Preparation of GOD/Sol-Gel Silica Film on Prussian Blue Modified Electrode for Glucose Biosensor Application

被引:25
|
作者
Liang, Ru-Ping [1 ,2 ]
Jiang, Jing-Li [1 ,2 ]
Qiu, Jian -Ding [1 ,2 ,3 ]
机构
[1] Nanchang Univ, Dept Chem, Nanchang 330031, Peoples R China
[2] Nanchang Univ, Inst Adv Study, Nanchang 330031, Peoples R China
[3] Pingxiang Coll, Dept Chem Engn, Pingxiang 337055, Peoples R China
基金
中国国家自然科学基金;
关键词
Glucose biosensor; Prussian blue; Sol-gel; Electrochemical deposition;
D O I
10.1002/elan.200804370
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel amperometric glucose biosensor was fabricated by in situ incorporating glucose oxidase (GOD) within the sol-gel silica film on a Prussian blue (PB) modified electrode. The method is simple and controllable, which combined the merits of in situ immobilizing biomolecules in sol-gel silica film by electrochemical method and the synergic catalysis effects of PB and GOD molecules. Scanning electron microscopy (SEM) showed that the GOD/sol-gel silica film was homogeneous with a large number of three-dimensional nanopores, which not only enhanced mass transport, but also maintained the active configuration of the enzyme molecule and prevented the leakage of enzyme, therefore improved the stability and sensitivity of the biosensor. The fabricated biosensor showed fast response time (10s), high sensitivity (26.6 mA cm(-2) M-1), long-term stability, good suppression of interference, and linear range of 0.01 mM - 5.8 mM with a low detection limit of 0.94 mu M for the detection of glucose. In addition, the biosensor was successfully applied to determine glucose in human serum samples.
引用
收藏
页码:2642 / 2648
页数:7
相关论文
共 50 条
  • [21] Electrochemistry of Prussian Blue in silica sol-gel electrolytes doped with polyamidoamine dendrimers
    Zamponi, S
    Kijak, AM
    Sommer, AJ
    Marassi, R
    Kulesza, PJ
    Cox, JA
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2002, 6 (08) : 528 - 533
  • [22] Electrochemistry of Prussian Blue in silica sol-gel electrolytes doped with polyamidoamine dendrimers
    Silvia Zamponi
    Anna M. Kijak
    André J. Sommer
    Roberto Marassi
    Pawel J. Kulesza
    James A. Cox
    Journal of Solid State Electrochemistry, 2002, 6 : 528 - 533
  • [23] Glucose biosensor based on entrapment of glucose oxidase and myoglobin in silica gel by the sol-gel method
    Zaitoun, MA
    SPECTROSCOPY-AN INTERNATIONAL JOURNAL, 2005, 19 (02): : 119 - 126
  • [24] Sol-gel-derived prussian blue-silicate amperometric glucose biosensor
    Bharathi, S
    Lev, O
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2000, 89 (2-3) : 209 - 216
  • [25] Sol-gel-derived prussian blue-silicate amperometric glucose biosensor
    Subramanian Bharathi
    Ovadia Lev
    Applied Biochemistry and Biotechnology, 2000, 89 : 209 - 216
  • [26] Redox modified silicate films: Anthraquinone and Prussian blue modified sol-gel electrodes
    Bharathi, S
    Wu, ZB
    Lev, O
    SOL-GEL OPTICS IV, 1997, 3136 : 127 - 133
  • [27] Study of the nano-size silica sol-gel film as the matrix of chemically modified electrode
    Tu, YF
    Di, JW
    Chen, XJ
    JOURNAL OF SOL-GEL SCIENCE AND TECHNOLOGY, 2005, 33 (02) : 187 - 191
  • [28] DNA as a support for glucose oxidase immobilization at Prussian blue-modified glassy carbon electrode in biosensor preparation
    Kafi, A. K. M.
    Lee, Dong-Yun
    Park, Sang-Hyun
    Kwon, Young-Soo
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2006, 6 (11) : 3539 - 3542
  • [29] Organically modified sol-gel/chitosan composite based glucose biosensor
    Chen, X
    Jia, JB
    Dong, SJ
    ELECTROANALYSIS, 2003, 15 (07) : 608 - 612
  • [30] Preparation of biomimetic superhydrophobic silica film by sol-gel technique
    Guo, ZG
    Zhou, F
    Liu, WM
    ACTA CHIMICA SINICA, 2006, 64 (08) : 761 - 766