The effect of harmonic scalpel, electrocautery, and scalpel use on early wound complications after modified radical mastectomy

被引:15
作者
Anlar, B. [1 ]
Karaman, N. [1 ]
Dogan, L. [1 ]
Ozaslan, C. [1 ]
Atalay, C. [1 ]
Altinok, M. [1 ]
机构
[1] Ankara Oncol Educ & Training Hosp, Dept Gen Surg, Ankara, Turkey
来源
EUROPEAN SURGERY-ACTA CHIRURGICA AUSTRIACA | 2013年 / 45卷 / 06期
关键词
Breast cancer; Mastectomy; Harmonic scalpel; Electrocautery; Complications; SEROMA FORMATION; BREAST-CANCER; AXILLARY DISSECTION; SURGERY; TRIAL;
D O I
10.1007/s10353-013-0231-y
中图分类号
R61 [外科手术学];
学科分类号
摘要
Mastectomy when performed with scalpel and electrocautery is associated with some blood loss and morbidity in the form of prolonged drainage, seroma, wound infection, flap necrosis, and hematoma. A total of 120 patients operated with mastectomy enrolled for the study. The groups were defined by the instruments used for flap preparation: 41 patients operated with electrocautery, 40 patients operated with scalpel, and 39 patients operated with harmonic scalpel formed three groups. The need for closed suction drains, the amount and duration of seroma, surgical site infection, hematoma, and flap ischemia and necrosis were evaluated. The amounts of intraoperative blood loss in electrocautery and harmonic scalpel groups were 560 and 500 mL, respectively, and it was increased to 750 mL in scalpel group (p = 0.001). Total drainage amounts of scalpel and harmonic scalpel groups were 894 and 908 mL, respectively, and it was increased to 1,113 mL in electrocautery group (p = 0.0033). Seroma incidence rates in scalpel, electrocautery, and harmonic scalpel groups were 45, 65 and 28 %, respectively (p = 0.003). The differences between groups in relation to the duration of surgery, breast volume and weight, the areas of flap dissection, the duration of closed suction drainage, and the amount of early drainage were not statistically significant. There was also no difference between groups with regard to hematoma, flap necrosis, and ecchymosis and infection rates. Although the use of harmonic scalpel reduces the risk of seroma formation and intraoperative blood loss, further studies are needed to verify the real impact of such technique.
引用
收藏
页码:286 / 290
页数:5
相关论文
共 22 条
  • [1] Ultracision reduces acute blood loss but not seroma formation after mastectomy and axillary dissection: a pilot study
    Adwani, A
    Ebbs, SR
    [J]. INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2006, 60 (05) : 562 - 564
  • [2] Prospective randomized comparison of conventional instruments and the Harmonic Focus® device in breast-conserving therapy for primary breast cancer
    Boehm, D.
    Kubitza, A.
    Lebrecht, A.
    Schmidt, M.
    Gerhold-Ay, A.
    Battista, M.
    Stewen, K.
    Solbach, C.
    Koelbl, H.
    [J]. EJSO, 2012, 38 (02): : 118 - 124
  • [3] Harmonic Scalpel versus Electrocautery in Breast Reduction Surgery: A Randomized Controlled Trial
    Burdette, Todd E.
    Kerrigan, Carolyn L.
    Homa, Karen A.
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 2011, 128 (04) : 243E - 249E
  • [4] Deo S. V. S., 2002, SMJ Singapore Medical Journal, V43, P226
  • [5] Deo SVS, 2000, J SURG ONCOL, V74, P204, DOI 10.1002/1096-9098(200007)74:3<204::AID-JSO9>3.0.CO
  • [6] 2-U
  • [7] Mastectomy using ultrasonic dissection: effect on seroma formation
    Galatius, H
    Okholm, M
    Hoffmann, J
    [J]. BREAST, 2003, 12 (05) : 338 - 341
  • [8] Gravenstein JS, 1987, CLIN MONITORING PRAC, P340
  • [9] Harmonic Focus Versus Electrocautery in Axillary Lymph Node Dissection for Breast Cancer: A Randomized Clinical Study
    He, Qingqing
    Zhuang, Dayong
    Zheng, Luming
    Fan, Ziyi
    Zhou, Peng
    Zhu, Jian
    Lv, Zhen
    Chai, Jixin
    Cao, Lei
    [J]. CLINICAL BREAST CANCER, 2012, 12 (06) : 454 - 458
  • [10] HOEFER RA, 1990, J AM OSTEOPATH ASSOC, V90, P47