Utility of intraoperative neural response telemetry in pediatric cochlear implants

被引:4
作者
Sawaf, Tuleen [1 ]
Vovos, Rachel [2 ]
Hadford, Stephen [2 ]
Woodson, Erika [2 ]
Anne, Samantha [2 ,3 ]
机构
[1] Case Western Reserve Univ, Sch Med, 9501 Euclid Ave, Cleveland, OH 44106 USA
[2] Cleveland Clin, Head & Neck Inst, 9500 Euclid Ave, Cleveland, OH 44995 USA
[3] 9500 Euclid Ave A71, Cleveland, OH 44195 USA
关键词
Cochlear implant; Neural response telemetry; ECAP; MAP; COMPOUND ACTION-POTENTIALS; ELECTRODE IMPEDANCE; STIMULATION LEVELS; C-LEVELS; CHILDREN; THRESHOLDS; LANGUAGE; TIME; DISABILITIES; PERFORMANCE;
D O I
10.1016/j.ijporl.2022.111298
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objective: The objective of this study is to evaluate the relationship between intraoperative neural response telemetry (NRT) and postoperative Threshold (T) and Comfort (C) levels and their correlation over time after cochlear implantation (CI). Methods: A retrospective chart review was conducted of patients less than 18 years of age who had CI with a CochlearTM device and NRT at an academic center from 2010 to 2019. Data collected included demographics, extrapolated NRT threshold (tNRT) and slope of amplitude for electrodes 1, 6/7, 11/12, 16, and 22, and post-operative T and C levels at initial activation and 1 month, 3 months, and 1 year post-activation. Associations between T and C levels and slope of amplitude or tNRT were assessed using Spearman's rank correlation. Results: 39 patients (65 CIs) were included. Intraoperative tNRT correlated strongly with T and C levels at 1 month, 3 months, and 1 year post-activation on nearly all electrodes. Electrodes 6/7 and 11/12 at 3 months and electrodes 6/7 at 1 year did not correlate with T and C levels. There was no significant relationship between the slope of amplitude for nearly all electrodes and the T or C levels post-activation. Conclusion: NRT is invaluable in children, with significant correlation found between tNRT and T and C levels over time on nearly all electrodes. There are changes in T and C levels in electrodes 6/7 and 11/12 over time, and close surveillance is beneficial to tailor programming as needed.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Exponential fitting of spread of excitation response measurements in cochlear implants
    Rader, Tobias
    Nachtigaeller, Pascal
    Linke, Theresa
    Weissgerber, Tobias
    Baumann, Uwe
    JOURNAL OF NEUROSCIENCE METHODS, 2023, 391
  • [42] Pediatric cochlear implants and myringotomy tubes: a systematic review
    Patel, Shubham
    Robbins, Alexa
    Tey, Ching Siong
    Zhang, Chao
    Peterson, Shenita
    Govil, Nandini
    COCHLEAR IMPLANTS INTERNATIONAL, 2023, 24 (04) : 216 - 223
  • [43] Use of neural response telemetry measures to objectively set the comfort levels in the nucleus 24 cochlear implant
    King, John E.
    Polak, Marek
    Hodges, Annelle V.
    Payne, Stacy
    Telischi, Fred F.
    JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2006, 17 (06) : 413 - 431
  • [44] Pediatric Cochlear Implants in Prelingual Deafness: Medium and Long-Term Outcomes
    Kaplan, Daniel M.
    Puterman, Moshe
    ISRAEL MEDICAL ASSOCIATION JOURNAL, 2010, 12 (02): : 107 - 109
  • [45] Efficacy of using NRT thresholds in cochlear implants fitting,in prelingual pediatric patients
    Ahmed Allam
    Ahmed Eldegwi
    Journal of Otology, 2019, 14 (04) : 128 - 135
  • [46] Efficacy of using NRT thresholds in cochlear implants fitting, in prelingual pediatric patients
    Allam, Ahmed
    Eldegwi, Ahmed
    JOURNAL OF OTOLOGY, 2019, 14 (04) : 128 - 135
  • [47] Long-Term Reliability of Pediatric Cochlear Implants
    Soli, Sigfrid D.
    Zheng, Yun
    OTOLOGY & NEUROTOLOGY, 2010, 31 (06) : 899 - 901
  • [48] Tone perception and production in pediatric cochlear implants users
    Xu, Li
    Chen, Xiuwu
    Lu, Hongyun
    Zhou, Ning
    Wang, Shuo
    Liu, Qiaoyun
    Li, Yongxin
    Zhao, Xiaoyan
    Han, Demin
    ACTA OTO-LARYNGOLOGICA, 2011, 131 (04) : 395 - 398
  • [49] Cost-utility analysis of cochlear implants in Korea using different measures of utility
    Lee, Hoo-Yeon
    Park, Eun-Cheol
    Kim, Han Joong
    Choi, Jae-Young
    Kim, Hee-Nam
    ACTA OTO-LARYNGOLOGICA, 2006, 126 (08) : 817 - 823
  • [50] The effect of cochlear implant insertion technique on post-operative neural response telemetry and impedance in paediatric patients
    Hashemi, S. B.
    Janipour, M.
    Jahangiri, R.
    Babaei, A.
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2023, 137 (04) : 363 - 367