Technology and New Fluorescence Flow Cytometry Parameters in Hematological Analyzers

被引:10
作者
Arneth, Borros M. [1 ]
Menschikowki, Mario [1 ]
机构
[1] Tech Univ Dresden, Carl Gustav Carus Univ Hosp, Inst Clin Chem & Lab Med, D-01307 Dresden, Germany
关键词
hematology; PROGNOSTIC-SIGNIFICANCE; SYSMEX XE-2100; BLOOD-CELLS; NEUT-X; IMMATURE; ERYTHROBLASTS;
D O I
10.1002/jcla.21747
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
BackgroundModern hematological analyzers offer a series of new tests in addition to the differential blood cell count. Here, we provide a short overview of the technique and the new tests included in the hematological analyzers manufactured by the company Sysmex (Kobe, Japan). As introduced here, the resulting new extended blood cell count allows for the quantification of DNA- and RNA-rich, activated and/or precursor leukocyte subpopulations. MethodsTo compare the different methods of blood cell counting, repetitive cell counting is carried out by hematological experts using microscopy and using the XE-5000 hematological analyzer. ResultsThe hematological analyzer delivers more-accurate results with respect to normal cells but microscopy is suited better to recognize and count pathological cells. ConclusionWith the new hematological analyzers, several new hematological tests are made available as screening tools that were not possible previously using standard cell-counting procedures.
引用
收藏
页码:175 / 183
页数:9
相关论文
共 19 条
[1]   Immature granulocyte measurement using the Sysmex XE-2100 - Relationship to infection and sepsis [J].
Ansari-Lari, MA ;
Kickler, TS ;
Borowitz, MJ .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2003, 120 (05) :795-799
[2]   Evaluation of the XE-5000 for the automated analysis of blood cells in cerebrospinal fluid [J].
Boer, Klas ;
Deufel, Thomas ;
Reinhoefer, Mike .
CLINICAL BIOCHEMISTRY, 2009, 42 (7-8) :684-691
[3]   Immature platelet fraction measurement: a future guide to platelet transfusion requirement after haematopoietic stem cell transplantation [J].
Briggs, C ;
Hart, D ;
Kunka, S ;
Oguni, S ;
Machin, SJ .
TRANSFUSION MEDICINE, 2006, 16 (02) :101-109
[4]   Assessment of an immature platelet fraction (IPF) in peripheral thrombocytopenia [J].
Briggs, C ;
Kunka, S ;
Hart, D ;
Oguni, S ;
Machin, SJ .
BRITISH JOURNAL OF HAEMATOLOGY, 2004, 126 (01) :93-99
[5]   New quantitative parameters on a recently introduced automated blood cell counter -: the XE 2100™ [J].
Briggs, C ;
Harrison, P ;
Grant, D ;
Staves, J ;
Machin, SJ .
CLINICAL AND LABORATORY HAEMATOLOGY, 2000, 22 (06) :345-350
[6]  
Briggs Carol, 2003, Lab Hematol, V9, P117
[7]  
Cremer M, 2008, BRIT J HAEMATOL, V144, P613
[8]   Evaluation of the new body fluid mode on the Sysmex XE-5000 for counting leukocytes and erythrocytes in cerebrospinal fluid and other body fluids [J].
de Jonge, Robert ;
Brouwer, Rob ;
de Graaf, Marieke T. ;
Luitwieler, Ronald L. ;
Fleming, Cherina ;
de Frankrijker-Merkestijn, Magda ;
Smitt, Peter A. E. Sillevis ;
Boonstra, Joke G. ;
Lindemans, Jan .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2010, 48 (05) :665-675
[9]   Immature platelet fraction (IPF) in hospitalized patients with neutrophilia and suspected bacterial infection [J].
Di Mario, Antonella ;
Garzia, Mariagrazia ;
Leone, Fiammetta ;
Arcangeli, Andrea ;
Pagano, Livio ;
Zini, Gina .
JOURNAL OF INFECTION, 2009, 59 (03) :201-206
[10]   Automated enumeration of immature Granulocytes [J].
Fernandes, Bernard ;
Hamaguchi, Yukio .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2007, 128 (03) :454-463