Tuneable Microsecond-Pulsed Glow Discharge Design for the Simultaneous Acquisition of Elemental and Molecular Chemical Information Using a Time-of-Flight Mass Spectrometer

被引:21
作者
Sola-Vazquez, Auristela [1 ]
Martin, Antonio [1 ]
Costa-Fernandez, Jose M. [1 ]
Pereiro, Rosario [1 ]
Sanz-Medel, Alfredo [1 ]
机构
[1] Univ Oviedo, Dept Phys & Analyt Chem, Fac Chem, E-33006 Oviedo, Spain
关键词
DIRECT SOLID ANALYSIS; GAS-CHROMATOGRAPHY; IONIZATION SOURCE; SPECIATION; QUANTIFICATION; PARAMETERS;
D O I
10.1021/ac802520q
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A microsecond-pulsed direct current glow discharge (GD) was interfaced and synchronized to a time-of-flight mass spectrometer MS(TOF) for time-gated generation and detection of elemental, structural, and molecular ions. In this way, sequential collection of the mass spectra at different temporal regimes occurring during the GD pulse cycle is allowed. The capabilities of this setup were explored using bromochloromethane as model analyte. A simple GD chamber, developed in our laboratory and characterized by a low plasma volume minimizing dilution of the sample but showing great robustness to the entrance of organic compounds in the microsecond-pulsed plasma, has been used. An exhaustive analytical characterization of the GD-MS(TOF) prototype has been performed. Calibration curves for bromochloromethane observed at the different time regimes of the GD pulse cycle (that is, for elemental, fragment, and molecular ions from the analyte) showed very good linearity for the measurement of the different involved ions, with precisions in the range of 7-13% (relative standard deviation). Actual detection limits obtained for bromochloromethane were in the range of 1-3 mu g/L for elements monitoring in the GD pulse "prepeak", in the range of 11 - 13 mu g/L when monitoring analyte fragments in the plateau, and about 238 mu g/L when measuring the molecular peak in the afterpeak regime.
引用
收藏
页码:2591 / 2599
页数:9
相关论文
共 23 条
[11]   Tunable plasma sources in analytical spectroscopy: Current status and projections [J].
Marcus, RK ;
Evans, EH ;
Caruso, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (01) :1-5
[12]   Microsecond pulsed versus direct current glow discharge as ion sources for analytical glow discharge-time of ight mass spectrometry [J].
Martin, Antonio ;
Pereiro, Rosario ;
Bordel, Nerea ;
Sanz-Medel, Alfredo .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2007, 22 (09) :1179-1183
[13]   A radiofrequency glow-discharge-time-of-flight mass spectrometer for direct analysis of glasses [J].
Pisonero, J ;
Costa, JM ;
Pereiro, R ;
Bordel, N ;
Sanz-Medel, A .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 379 (04) :658-667
[14]   A simple glow discharge ion source for direct solid analysis by on-axis time-of-flight mass spectrometry [J].
Pisonero, J ;
Costa, JM ;
Pereiro, R ;
Bordel, N ;
Sanz-Medel, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (11) :1253-1258
[15]   Further development of a simple glow discharge source for direct solid analysis by on-axis time of flight mass spectrometry [J].
Pisonero-Castro, J ;
Costa-Fernández, JM ;
Pereiro, R ;
Bordel, N ;
Sanz-Medel, A .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (08) :786-789
[16]   Plasma-source mass spectrometry for speciation analysis: state-of-the-art [J].
Ray, SJ ;
Andrade, F ;
Gamez, G ;
McClenathan, D ;
Rogers, D ;
Schilling, G ;
Wetzel, W ;
Hieftje, GM .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1050 (01) :3-34
[17]   Microwave plasma torch - atmospheric-sampling glow discharge modulated tandem source for the sequential acquisition of molecular fragmentation and atomic mass spectra [J].
Ray, SJ ;
Hieftje, GM .
ANALYTICA CHIMICA ACTA, 2001, 445 (01) :35-45
[18]   Trace element analytical speciation in biological systems: importance, challenges and trends [J].
Sanz-Medel, A .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (02) :197-211
[19]   Heteroatom(isotope)-tagged proteomics via ICP-MS: screening and quantification of proteins and their post-translational modifications [J].
Sanz-Medel, Alfredo .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 391 (03) :885-894
[20]   Consideration of a millisecond pulsed glow discharge time-of-flight mass spectrometer for concurrent elemental and molecular analysis [J].
Steiner, RE ;
Lewis, CL ;
Majidi, V .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (09) :1537-1541