Seismic assessment of interacting structural units in complex historic masonry constructions by nonlinear static analyses

被引:81
作者
Abbati, Stefania Degli [1 ]
D'Altri, Antonio Maria [2 ]
Ottonelli, Dania [1 ]
Castellazzi, Giovanni [2 ]
Cattari, Serena [1 ]
de Miranda, Stefano [2 ]
Lagomarsino, Sergio [1 ]
机构
[1] Univ Genoa, Dept Civil, DICCA, Chem Environm Engn, Via Montallegro 1, I-16145 Genoa, Italy
[2] Univ Bologna, DICAM, Dept Civil Chem Environm & Mat Engn, Viale Risorgimento 2, I-40136 Bologna, Italy
关键词
Interacting structures; Fortresses; Masonry; Seismic assessment; Nonlinear static analyses; Emilia earthquake; FINALE EMILIA; VULNERABILITY ASSESSMENT; DAMAGE ASSESSMENT; TOWERS; BEHAVIOR; MODEL; BUILDINGS; COLLAPSE; CLOCK;
D O I
10.1016/j.compstruc.2018.12.001
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The damage occurred due to past earthquakes highlighted that the seismic behavior of historic masonry structures characterized by an aggregation of units with an own seismic behavior (e.g. palaces, fortresses, castles, etc.) is strongly affected by their dynamic interaction. At present, no codified and operational tools are available to perform the seismic assessment of such mutually interacting structures. This paper introduces a numerical procedure based on the use of nonlinear static analyses to fill this gap. The proposed procedure firstly requires the execution of a modal analysis on the 3D finite element model of the whole structure to define the modes which involve the dynamic response of each unit and their modal shapes. The latter are then fitted to define the load patterns to be applied on each unit through pushover analyses. The pushover curves obtained for each unit are then converted into capacity curves to finalize the seismic assessment. The effectiveness of the proposed procedure is shown through an application to a medieval fortress significantly damaged by the 2012 Emilia earthquake (Italy). The results achieved are promising and support the possible extension of the procedure to other typologies of complex historic structures composed by various interacting units. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:51 / 71
页数:21
相关论文
共 58 条
[1]  
Abaqus, 2014, ABAQUS THEORY MANUAL
[2]   Collapse analysis of the Clock and Fortified towers of Finale Emilia, Italy, after the 2012 Emilia Romagna seismic sequence: Lesson learned and reconstruction hypotheses [J].
Acito, Maurizio ;
Chesi, Claudio ;
Milani, Gabriele ;
Torri, Stefano .
CONSTRUCTION AND BUILDING MATERIALS, 2016, 115 :193-213
[3]   Collapse of the clock tower in Finale Emilia after the May 2012 Emilia Romagna earthquake sequence: Numerical insight [J].
Acito, Maurizio ;
Bocciarelli, Massimiliano ;
Chesi, Claudio ;
Milani, Gabriele .
ENGINEERING STRUCTURES, 2014, 72 :70-91
[4]  
[Anonymous], 2005, EN 1998-3
[5]  
[Anonymous], 2014, 4113 ASCESEI
[6]  
[Anonymous], THESIS
[7]  
[Anonymous], 2013, DEV FIELD DISPLACEME
[8]  
[Anonymous], 2006, P 1 EUR C EARTHQ ENG
[9]   Ambient vibration-based finite element model updating of an earthquake-damaged masonry tower [J].
Bassoli, Elisa ;
Vincenzi, Loris ;
D'Altri, Antonio Maria ;
de Miranda, Stefano ;
Forghieri, Marianna ;
Castellazzi, Giovanni .
STRUCTURAL CONTROL & HEALTH MONITORING, 2018, 25 (05)
[10]   An orthotropic damage model for masonry structures [J].
Berto, L ;
Saetta, A ;
Scotta, R ;
Vitaliani, R .
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN ENGINEERING, 2002, 55 (02) :127-157