Studies of radiation fields of LCLS-II super conducting radio frequency cavities

被引:9
作者
Leitner, M. Santana [1 ]
Ge, L. [2 ]
Li, Z. [2 ]
Xu, C. [2 ]
Adolphsen, C. [2 ]
Ross, M. [2 ]
Carrasco, M. [2 ]
机构
[1] SLAC Natl Accelerator Lab, Radiat Protect Dept, 2575 Sand Hill Rd, Menlo Pk, CA 94025 USA
[2] SLAC Natl Accelerator Lab, 2575 Sand Hill Rd, Menlo Pk, CA 94025 USA
来源
PROCEEDINGS OF THE 2015 INTERNATIONAL CONFERENCE ON APPLICATIONS OF NUCLEAR TECHNIQUES (CRETE15) | 2016年 / 44卷
关键词
LCLS-II; Field Emission; SCRF; Cryomodule; Radiation; Track3P; FLUKA; ILC;
D O I
10.1142/S201019451660209X
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The Linac Coherent Light Source II (LCLS-II) will be a hard X-ray Free Electron Laser whose linac can deliver a 1.2 MW CW electron beam with bunch rates up to 1 MHz. To efficiently generate such a high power beam, Super-Conducting Radio-Frequency (SCRF) cavities will be installed in the upstream portion of the existing 3 km Linac at the SLAC National Accelerator Laboratory. The 9-cell niobium cavities will be cooled at 2K inside 35 cryomodules, each containing a string of eight of those cavities followed by a quadrupole. The strong electromagnetic fields in the SCRF cavities will extract electrons from the cavity walls that may be accelerated. Most such dark current will be deposited locally, although some electrons may reach several neighboring cryomodules, gaining substantial energy before they hit a collimator or other aperture. The power deposited by the field emitted electrons and the associated showers may pose radiation and machine protection issues at the cryomodules and also in other areas of the accelerator. Simulation of these effects is therefore crucial for the design of the machine. The in-house code Track3P was used to simulate field emitted electrons from the LCLS-II cavities, and a sophisticated 3D model of the cryomodules including all cavities was written to transport radiation with the Fluka Monte Carlo code, which was linked to Track3P through custom-made routines. This setup was used to compute power deposition in components, prompt and residual radiation fields, and radioisotope inventories.
引用
收藏
页数:10
相关论文
共 13 条
[1]  
Akasaka N., 1996, 9665 KEP
[2]  
Balandin V., 2003, 200310 TESLA
[3]   The FLUKA Code: Developments and Challenges for High Energy and Medical Applications [J].
Boehlen, T. T. ;
Cerutti, F. ;
Chin, M. P. W. ;
Fosso, A. ;
Ferrari, A. ;
Ortega, P. G. ;
Mairani, A. ;
Sala, P. R. ;
Smirnov, G. ;
Vlachoudisl, V. .
NUCLEAR DATA SHEETS, 2014, 120 :211-214
[4]  
Dhanaraj N., FERMILABTM2419APCTD
[5]  
Ferrari A., 2005, CERN2005010, DOI [10.2172/877507, DOI 10.2172/877507]
[6]  
Fouaidy M., 2005, P 12 INT WORKSH RF S
[7]   Electron emission in intense electric fields [J].
Fowler, RH ;
Nordheim, L .
PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-CONTAINING PAPERS OF A MATHEMATICAL AND PHYSICAL CHARACTER, 1928, 119 (781) :173-181
[8]  
Hanks C.L., NASACR1787
[9]  
Kneisel P., 2005, CAVITY PREPARATION T
[10]  
Ko K., 2006, P SCIDAC 2006 C DENV