Five-Millimeter and Smaller Embryos Without Embryonic Cardiac Activity Outcomes in Women With Vaginal Bleeding

被引:6
作者
Aziz, Seerat [1 ]
Cho, Richard C. [2 ]
Baker, Diana B. [3 ]
Chhor, Chloe [1 ]
Filly, Roy A. [1 ]
机构
[1] Univ Calif San Francisco, Dept Radiol, San Francisco, CA 94143 USA
[2] Moran Rowen & Dorsey Inc, Diagnost Med Imaging, Orange, CA USA
[3] Mills Peninsula Hlth Serv, California Adv Imaging Med Associates, Burlingame, CA USA
关键词
bleeding; embryo; sonography; threatened abortion;
D O I
10.7863/jum.2008.27.11.1559
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective. The purpose of this study was to assess outcomes in embryos with a crown-rump length (CRL) of 5 mm or less without embryonic cardiac activity (ECA) among pregnant women with vaginal bleeding in the first trimester. Methods. A retrospective study of all first-trimester sonograms in women with vaginal bleeding from 1999 to 2002 was conducted. Results. Thirty-seven embryos without detectable ECA that had a CRL of 5 mm or less were identified. All resulted in pregnancy failure. The breakdown of these embryos by CRL was as follows: 13 were 5 mm; 10 ranged from 4 to 4.9 mm; 11 ranged from 3 to 3.9 mm; and 3 ranged from 2 to 2.9 mm. Conclusions. In pregnant women with vaginal bleeding, embryos of 5 mm and smaller without a heartbeat all resulted in pregnancy failure.
引用
收藏
页码:1559 / 1561
页数:3
相关论文
共 10 条
[1]  
BROWN DL, 1990, J ULTRAS MED, V9, P631
[2]   ENDOVAGINAL SONOGRAPHY IN VERY EARLY-PREGNANCY - NEW OBSERVATIONS [J].
GOLDSTEIN, RB .
RADIOLOGY, 1990, 176 (01) :7-8
[3]   The chorionic bump - A first-trimester pregnancy sonographic finding associated with a guarded prognosis [J].
Harris, RD ;
Couto, C ;
Karpovsky, C ;
Porter, MMB ;
Ouhilal, S .
JOURNAL OF ULTRASOUND IN MEDICINE, 2006, 25 (06) :757-763
[4]   ESTABLISHING THE DEATH OF AN EMBRYO BY ULTRASOUND - REPORT OF A PUBLIC INQUIRY WITH RECOMMENDATIONS [J].
HATELY, W ;
CASE, J ;
CAMPBELL, S .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1995, 5 (05) :353-357
[5]   COMPARISON OF TRANS-VAGINAL AND TRANS-ABDOMINAL SONOGRAPHY IN THE DETECTION OF EARLY-PREGNANCY AND ITS COMPLICATIONS [J].
JAIN, KA ;
HAMPER, UM ;
SANDERS, RC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 151 (06) :1139-1143
[6]  
Laing FC, 2008, ULTRASONOGRAPHY OBST, P181
[7]   ENDOVAGINAL US - DEMONSTRATION OF CARDIAC ACTIVITY IN EMBRYOS OF LESS THAN 5.0 MM IN CROWN-RUMP LENGTH [J].
LEVI, CS ;
LYONS, EA ;
ZHENG, XH ;
LINDSAY, DJ ;
HOLT, SC .
RADIOLOGY, 1990, 176 (01) :71-74
[8]  
PENNELL RG, 1991, J ULTRAS MED, V10, P63
[9]   Sonography during early pregnancy: Dependence of threshold and discriminatory values on transvaginal transducer frequency [J].
Rowling, SE ;
Langer, JE ;
Coleman, BG ;
Nisenbaum, HL ;
Horii, SC ;
Arger, PH .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (04) :983-988
[10]  
Schouwink M H, 2000, Early Pregnancy, V4, P203