FI-spectrophotometric determination of uranium after preconcentration on an anion exchange resin

被引:9
|
作者
Nisa, Qamar Un [1 ]
Ali, Akbar [2 ]
Khan, Muhammad Haleem [1 ]
机构
[1] Univ Azad Jammu & Kashmir AJK, Dept Chem, Muzaffarabad, Pakistan
[2] Pakistan Inst Nucl Sci & Technol, Div Chem, Islamabad, Pakistan
关键词
Uranium; Online preconcentration; Anion exchange resin; Spectrophotometry; Arsenazo-III; FLOW-INJECTION ANALYSIS; SYSTEM; SEPARATION; THORIUM; SAMPLES;
D O I
10.1007/s10967-012-2278-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An economical, fast, sensitive and selective method for the determination of uranium (VI) from sulfate media based on the flow injection on-line preconcentration in a minicolumn having amberlite IRA-402 (strong anion exchange) resin is described. Uranium (VI) was selectively adsorbed on the resin as uranyl trisulfate complex from aqueous solution of pH 2 in the minicolumn (2.56 mm i.d. and 7.5 cm in length) at a flow rate of 10 ml min(-1). The adsorbed uranyl trisulfate complex was eluted by HClO4 (0.1 mol l(-1), 6.5 ml min(-1)) and mixed with arsenazo-III (0.05 %, 6.5 ml min(-1)), and passed through the flow through cell of spectrophotometer where its absorbance was measured at 653 nm. Various parameters affecting adsorption and elution of the uranium complex were optimized. For data analyses peak absorbance was used. For 60 and 180 s preconcentration time, enrichment factors (EF) 20 and 40, sampling frequency (SF) 45 and 18 h(-1); and detection limits (DL) (3 sigma) 14.2 and 8.6 mu g l(-1) were obtained, respectively. To enhance the sensitivity of the system, two minicolumns (described above) were used for simultaneous preconcentration and elution purpose. For 60 and 180 s preconcentration time, EF 30 and 50, SF 42 and 17 h(-1) and DL (3 sigma) 4.4 and 3.44 mu g l(-1) were obtained, respectively. The effect of various anions and cations was studied for single column manifold. High selectivity of this method was observed. All the anions and cations studied did not interfere up to 330 times higher mass ratio to 300 mu g l(-1) U (VI) except Th(IV) which was tolerated up to 133 times by the addition of washing step in the manifold. The method based on single column manifold was applied on the spiked tap water, biological sample CRM (IAEA-V4) and synthetic leach liquor solution and good recovery was obtained. The method based on dual column manifold was validated on lake sediment SL-1 (CRM) and the results obtained were in good agreement at 95 % confidence level with the given value.
引用
收藏
页码:2203 / 2214
页数:12
相关论文
共 50 条
  • [1] FI-spectrophotometric determination of uranium after preconcentration on an anion exchange resin
    Qamar un Nisa
    Akbar Ali
    Muhammad Haleem Khan
    Journal of Radioanalytical and Nuclear Chemistry, 2013, 295 : 2203 - 2214
  • [2] Flow injection online spectrophotometric determination of uranium after preconcentration on XAD-4 resin impregnated with nalidixic acid
    Shahida, Shabnam
    Ali, Akbar
    Khan, Muhammad Haleem
    Saeed, Muhammad Mufazzal
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2013, 185 (02) : 1613 - 1626
  • [3] Flow injection on-line determination of uranium after preconcentration on XAD-4 resin impregnated with dibenzoylmethane
    Shahida, Shabnam
    Ali, Akbar
    Khan, Muhammad Haleem
    Saeed, Muhammad Mufazzal
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2011, 289 (03) : 929 - 938
  • [4] Determination of uranium in seawater by flow-injection preconcentration on dodecylamidoxime-impregnated resin and spectrophotometric detection
    Oguma, Koichi
    Suzuki, Toshihiro
    Saito, Kyoichi
    TALANTA, 2011, 84 (05) : 1209 - 1214
  • [5] Flow injection online spectrophotometric determination of uranium after preconcentration on XAD-4 resin impregnated with nalidixic acid
    Shabnam Shahida
    Akbar Ali
    Muhammad Haleem Khan
    Muhammad Mufazzal Saeed
    Environmental Monitoring and Assessment, 2013, 185 : 1613 - 1626
  • [6] Online thorium determination after preconcentration in a minicolumn having XAD-4 resin impregnated with N-benzoylphenylhydroxylamine by FI-spectrophotometry
    Ali, Akbar
    Shahida, Shabnam
    Khan, Muhammad Haleem
    Saeed, Muhammad Mufazzal
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2011, 288 (03) : 735 - 743
  • [7] FLOW-INJECTION SPECTROPHOTOMETRIC DETERMINATION OF URANIUM WITH IN-VALVE ION-EXCHANGE COLUMN PRECONCENTRATION AND SEPARATION
    GRUDPAN, K
    LAIWRAUNGRATH, S
    SOOKSAMITI, P
    ANALYST, 1995, 120 (08) : 2107 - 2110
  • [8] Anion-exchange separation of interfering iron from liquid samples for accurate determination of uranium by spectrophotometric method
    Aziz, Abdul
    Sajjad, Muhammad
    Mohammad, Bashir
    DESALINATION AND WATER TREATMENT, 2017, 58 : 449 - 453
  • [9] On-line spectrophotometric determination of scandium after preconcentration on XAD-4 resin impregnated with nalidixic acid
    Shahida, Shabnam
    Ali, Akbar
    Khan, Muhammad Haleem
    JOURNAL OF THE IRANIAN CHEMICAL SOCIETY, 2013, 10 (03) : 461 - 470
  • [10] Micelle-mediated preconcentration using cationic surfactants for the spectrophotometric determination of uranium in aqueous solutions
    Zeinab Farouk Akl
    Journal of Radioanalytical and Nuclear Chemistry, 2016, 308 : 693 - 700