Articular Cartilage Degeneration Following the Treatment of Focal Cartilage Defects with Ceramic Metal Implants and Compared with Microfracture

被引:49
作者
Custers, R. J. H. [1 ]
Saris, D. B. F. [1 ]
Dhert, W. J. A. [1 ]
Verbout, A. J. [1 ]
van Rijen, M. H. P. [1 ]
Mastbergen, S. C. [2 ]
Lafeber, F. P. J. G. [2 ]
Creemers, L. B. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Orthopaed, NL-3508 GA Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Dept Rheumatol & Clin Immunol, NL-3508 GA Utrecht, Netherlands
关键词
CONTINUOUS PASSIVE MOTION; AUTOGENOUS PERIOSTEAL GRAFTS; FULL-THICKNESS DEFECTS; OXIDIZED ZIRCONIUM; COBALT-CHROMIUM; JOINT SURFACES; KNEE-JOINTS; RABBIT; REPAIR; MODEL;
D O I
10.2106/JBJS.H.00668
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Localized cartilage defects are frequently associated with joint pain, reduced function, and a predisposition to the development of osteoarthritis. The purposes of the current study were to investigate the feasibility of the application of defect-sized femoral implants for the treatment of localized cartilage defects and to compare this treatment, in terms of joint degeneration, with the use of microfiracture in a goat model of established cartilage defects. Methods: In nine Dutch milk goats, a defect in the medial femoral condyle was created in both knees. After ten weeks, the knees were randomly treated by microfracture or by placement of an oxidized zirconium implant. At twenty-six weeks after surgery, the animals were killed. The joints were evaluated macroscopically. Implant osseointegration was measured by automated histomorphometry, and cartilage repair (after microfracture) was scored histologically. Cartilage quality was analyzed macroscopically and histologically. Glycosaminoglycan content and release were measured by alcian blue assay, and the synthesis and release of newly formed glycosaminoglycans were measured by liquid scintillation analysis of the incorporation of (SO42-)-S-35 in tissue and medium. Results: The mean bone-implant contact (and standard error) was appropriate (14.6%+/- 5.4%), and the amount of bone surrounding the implantwas extensive (mean, 40.3%+/- 4.0%). The healing of the microfracture-treated defects was extensive, although not complete (mean, 18.38 +/- 0.43 points of a maximum possible score of 24 points). The macroscopic cartilage evaluation did not show any significant differences between the treatments. On histologic evaluation, the cartilage of the medial tibial plateau articulating directly against the treated defects demonstrated significantly more degeneration in the microfracture-treated knees than in the implant-treated knees (p < 0.05). This was in accordance with a significantly higher glycosaminoglycan content, higher synthetic activity, and decreased glycosaminoglycan release of the medial tibial plateau cartilage of the implant-treated knees (p < 0.05 for all). On histological analysis, degeneration was also found in the cartilage of the lateral tibial plateau and condyle, but no significant difference was found between the treatments. Conclusions: Both microfracture and the use of implants as a treatment for established localized cartilage defects in the medial femoral condyle caused considerable (p < 0.05) degeneration of the directly articulating cartilage as well as in more remote sites in the knee. However, in the medial tibial plateau, the metal implants caused less damage than the microfiracture technique. Clinical Relevance: Although this study shows that small metal implants may be more suitable than microfracture in the treatment of localized cartilage defects in the knee, the generalized degeneration found following both treatments should be addressed first.
引用
收藏
页码:900 / 910
页数:11
相关论文
共 34 条
  • [1] *ARTHR, ARTHR HEMICAP SYST
  • [2] Surface arthroplasty for osteonecrosis of the hip -: Hemiresurfacing versus metal-on-metal hybrid resurfacing
    Beaulé, PE
    Amstutz, HC
    Le Duff, M
    Dorey, F
    [J]. JOURNAL OF ARTHROPLASTY, 2004, 19 (08) : 54 - 58
  • [3] ButnariuEphrat M, 1996, CLIN ORTHOP RELAT R, P234
  • [4] Articular damage caused by metal plugs in a rabbit model for treatment of localized cartilage defects
    Clusters, R. J. H.
    Dhert, W. J. A.
    van Rijen, M. H. P.
    Verbout, A. J.
    Creemers, L. B.
    Saris, D. B. F.
    [J]. OSTEOARTHRITIS AND CARTILAGE, 2007, 15 (08) : 937 - 945
  • [5] Reduced wear with oxidized zirconium femoral heads
    Good, V
    Ries, M
    Barrack, RL
    Widding, K
    Hunter, G
    Heuer, D
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A : 105 - 110
  • [6] Articular cartilage repair: basic science and clinical progress. A review of the current status and prospects
    Hunziker, EB
    [J]. OSTEOARTHRITIS AND CARTILAGE, 2002, 10 (06) : 432 - 463
  • [7] Safety of, and biological and functional response to, a novel metallic implant for the management of focal full-thickness cartilage defects: Preliminary assessment in an animal model out to 1 year
    Kirker-Head, CA
    Van Sickle, DC
    Ek, SW
    McCool, JC
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2006, 24 (05) : 1095 - 1108
  • [8] Autologous chondrocyte implantation compared with microfracture in the knee - A randomized trial
    Knutsen, G
    Engebretsen, L
    Ludvigsen, TC
    Drogset, JO
    Grontvedt, T
    Solheim, E
    Strand, T
    Roberts, S
    Isaksen, V
    Johansen, C
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (03) : 455 - 464
  • [9] LAFEBER FPJG, 1992, AM J PATHOL, V140, P1421
  • [10] BIOCHEMICAL AND METABOLIC ABNORMALITIES IN ARTICULAR CARTILAGE FROM OSTEO-ARTHRITIC HUMAN HIPS .2. CORRELATION OF MORPHOLOGY WITH BIOCHEMICAL AND METABOLIC DATA
    MANKIN, HJ
    DORFMAN, H
    LIPPIELL.L
    ZARINS, A
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1971, A 53 (03) : 523 - +