Rapid diagnosis of central-venous-catheter-related bloodstream infection without catheter removal

被引:113
作者
Kite, P
Dobbins, BM
Wilcox, MH
McMahon, MJ
机构
[1] Univ Leeds, Gen Infirm, Dept Microbiol, Leeds LS1 3EX, W Yorkshire, England
[2] Gen Infirm, Acad Surg Unit, Leeds LS1 3EX, W Yorkshire, England
关键词
D O I
10.1016/S0140-6736(99)04070-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Current methods for the diagnosis of bloodstream infection related to central venous catheters (CVC) are slow and in many cases require catheter removal. Since most CVC that are removed on suspicion of causing infection prove not to be infected, removal of catheters unnecessarily exposes patients to the risks associated with reinsertion. Methods The gram slain and acridine-orange leucocyte cytospin test (AOLC) is rapid (30 min), inexpensive, and requires only 100 mu L catheter blood (treated with edetic acid) and the use of light and ultraviolet microscopy. We assessed the gram stain and AOLC lest in suspected cases of catheter-related bloodstream infection, in comparison with two methods requiring catheter removal (tip roll and tip flush), and a third technique, done in situ (endoluminal brush) in conjunction with quantitative peripheral-blood cultures. Findings 128 cases of suspected catheter-related bloodstream infection were assessed in 124 adult surgical patients (median duration of CVC placement was 16 days). In 112 (88%) cases CVC blood was obtainable. Catheter-related bloodstream infection was diagnosed in 50 cases (culture of the same organism from the catheter, in significant numbers, and from peripheral-blood culture). The sensitivity of the gram stain and AOLC test was 96% and the specificity was 92%, with a positive predictive value of 91% and a negative predictive value of 97%. By comparison, the tip-roll, tip-flush, and endoluminal-brush methods had sensitivities of 90%, 95%, and 92%, and specificities of 55%, 76%, and 98%, respectively. Interpretation The gram stain and AOLC test is a simple, and rapid method for the diagnosis of catheter-related bloodstream infection. This diagnostic method compares favourably with other diagnostic methods, particularly those that require the removal of the catheter, and can permit early targeted antimicrobial therapy.
引用
收藏
页码:1504 / 1507
页数:4
相关论文
共 27 条
  • [1] BANERJEE SN, 1991, AM J MED, V91, pS87
  • [2] Earlier positivity of central-venous- versus peripheral-blood cultures is highly predictive of catheter-related sepsis
    Blot, F
    Schmidt, E
    Nitenberg, G
    Tancrède, C
    Leclercq, B
    Laplanche, A
    Andremont, A
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 1998, 36 (01) : 105 - 109
  • [3] DIAGNOSIS OF CENTRAL VENOUS CATHETER-RELATED SEPSIS - CRITICAL-LEVEL OF QUANTITATIVE TIP CULTURES
    BRUNBUISSON, C
    ABROUK, F
    LEGRAND, P
    HUET, Y
    LARABI, S
    RAPIN, M
    [J]. ARCHIVES OF INTERNAL MEDICINE, 1987, 147 (05) : 873 - 877
  • [4] VALUE OF DIFFERENTIAL QUANTITATIVE BLOOD CULTURES IN THE DIAGNOSIS OF CATHETER-RELATED SEPSIS
    CAPDEVILA, JA
    PLANES, AM
    PALOMAR, M
    GASSER, I
    ALMIRANTE, B
    PAHISSA, A
    CRESPO, E
    MARTINEZVAZQUEZ, JM
    [J]. EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 1992, 11 (05) : 403 - 407
  • [5] QUANTITATIVE CULTURE OF INTRAVENOUS CATHETERS AND OTHER INTRAVASCULAR INSERTS
    CLERI, DJ
    CORRADO, ML
    SELIGMAN, SJ
    [J]. JOURNAL OF INFECTIOUS DISEASES, 1980, 141 (06) : 781 - 787
  • [6] A comparison of two antimicrobial-impregnated central venous catheters
    Darouiche, RO
    Raad, II
    Heard, SO
    Thornby, JI
    Wenker, OC
    Gabrielli, A
    Berg, J
    Khardori, N
    Hanna, H
    Hachem, R
    Harris, RL
    Mayhall, G
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1999, 340 (01) : 1 - 8
  • [7] Diagnosis of central venous catheter related sepsis - a critical look inside
    Dobbins, BM
    Kite, P
    Wilcox, MH
    [J]. JOURNAL OF CLINICAL PATHOLOGY, 1999, 52 (03) : 165 - 172
  • [8] Evaluation of a novel endoluminal brush method for in situ diagnosis of catheter related sepsis
    Kite, P
    Dobbins, BM
    Wilcox, MH
    Fawley, WN
    Kindon, AJL
    Thomas, D
    Tighe, MJ
    McMahon, MJ
    [J]. JOURNAL OF CLINICAL PATHOLOGY, 1997, 50 (04) : 278 - 282
  • [9] Maki Dennis G., 1994, P155
  • [10] AN ATTACHABLE SILVER-IMPREGNATED CUFF FOR PREVENTION OF INFECTION WITH CENTRAL VENOUS CATHETERS - A PROSPECTIVE RANDOMIZED MULTICENTER TRIAL
    MAKI, DG
    COBB, L
    GARMAN, JK
    SHAPIRO, JM
    RINGER, M
    HELGERSON, RB
    [J]. AMERICAN JOURNAL OF MEDICINE, 1988, 85 (03) : 307 - 314