Multiangle Long-Axis Lateral Illumination Photoacoustic Imaging Using Linear Array Transducer

被引:10
作者
Uliana, Joao H. [1 ]
Sampaio, Diego R. T. [1 ]
Fernandes, Guilherme S. P. [1 ]
Brassesco, Maria S. [2 ]
Nogueira-Barbosa, Marcello H. [3 ]
Carneiro, Antonio A. O. [1 ]
Pavan, Theo Z. [1 ]
机构
[1] Univ Sao Paulo, Dept Phys, FFCLRP, BR-14040901 Ribeirao Preto, SP, Brazil
[2] Univ Sao Paulo, Dept Biol, FFCLRP, BR-14040901 Ribeirao Preto, SP, Brazil
[3] Univ Sao Paulo, Ribeirao Preto Med Sch, Dept Med Images Hematol & Clin Oncol, BR-14040901 Ribeirao Preto, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
photoacoustic imaging; illumination scheme; in vivo; mouse; Monte Carlo; linear array; HAND-HELD PROBE; LIGHT DELIVERY; OXYGEN-SATURATION; HIGH-RESOLUTION; TOMOGRAPHY; ULTRASOUND; SYSTEM; SPECTROSCOPY; CONTRAST;
D O I
10.3390/s20144052
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Photoacoustic imaging (PAI) combines optical contrast with ultrasound spatial resolution and can be obtained up to a depth of a few centimeters. Hand-held PAI systems using linear array usually operate in reflection mode using a dark-field illumination scheme, where the optical fiber output is attached to both sides of the elevation plane (short-axis) of the transducer. More recently, bright-field strategies where the optical illumination is coaxial with acoustic detection have been proposed to overcome some limitations of the standard dark-field approach. In this paper, a novel multiangle long-axis lateral illumination is proposed. Monte Carlo simulations were conducted to evaluate light delivery for three different illumination schemes: bright-field, standard dark-field, and long-axis lateral illumination. Long-axis lateral illumination showed remarkable improvement in light delivery for targets with a width smaller than the transducer lateral dimension. A prototype was developed to experimentally demonstrate the feasibility of the proposed approach. In this device, the fiber bundle terminal ends are attached to both sides of the transducer's long-axis and the illumination angle of each fiber bundle can be independently controlled. The final PA image is obtained by the coherent sum of subframes acquired using different angles. The prototype was experimentally evaluated by taking images from a phantom, a mouse abdomen, forearm, and index finger of a volunteer. The system provided light delivery enhancement taking advantage of the geometry of the target, achieving sufficient signal-to-noise ratio at clinically relevant depths.
引用
收藏
页码:1 / 19
页数:19
相关论文
共 67 条
[1]   Photoacoustic Clutter Reduction Using Short-Lag Spatial Coherence Weighted Imaging [J].
Alles, Erwin J. ;
Jaeger, Michael ;
Bamber, Jeffrey C. .
2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2014, :41-44
[2]   Compact and low-cost handheld quasibright-field linear-array probe design in photoacoustic computed tomography [J].
Bai, Yuanyuan ;
Cong, Bing ;
Gong, Xiaojing ;
Song, Liang ;
Liu, Chengbo .
JOURNAL OF BIOMEDICAL OPTICS, 2018, 23 (12)
[3]   Biomedical photoacoustic imaging [J].
Beard, Paul .
INTERFACE FOCUS, 2011, 1 (04) :602-631
[4]  
Bushberg J.T., 2011, ESSENTIAL PHYS MED I
[5]   PHOTOACOUSTIC PROBE FOR INTRAARTERIAL IMAGING AND THERAPY [J].
CHEN, QX ;
DAVIES, A ;
DEWHURST, RJ ;
PAYNE, PA .
ELECTRONICS LETTERS, 1993, 29 (18) :1632-1633
[6]   In vivo detection of hemoglobin oxygen saturation and carboxyhemoglobin saturation with multiwavelength photoacoustic microscopy [J].
Chen, Zhongjiang ;
Yang, Sihua ;
Xing, Da .
OPTICS LETTERS, 2012, 37 (16) :3414-3416
[7]   Clinical photoacoustic imaging platforms [J].
Choi W. ;
Park E.-Y. ;
Jeon S. ;
Kim C. .
Biomedical Engineering Letters, 2018, 8 (02) :139-155
[8]  
Cook M.J., 1965, ANATOMY LAB MOUSE
[9]   Handheld probe integrating laser diode and ultrasound transducer array for ultrasound/photoacoustic dual modality imaging [J].
Daoudi, K. ;
van den Berg, P. J. ;
Rabot, O. ;
Kohl, A. ;
Tisserand, S. ;
Brands, P. ;
Steenbergen, W. .
OPTICS EXPRESS, 2014, 22 (21) :26365-26374
[10]   Monte Carlo Simulation of Photon Migration in 3D Turbid Media Accelerated by Graphics Processing Units [J].
Fang, Qianqian ;
Boas, David A. .
OPTICS EXPRESS, 2009, 17 (22) :20178-20190