Preparation of GOD/Sol-Gel Silica Film on Prussian Blue Modified Electrode for Glucose Biosensor Application

被引:25
|
作者
Liang, Ru-Ping [1 ,2 ]
Jiang, Jing-Li [1 ,2 ]
Qiu, Jian -Ding [1 ,2 ,3 ]
机构
[1] Nanchang Univ, Dept Chem, Nanchang 330031, Peoples R China
[2] Nanchang Univ, Inst Adv Study, Nanchang 330031, Peoples R China
[3] Pingxiang Coll, Dept Chem Engn, Pingxiang 337055, Peoples R China
基金
中国国家自然科学基金;
关键词
Glucose biosensor; Prussian blue; Sol-gel; Electrochemical deposition;
D O I
10.1002/elan.200804370
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel amperometric glucose biosensor was fabricated by in situ incorporating glucose oxidase (GOD) within the sol-gel silica film on a Prussian blue (PB) modified electrode. The method is simple and controllable, which combined the merits of in situ immobilizing biomolecules in sol-gel silica film by electrochemical method and the synergic catalysis effects of PB and GOD molecules. Scanning electron microscopy (SEM) showed that the GOD/sol-gel silica film was homogeneous with a large number of three-dimensional nanopores, which not only enhanced mass transport, but also maintained the active configuration of the enzyme molecule and prevented the leakage of enzyme, therefore improved the stability and sensitivity of the biosensor. The fabricated biosensor showed fast response time (10s), high sensitivity (26.6 mA cm(-2) M-1), long-term stability, good suppression of interference, and linear range of 0.01 mM - 5.8 mM with a low detection limit of 0.94 mu M for the detection of glucose. In addition, the biosensor was successfully applied to determine glucose in human serum samples.
引用
收藏
页码:2642 / 2648
页数:7
相关论文
共 50 条
  • [41] Sol-Gel/Chitosan/Gold Nanoparticle-Modified Electrode in Mediated Bacterial Biosensor
    Habib, Omer
    Demirkol, Dilek Odaci
    Timur, Suna
    FOOD ANALYTICAL METHODS, 2012, 5 (02) : 188 - 194
  • [42] Sol-gel derived iridium composite glucose biosensor
    Tian, FM
    Zhu, GY
    SENSORS AND ACTUATORS B-CHEMICAL, 2002, 86 (2-3): : 266 - 270
  • [43] Electrochemical impedance spectra of prussian blue film modified platinum electrode
    Zhang, FF
    Wu, XQ
    Meng, XY
    Guo, XM
    Zhang, ZR
    ACTA PHYSICO-CHIMICA SINICA, 2001, 17 (09) : 788 - 791
  • [44] A new glucose biosensor based on sandwich configuration of organically modified sol-gel glass
    Pandey, PC
    Upadhyay, S
    Pathak, HC
    ELECTROANALYSIS, 1999, 11 (01) : 59 - 64
  • [45] Enhanced stability of a Prussian blue/sol-gel composite for electrochemical determination of hydrogen peroxide
    Doroftei, Florica
    Pinteala, Tudor
    Arvinte, Adina
    MICROCHIMICA ACTA, 2014, 181 (1-2) : 111 - 120
  • [46] Electrochemical determination of maltol in beverages with glassy carbon electrode and its silica sol-gel modified electrode
    Di, JW
    Bi, SP
    Zhang, F
    TALANTA, 2004, 63 (02) : 265 - 272
  • [47] In situ immobilization of glucose oxidase in chitosan-gold nanoparticle hybrid film on Prussian Blue modified electrode for high-sensitivity glucose detection
    Xue, Min-Hua
    Xu, Qin
    Zhou, Mi
    Zhu, Jun-Jie
    ELECTROCHEMISTRY COMMUNICATIONS, 2006, 8 (09) : 1468 - 1474
  • [48] GLUCOSE SENSOR WITH AN ENZYME-ENTRAPPED SILICA-GEL FILM PREPARED BY A SOL-GEL METHOD
    YAO, T
    HARADA, I
    NAKAHARA, T
    BUNSEKI KAGAKU, 1995, 44 (11) : 927 - 932
  • [49] Disposable superoxide anion biosensor based on superoxide dismutase entrapped in silica sol-gel matrix at gold nanoparticles modified ITO electrode
    Wang, Yuan
    Wu, Ying
    Wang, Jianwen
    Di, Junwei
    BIOPROCESS AND BIOSYSTEMS ENGINEERING, 2009, 32 (04) : 531 - 536
  • [50] Sensor and biosensor preparation, optimisation and applications of Prussian Blue modified electrodes
    Ricci, F
    Palleschi, G
    BIOSENSORS & BIOELECTRONICS, 2005, 21 (03) : 389 - 407