuraih, A. [3 ]
机构
[1] Prince Sattam bin Abdulaziz Univ, Coll Appl Med Sci, Radiol & Med Imaging Dept, Alkharj, Saudi Arabia
[2] Sudan Univ Sci & Technol, Coll Med Radiol Sci, Khartoum, Sudan
[3] King Saud Univ, Coll Appl Sci, Radiol Sci Dept, Riyadh, Saudi Arabia
关键词
AUTOMATIC EXPOSURE CONTROL; COMPUTED-TOMOGRAPHY; RADIATION;
D O I
10.1093/rpd/ncv123
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Computed tomography (CT) examinations involve relatively high doses to patients. The objectives of this study were to optimise the radiation dose for patient during CT chest scan and to estimate the lifetime cancer risk. A total of 50 patients were studied: control group (A) (38 patients) and optimisation group (B) (12 patients). The optimisation protocol was based on CT pitch increment and lowering tube current. The mean volume CT dose index (CTDIvol) was 21.17 mGy and dose length product (DLP) was 839.0 mGy cm for Group A, and CTDIvol was 8.3 mGy and DLP was 339.7 for Group B. The overall cancer risk was estimated to be 8.0 and 3.0 cancer incidence per million for Groups A and B, respectively. The patient dose optimisation during CT chest was investigated. Lowering tube current and pitch increment achieved a radiation dose reduction of up to 60 % without compromising the diagnostic findings.
引用
收藏
页码:185 / 189
页数:5
相关论文
共 23 条
[1]  
[Anonymous], Ann. ICRP
[2]  
[Anonymous], 2000, MANAGING PATIENT DOS
[3]  
[Anonymous], 2006, HLTH RISKS EXPOSURE
[4]   Diagnostic radiology in Norway-trends in examination frequency and collective effective dose [J].
Borretzen, Ingelin ;
Lysdahl, Kristin Bakke ;
Olerud, Hilde Merete .
RADIATION PROTECTION DOSIMETRY, 2007, 124 (04) :339-347
[5]  
Bozovic P., 2013, S JE E, V10, P31
[6]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[7]  
Commission European, 2000, 16262 EUR EN
[8]   Radiation dose evaluation in 64-slice CT examinations with adult and paediatric anthropomorphic phantoms [J].
Fujii, K. ;
Aoyama, T. ;
Yamauchi-Kawaura, C. ;
Koyama, S. ;
Yamauchi, M. ;
Ko, S. ;
Akahane, K. ;
Nishizawa, K. .
BRITISH JOURNAL OF RADIOLOGY, 2009, 82 (984) :1010-1018
[9]   CT Radiation Dose Optimization and Estimation: an Update for Radiologists [J].
Goo, Hyun Woo .
KOREAN JOURNAL OF RADIOLOGY, 2012, 13 (01) :1-11
[10]  
Hart D., 1994, 262 NRPB