Low radiation and low-contrast dose pulmonary CT angiography: Comparison of 80 kVp/60 ml and 100 kVp/80 ml protocols

被引:45
|
作者
Viteri-Ramirez, G. [1 ]
Garcia-Lallana, A. [1 ]
Simon-Yarza, I. [1 ]
Broncano, J. [1 ]
Ferreira, M. [1 ]
Pueyo, J. C. [1 ]
Villanueva, A. [1 ]
Bastarrika, G. [1 ]
机构
[1] Univ Navarra Clin, Serv Radiol, Pamplona 31008, Spain
关键词
COMPUTED-TOMOGRAPHY ANGIOGRAPHY; IMAGE QUALITY; IONIZING-RADIATION; MULTIDETECTOR CT; PATIENT WEIGHT; ABDOMINAL CT; BODY-WEIGHT; EMBOLISM; EXPOSURE; ENHANCEMENT;
D O I
10.1016/j.crad.2011.11.016
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To determine the image quality and diagnostic performance of an optimized pulmonary computed tomography angiography (CTA) protocol in terms of radiation and contrast volume saving. MATERIALS AND METHODS: Seventy consecutive patients weighting <= 80 kg with clinical suspicion of pulmonary embolism (PE) were prospectively enrolled. Two pulmonary CTA protocols (group A: n = 35, 80 kV/60 ml; group B: n = 35, 100 kV/80 ml) were compared. The presence of PE, image quality parameters [contrast attenuation, contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR)] and effective radiation dose (mSv) were assessed. RESULTS: PE was found in 11 patients (five of group A, six of group B). The total mean attenuation of the pulmonary arteries was significantly higher in group A (362.4 +/- 100.2 HU) than in group B (262.4 +/- 134.3 HU), whereas the CNR and SNR did not differ statistically (14.8 +/- 7.4 and 16.3 +/- 7.5 for group A and 12.5 +/- 8.6 and 13.8 +/- 9.1 for group B, respectively). The estimated effective radiation dose was significantly lower in group A (1.1 +/- 0.7 mSv) than in group B (2.7 +/- 1.2 mSv). CONCLUSION: In individuals weighting <= 80 kg, the evaluated pulmonary CTA protocol allows similar image quality to be achieved as compared with the conventional pulmonary CIA protocol while reducing radiation exposure by 60% and contrast media volume by 25%. (C) 2012 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:833 / 839
页数:7
相关论文
共 50 条
  • [41] Determination of optimal intravenous contrast agent iodine dose for the detection of liver metastasis at 80-kVp CT
    Goshima, Satoshi
    Kanematsu, Masayuki
    Noda, Yoshifumi
    Kondo, Hiroshi
    Watanabe, Haruo
    Kawada, Hiroshi
    Kawai, Nobuyuki
    Tanahashi, Yukichi
    Bae, Kyongtae T.
    EUROPEAN RADIOLOGY, 2014, 24 (08) : 1853 - 1859
  • [42] Effect of kVp on Noise, Dose, and Contrast-to-Noise Ratio for Pediatric Low-Dose CT
    Gamberoni, J.
    Dong, F.
    Davros, B.
    Reid, J.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05)
  • [43] Diagnostic performance and radiation dose of lower extremity CT angiography using a 128-slice dual source CT at 80 kVp and high pitch
    Kim, Jin Woo
    Choo, Ki Seok
    Jeon, Ung Bae
    Kim, Tae Un
    Hwang, Jae Yeon
    Yeom, Jeong A.
    Jeong, Hee Seok
    Choi, Yoon Young
    Nam, Kyung Jin
    Kim, Chang Won
    Jeong, Dong Wook
    Lim, Soo Jin
    ACTA RADIOLOGICA, 2016, 57 (07) : 822 - 828
  • [44] Impact of iterative reconstructions on image noise and low-contrast object detection in low kVp simulated abdominal CT: a phantom study
    Holmquist, Fredrik
    Nyman, Ulf
    Siemund, Roger
    Geijer, Mats
    Soederberg, Marcus
    ACTA RADIOLOGICA, 2016, 57 (09) : 1079 - 1088
  • [45] Prospectively ECG-triggered high-pitch 80kVp coronary computed tomography angiography with 30mL of 270mg I/mL contrast material and iterative reconstruction
    Qi, Li
    Wu, Sheng Yong
    Meinel, Felix G.
    Zhou, Chang Sheng
    Wang, Qing Qing
    McQuiston, Andrew D.
    Ji, Xue Man
    Schoepf, U. Joseph
    Lu, Guang Ming
    Zhang, Long Jiang
    ACTA RADIOLOGICA, 2016, 57 (03) : 287 - 294
  • [46] Prospective Randomized Comparison of High-pitch CT at 80 kVp Under Free Breathing with Standard-pitch CT at 100 kVp Under Breath-Hold for Detection of Pulmonary Embolism
    Martini, K.
    Meier, A.
    Higashigaito, K.
    Saltybaeva, N.
    Alkadhi, H.
    Frauenfelder, T.
    ACADEMIC RADIOLOGY, 2016, 23 (11) : 1335 - 1341
  • [47] 80-kV Pulmonary CT Angiography With 40 mL of Iodinated Contrast Material in Lean Patients: Comparison of Vascular Enhancement With Iodixanol (320 mg I/mL) and Iomeprol (400 mg I/mL)
    Faggioni, Lorenzo
    Neri, Emanuele
    Sbragia, Paola
    Pascale, Rachele
    D'Errico, Luigia
    Caramella, Davide
    Bartolozzi, Carlo
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (06) : 1220 - 1225
  • [48] Image Quality and Radiation Dose Optimization for High-Resolution Pulmonary CT Angiography Using 100 kVp and Automatic Exposure Control
    Alrajhi, S.
    Alhumayyd, S.
    Blobel, J.
    Kashani, H.
    Odedra, D.
    Roberts, H.
    Narinder, P.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)
  • [49] Cerebral Computed Tomography Angiography Using a Low Tube Voltage (80 kVp) and a Moderate Concentration of Iodine Contrast Material A Quantitative and Qualitative Comparison With Conventional Computed Tomography Angiography
    Cho, Eun-Suk
    Chung, Tae-Sub
    Oh, Dae Kun
    Choi, Hyun Seok
    Suh, Sang Hyun
    Lee, Hyeon-Kyeong
    Lee, Kyung Hee
    INVESTIGATIVE RADIOLOGY, 2012, 47 (02) : 142 - 147
  • [50] Contrast enhancement boost improves the image quality of CT angiography derived from 80-kVp cerebral CT perfusion data
    Yang, Lin
    Zhang, Haiwei
    Sheng, Jiexin
    Wang, Meng
    Liu, Yaliang
    Xu, Min
    Yang, Xiao
    Wang, Bo
    He, Xiaolong
    Gao, Lei
    Zheng, Chao
    BMC MEDICAL IMAGING, 2024, 24 (01):