A critical evaluation of the material properties and clinical suitability of in-house printed and commercial tooth replicas for endodontic training

被引:31
作者
Reymus, M. [1 ]
Stawarczyk, B. [2 ]
Winkler, A. [3 ]
Ludwig, J. [3 ]
Kess, S. [4 ]
Krastl, G. [3 ]
Krug, R. [3 ]
机构
[1] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Conservat Dent & Periodontol, Goethestr 70, D-80336 Munich, Germany
[2] Ludwig Maximilians Univ Munchen, Univ Hosp, Dept Prosthet Dent, Munich, Germany
[3] Julius Maximilians Univ, Univ Hosp, Dept Conservat Dent, Wurzburg, Germany
[4] Julius Maximilians Univ, Univ Hosp, Dept Orthodont, Wurzburg, Germany
关键词
3D Printing; dental education; replica; undergraduate training; TEETH; RADIOPACITY; ACCURACY;
D O I
10.1111/iej.13361
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim To assess the suitability of several 3D-printed resins for the manufacturing of tooth replicas for endodontic training in comparison with commercially available replicas by analysing the properties of the materials and comparing them with real teeth during endodontic training. Methodology Tooth replicas were 3D-printed using four resins (NextDent Model, NextDent C&B, V-Print ee and Vero White Plus) and compared with two commercially available products (VDW and Smile Factory) as well as extracted human teeth. Martens hardness, indentation modulus and radiopacity were investigated on these tooth replicas. Experienced dentists evaluated the suitability of the replicas for endodontic training by comparing them with real teeth in terms of appearance, anatomy, radiopacity, similarity to dentine during access opening, canal gauging and canal instrumentation. Data were analysed using the Kolmogorov-Smirnov and Mann-WhitneyU-test. Results The greatest hardness values were recorded for human dentine (P < 0.001), followed by V-Print ee and the commercial tooth replica of Smile Factory. The greatest radiopacity was associated with VOC and dentine (P < 0.001) in comparison with the other materials tested. The appearance of the in-house printed tooth replicas was subjectively evaluated by the dentists as being more realistic than the commercially available products. No differences between the replicas was detected during mechanical instrumentation of root canals. Conclusion None of the tooth replicas were able to simulate human dentine from the perspectives evaluated. V-Print ee had radiopacity comparable with dentine, but its hardness was not comparable with dentine.
引用
收藏
页码:1446 / 1454
页数:9
相关论文
共 25 条
[1]  
Al-Sudani D, 2017, EUROPEAN J DENT ED, V21, P72
[2]   Radiopacity of contemporary luting cements using conventional and digital radiography [J].
An, Seo-Young ;
An, Chang-Hyeon ;
Choi, Karp-Sik ;
Huh, Kyung-Hoe ;
Yi, Won-Jin ;
Heo, Min-Suk ;
Lee, Sam-Sun ;
Choi, Soon-Chul .
IMAGING SCIENCE IN DENTISTRY, 2018, 48 (02) :97-101
[3]   Artificial Versus Natural Teeth for Preclinical Endodontic Training: A Randomized Controlled Trial [J].
Bitter, Kerstin ;
Gruner, Deborah ;
Wolf, Olivia ;
Schwendicke, Falk .
JOURNAL OF ENDODONTICS, 2016, 42 (08) :1212-1217
[4]   The use of extracted teeth for in vitro bonding studies: A review of infection control considerations [J].
DeWald, JP .
DENTAL MATERIALS, 1997, 13 (02) :74-81
[5]   Radiopacity of composite dental materials using a digital X-ray system [J].
Dukic, Walter ;
Delija, Barbara ;
Derossi, Doria ;
Dadic, Ivana .
DENTAL MATERIALS JOURNAL, 2012, 31 (01) :47-53
[6]   Suitability of different tooth replicas for endodontic training: perceptions and detection of common errors in the performance of postgraduate students [J].
Gancedo-Caravia, L. ;
Bascones, J. ;
Garcia-Barbero, E. ;
Arias, A. .
INTERNATIONAL ENDODONTIC JOURNAL, 2020, 53 (04) :562-572
[7]   Critical analysis of artificial teeth for endodontic teaching [J].
Giazzi Nassri, Maria Renata ;
Carlik, Jaime ;
Nepomuceno da Silva, Camila Roberta ;
Okagawa, Renata Elisa ;
Lin, Suzy .
JOURNAL OF APPLIED ORAL SCIENCE, 2008, 16 (01) :43-49
[8]  
Greaves GN, 2011, NAT MATER, V10, P823, DOI [10.1038/NMAT3134, 10.1038/nmat3134]
[9]   Radiopacity of dental materials using a digital X-ray system [J].
Gu, Steven ;
Rasimick, Brian J. ;
Deutsch, Allan S. ;
Musikant, Barry Lee .
DENTAL MATERIALS, 2006, 22 (08) :765-770
[10]   Accuracy and reproducibility of dental replica models reconstructed by different rapid prototyping techniques [J].
Hazeveld, Aletta ;
Slater, James J. R. Huddleston ;
Ren, Yijin .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2014, 145 (01) :108-115