Total coliform inactivation in natural water by UV/H2O2, UV/US, and UV/US/H2O2 systems

被引:16
|
作者
Rubio-Clemente, Ainhoa [1 ,2 ,3 ]
Chica, Edwin [4 ]
Penuela, Gustavo [2 ]
机构
[1] Univ Catolica Murcia UCAM, Fac Ciencias Salud, Ave Jeronimos S-N, Murcia, Spain
[2] Univ Antioquia UdeA, SIU, Fac Ingn, Grp GDCON, Calle 70,52-21, Medellin, Colombia
[3] Tecnol Antioquia Inst Univ TdeA, Fac Ingn, Calle 78b 72A-220, Medellin, Colombia
[4] Univ Antioquia UdeA, Fac Ingn, Dept Ingn Mecan, Calle 70,52-21, Medellin, Colombia
关键词
Advanced oxidation process; Disinfection; Total coliform; Water treatment; UV/H2O2; system; UV/US process; UV/US/H2O2; ADVANCED OXIDATION PROCESSES; NEUTRAL PHOTO-FENTON; BY-PRODUCT FORMATION; ESCHERICHIA-COLI; WASTE-WATER; UV-C; DISINFECTION PROCESSES; ULTRASOUND; BACTERIA; PHOTOCATALYSIS;
D O I
10.1007/s11356-018-3297-z
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The presence of pathogens in drinking water can seriously affect human health. Therefore, water disinfection is needed, but conventional processes, such as chlorination, result in the production of dangerous disinfection by-products. In this regard, an alternative solution to tackle the problem of bacterial pollution may be the application of advanced oxidation processes. In this work, the inactivation of total coliforms, naturally present in a Colombian surface water by means of UV/H2O2, UV/US, and the UV/US/H2O2 advanced oxidation processes, was investigated. Under the investigated conditions, complete bacterial inactivation (detection limit equal to 1 CFU 100 mL(-1)) was found within 5 min of treatment by UV/H2O2 and UV/US/H2O2 systems. UV/US oxidation process also resulted in total bacterial load elimination, but after 15 min of treatment. Bacterial reactivation after 24 h and 48 h in the dark was measured and no subsequent regrowth was observed. This phenomenon could be attributed to the high oxidation capacity of the evaluated oxidation systems. However, the process resulting in the highest oxidation potential at the lowest operating cost, in terms of energy consumption, was UV/H2O2 system. Therefore, UV/H2O2 advanced oxidation system can be used for disinfection purposes, enabling drinking water production meeting the requirements of regulated parameters in terms of water quality, without incurring extremely high energy costs. Nonetheless, further researches are required for minimizing the associated electric costs.
引用
收藏
页码:4462 / 4473
页数:12
相关论文
共 50 条
  • [1] Total coliform inactivation in natural water by UV/H2O2, UV/US, and UV/US/H2O2 systems
    Ainhoa Rubio-Clemente
    Edwin Chica
    Gustavo Peñuela
    Environmental Science and Pollution Research, 2019, 26 : 4462 - 4473
  • [2] Degradation of Calmagite by H2O2/UV/US, H2O2/US, H2O2, and US process
    Menek, Necati
    Ugurlar, Ceren
    Ucarh, Okan
    Karaman, Yeliz
    Omanovic, Sasha
    Ghasemian, Saloumeh
    ALEXANDRIA ENGINEERING JOURNAL, 2022, 61 (05) : 4127 - 4135
  • [3] Comparative Effect of UV, UV/H2O2 and UV/H2O2/Fe on Terbuthylazine Degradation in Natural and Ultrapure Water
    Antonio Andrades, Jose
    Lojo-Lopez, Manuel
    Egea-Corbacho, Agata
    Maria Quiroga, Jose
    MOLECULES, 2022, 27 (14):
  • [4] Degradation of melatonin by UV, UV/H2O2, Fe2+/H2O2 and UV/Fe2+/H2O2 processes
    Xu, Xiang-Rong
    Li, Xiao-Yan
    Li, Xiang-Zhong
    Li, Hua-Bin
    SEPARATION AND PURIFICATION TECHNOLOGY, 2009, 68 (02) : 261 - 266
  • [5] Comparative Study of Reactive Dyes Oxidation by H2O2/UV, H2O2/UV/Fe2+ and H2O2/UV/Fe° Processes
    Skodic, Lidija
    Vajnhandl, Simona
    Valh, Julija Volmajer
    Zeljko, Tina
    Voncina, Bojana
    Lobnik, Aleksandra
    OZONE-SCIENCE & ENGINEERING, 2017, 39 (01) : 14 - 23
  • [6] A combined degradation of dyes and inactivation of viruses by UV and UV/H2O2
    Timchak, Elena
    Gitis, Vitaly
    CHEMICAL ENGINEERING JOURNAL, 2012, 192 : 164 - 170
  • [7] Degradation of antipyrine by UV, UV/H2O2 and UV/PS
    Tan, Chaoqun
    Gao, Naiyun
    Deng, Yang
    Zhang, Yongji
    Sui, Minghao
    Deng, Jing
    Zhou, Shiqing
    JOURNAL OF HAZARDOUS MATERIALS, 2013, 260 : 1008 - 1016
  • [8] Removal of amoxicillin by UV and UV/H2O2 processes
    Jung, Yeon Jung
    Kim, Wan Gi
    Yoon, Yeojoon
    Kang, Joon-Wun
    Hong, Young Min
    Kim, Hyun Wook
    SCIENCE OF THE TOTAL ENVIRONMENT, 2012, 420 : 160 - 167
  • [9] Pharmaceuticals degradation by UV and UV/H2O2 treatments
    Bozzi, A
    Lopez, A
    Mascolo, G
    Tiravantl, G
    2ND WORLD WATER CONGRESS: DRINKING WATER TREATMENT, 2002, 2 (02): : 19 - 26
  • [10] Kinetics of benzenesulfonates elimination by UV and UV/H2O2
    Mazellier, P
    Rachel, A
    Mambo, W
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 2004, 163 (03) : 389 - 393