Improving cerebral blood flow quantification for arterial spin labeled perfusion MRI by removing residual motion artifacts and global signal fluctuations

被引:123
作者
Wang, Ze [1 ,2 ]
机构
[1] Univ Penn, Treatment Res Ctr, Perelman Sch Med, Dept Psychiat, Philadelphia, PA 19104 USA
[2] Univ Penn, Sch Engn & Appl Sci, Dept Bioengn, Philadelphia, PA 19104 USA
关键词
Arterial spin labeling; Motion correction; CBF; Global signal; Test-retest stability; Temporal SNR; NOISE CORRECTION; FMRI; BOLD; REDUCTION; NETWORK; MODEL;
D O I
10.1016/j.mri.2012.05.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Denoising is critical to improving the quality and stability of cerebral blood flow (CBF) quantification in arterial spin labeled (ASL) perfusion magnetic resonance imaging (MRI) due to the intrinsic low signal-to-noise-ratio (SNR) of ASL data. Previous studies have been focused on reducing the spatial or temporal noise using standard filtering techniques, and less attention has been paid to two global nuisance effects, the residual motion artifacts and the global signal fluctuations. Since both nuisances affect the whole brain, removing them in advance should enhance the CBF quantification quality for ASL MRI. The purpose of this paper was to assess this potential benefit. Three methods were proposed to suppress each or both of the two global nuisances. Their performances for CBF quantification were validated using ASL data acquired from 13 subjects. Evaluation results showed that covarying out both global nuisances significantly improved temporal SNR and test-retest stability of CBF measurement. Although the concept of removing both nuisances is not technically novel per se, this paper clearly showed the benefits for ASL CBF quantification. Dissemination of the proposed methods in a free ASL data processing toolbox should be of interest to a broad range of ASL users. (C) 2012 Elsevier Inc. All rights reserved.
引用
收藏
页码:1409 / 1415
页数:7
相关论文
共 31 条
[1]   Experimental design and the relative sensitivity of BOLD and perfusion fMRI [J].
Aguirre, GK ;
Detre, JA ;
Zarahn, E ;
Alsop, DC .
NEUROIMAGE, 2002, 15 (03) :488-500
[2]   A component based noise correction method (CompCor) for BOLD and perfusion based fMRI [J].
Behzadi, Yashar ;
Restom, Khaled ;
Liau, Joy ;
Liu, Thomas T. .
NEUROIMAGE, 2007, 37 (01) :90-101
[3]   Denoising of arterial spin labeling data: wavelet-domain filtering compared with Gaussian smoothing [J].
Bibic, Adnan ;
Knutsson, Linda ;
Stahlberg, Freddy ;
Wirestam, Ronnie .
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2010, 23 (03) :125-137
[4]   The brain's default network - Anatomy, function, and relevance to disease [J].
Buckner, Randy L. ;
Andrews-Hanna, Jessica R. ;
Schacter, Daniel L. .
YEAR IN COGNITIVE NEUROSCIENCE 2008, 2008, 1124 :1-38
[5]   Effects of model-based physiological noise correction on default mode network anti-correlations and correlations [J].
Chang, Catie ;
Glover, Gary H. .
NEUROIMAGE, 2009, 47 (04) :1448-1459
[6]   Mapping resting-state functional connectivity using perfusion MRI [J].
Chuang, Kai-Hsiang ;
Van Gelderen, Peter ;
Merkle, Hellmut ;
Bodurka, Jerzy ;
Ikonomidou, Vasiliki N. ;
Koretsky, Alan P. ;
Duyn, Jeff H. ;
Talagala, S. Lalith .
NEUROIMAGE, 2008, 40 (04) :1595-1605
[7]   Removal of confounding effects of global signal in functional MRI analyses [J].
Desjardins, AE ;
Kiehl, KA ;
Liddle, PF .
NEUROIMAGE, 2001, 13 (04) :751-758
[8]   PERFUSION IMAGING [J].
DETRE, JA ;
LEIGH, JS ;
WILLIAMS, DS ;
KORETSKY, AP .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (01) :37-45
[9]   Spontaneous fluctuations in brain activity observed with functional magnetic resonance imaging [J].
Fox, Michael D. ;
Raichle, Marcus E. .
NATURE REVIEWS NEUROSCIENCE, 2007, 8 (09) :700-711
[10]   The Global Signal and Observed Anticorrelated Resting State Brain Networks [J].
Fox, Michael D. ;
Zhang, Dongyang ;
Snyder, Abraham Z. ;
Raichle, Marcus E. .
JOURNAL OF NEUROPHYSIOLOGY, 2009, 101 (06) :3270-3283