Performance of a New 235 nm UV-LED-Based On-Capillary Photometric Detector

被引:54
|
作者
Li, Yan [1 ,2 ]
Nesterenko, Pavel N. [1 ,2 ]
Paull, Brett [1 ,2 ]
Stanley, Roger [3 ]
Macka, Mirek [1 ,2 ]
机构
[1] Univ Tasmania, Sch Phys Sci, Hobart, Tas 7001, Australia
[2] Univ Tasmania, ACROSS, Hobart, Tas 7001, Australia
[3] Univ Tasmania, Ctr Food Innovat, Locked Bag 1370, Launceston, Tas 7250, Australia
基金
澳大利亚研究理事会;
关键词
LIGHT-EMITTING-DIODES; FLOW-INJECTION ANALYSIS; DEEP-ULTRAVIOLET RANGE; LIQUID-CHROMATOGRAPHY; ION CHROMATOGRAPHY; ABSORBENCY DETECTOR; EFFECTIVE PATHLENGTH; ABSORPTION DETECTOR; ELECTROPHORESIS; IODIDE;
D O I
10.1021/acs.analchem.6b02832
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, for the first time, a sub-250 nm light-emitting diode (LED) is investigated as a light source for optical detection in chemical analysis. A 235 nm deep ultraviolet-light-emitting diode (UV-LED) is employed within an on-capillary photometric detector and applied in capillary ion-exchange chromatography (IEC) for the detection of common ultraviolet (UV)-absorbing anions (here, iodide, nitrate, and nitrite). This investigation focused on fundamental properties of UV-LEDs, in particular, emission spectra, radiometric power, effective heat dissipation with a passive heat sink, and energy conversion. The detection showed excellent linearity with stray light down to 0.6%, and an effective path length at 92% of the used capillary inner diameter. The analytical performance parameters were demonstrated by detection of chromatographic separation of iodide in simulated seawater, showing a limit of detection (LOD) of 1.30 mu mol L-1, a linear range of 7.9-3937 mu mol L-1, and reproducibility (with a relative standard deviation (RSD)) of 0.6% for peak height 0.7% for peak area. In addition, nitrite and nitrate were selected to study the potential of using deep UV-LEDs as the light source in photometric detection for even lower-wavelength-absorbing analytes (lambda(max) = 209 nm for nitrite and 200 nm for nitrate), showing reproducibility (RSD = 1.2% and 3.6% for peak height and 0.9% and 2.9% for peak area, respectively) and LOD = 7 and 26 mu mol L-1.
引用
收藏
页码:12116 / 12121
页数:6
相关论文
共 50 条
  • [1] Deep-UV-LEDs in photometric detection: A 255 nm LED on-capillary detector in capillary electrophoresis
    Krcmova, Lenka
    Stjernlof, Anna
    Mehlen, Sebastien
    Hauser, Peter C.
    Abele, Silvija
    Paull, Brett
    Macka, Mirek
    ANALYST, 2009, 134 (12) : 2394 - 2396
  • [2] Miniature Multiwavelength Deep UV-LED-Based Absorption Detection System for Capillary LC
    Hemida, Mohamed
    Coates, Lewellwyn Joseph
    Lam, Shing
    Gupta, Vipul
    Macka, Mirek
    Wirth, Hans-Jurgen
    Gooley, Andrew A.
    Haddad, Paul R.
    Paull, Brett
    ANALYTICAL CHEMISTRY, 2020, 92 (20) : 13688 - 13693
  • [3] A New Capillary Electrophoresis Device with Deep UV Detector Based on LED Technology
    Rohrbasser, Claude
    Rheme, Dominique
    Decastel, Sylvain
    Roth, Samuel
    Montes, Maria de Lourdes Aja
    Veuthey, Jean-Luc
    Rudaz, Serge
    CHIMIA, 2009, 63 (12) : 890 - 891
  • [4] Feature size below 100 nm realized by UV-LED-based microscope projection photolithography
    Zheng, Lei
    Birr, Tobias
    Zywietz, Urs
    Reinhardt, Carsten
    Roth, Bernhard
    LIGHT-ADVANCED MANUFACTURING, 2023, 4 (04): : 410 - 419
  • [5] 3D printed LED based on-capillary detector housing with integrated slit
    Cecil, Farhan
    Zhang, Min
    Guijt, Rosanne M.
    Henderson, Alan
    Nesterenko, Pavel N.
    Paull, Brett
    Breadmore, Michael C.
    Macka, Mirek
    ANALYTICA CHIMICA ACTA, 2017, 965 : 131 - 136
  • [6] High sensitivity deep-UV LED-based z-cell photometric detector for capillary liquid chromatography
    Li, Yan
    Nesterenko, Pavel N.
    Stanley, Roger
    Paull, Brett
    Macka, Mirek
    ANALYTICA CHIMICA ACTA, 2018, 1032 : 197 - 202
  • [7] 3D printed two-in-one on-capillary detector: Combining contactless conductometric and photometric detection for capillary electrophoresis
    Yang, Liye
    Pan, Guangchao
    Zhang, Piwang
    Liu, Qiang
    Liu, Xing
    Li, Yan
    Liang, Ying
    Zhang, Min
    ANALYTICA CHIMICA ACTA, 2021, 1159
  • [8] Absorbance detector for high performance liquid chromatography based on a deep-UV light-emitting diode at 235 nm
    Petruci, Joao Flavio da Silveira
    Liebetanz, Michael G.
    Cardoso, Arnaldo Alves
    Hauser, Peter C.
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1512 : 143 - 146
  • [9] Performance of TiO2/UV-LED-Based Processes for Degradation of Pharmaceuticals: Effect of Matrix Composition and Process Variables
    Silva, Danilo Bertagna
    Buttiglieri, Gianluigi
    Babic, Bruna
    Asperger, Danijela
    Babic, Sandra
    NANOMATERIALS, 2022, 12 (02)
  • [10] Capillary electrophoresis with an integrated on-capillary tubular detector based on a carbon sol-gel-derived platform